scholarly journals Practical study on heat pump enhancement by the solar energy

2021 ◽  
Vol 288 ◽  
pp. 01069
Author(s):  
Omar Abdulhadi Mustafa Almohammed ◽  
Farida Mizkhatovna Philippova ◽  
Fouad Ibrahim Alhajj Hassan ◽  
Nail Farilovich Timerbaev ◽  
Anatoliy Anatolyevich Fomin

The heat pumps system is one of the most remarkable system that is widely used around the world, their capacity is different according to necessity. The energy consumption in those systems will limit their effectiveness. This study will try to prove the positive reactance of the new changes (the additional heat exchanger) on the heat pump work, where the power consumption will reduce about (13-17%). The study includes the experimental results of the laboratory model, which has been manufactured in the laboratories of the technical college of Mosul/Northern technical university-Iraq. The model consists of the heat pump that was improved by using the additional heat exchanger, its duty is to heat the refrigerant before entering the compressor, by using solar energy. The results of this work prove the positive effect of the additional heat exchanger, on the coefficient of performance of the heat pump, in both modes of heating and cooling. The conclusions are useful to the industries that deal with heat pumps.

Author(s):  
Mohammad Omar Temori ◽  
František Vranay

In this work, a mini review of heat pumps is presented. The work is intended to introduce a technology that can be used to income energy from the natural environment and thus reduce electricity consumption for heating and cooling. A heat pump is a mechanical device that transfers heat from one environmental compartment to another, typically against a temperature gradient (i.e. from cool to hot). In order to do this, an energy input is required: this may be mechanical, electrical or thermal energy. In most modern heat pumps, electrical energy powers a compressor, which drives a compression - expansion cycle of refrigerant fluid between two heat exchanges: a cold evaporator and a warm condenser. The efficiency or coefficient of performance (COP), of a heat pump is defined as the thermal output divided by the primary energy (electricity) input. The COP decreases as the temperature difference between the cool heat source and the warm heat sink increases. An efficient ground source heat pump (GSHP) may achieve a COP of around 4. Heat pumps are ideal for exploiting low-temperature environmental heat sources: the air, surface waters or the ground. They can deliver significant environmental (CO2) and cost savings.


Energies ◽  
2019 ◽  
Vol 12 (22) ◽  
pp. 4313 ◽  
Author(s):  
Boahen ◽  
Choi

The use of cascade heat pumps for hot water generation has gained much attention in recent times. The big question that has attracted much research interest is how to enhance the performance and energy saving potential of these cascade heat pumps. This study therefore proposed a new cycle to enhance performance of the cascade heat pump by adopting an auxiliary heat exchanger (AHX) in desuperheater, heater and parallel positions at the low stage (LS) side. The new cascade cycle with AHX in desuperheater position was found to have better performance than that with AHX at heater and parallel positions. Compared to the conventional cycle, heating capacity and coefficient of performance (COP) of the new cascade cycle with AHX in desuperheater position increased up to 7.4% and 14.9% respectively.


2011 ◽  
Vol 374-377 ◽  
pp. 398-404 ◽  
Author(s):  
Ying Ning Hu ◽  
Ban Jun Peng ◽  
Shan Shan Hu ◽  
Jun Lin

A hot-water and air-conditioning (HWAC) combined ground sourse heat pump(GSHP) system with horizontal ground heat exchanger self-designed and actualized was presented in this paper. The heat transfer performance for the heat exchanger of two different pipe arrangements, three layers and four layers, respectively, was compared. It showed that the heat exchange quantity per pipe length for the pipe arrangement of three layers and four layers are 18.0 W/m and 15.0 W/m. The coefficient of performance (COP) of unit and system could remain 4.8 and 4.2 as GSHP system for heating water, and the COP of heating and cooling combination are up to 8.5 and 7.5, respectively. The power consumption of hot-water in a whole year is 9.0 kwh/t. The economy and feasibility analysis on vertical and horizontal ground heat exchanger were made, which showed that the investment cost per heat exchange quantity of horizontal ground heat exchanger is 51.4% lower than that of the vertical ground heat exchanger, but the occupied area of the former is 7 times larger than the latter's.


Author(s):  
Li-Xia Wu ◽  
Mao-Yu Zheng

In severely cold climate, significant amount of energy is used to heat buildings. Both the theoretical computation and experiments show that it is difficult and uneconomical to use solar energy collected merely in winter. A new method has been developed to store solar energy during summer, fall, and spring for winter heating. This paper presents in details the combined heating and cooling system by solar ground-source heat pump (GSHP) and short-term phase change material (PCM) thermal storage. The hybrid system and season-shift mode can make the sustainable use of solar energy possible. As for the above system, the solar energy collected is stored into soil through the U-tube heat exchanger. In winter, the thermal energy is taken out for heating using the GSHP. At the end of the heat supply season, the underground soil temperature may drop below 0°C. Then some heat exchangers begin to store the heat into soil while others stop. In summer, the U-tube heat exchanger is used to produce low temperature water without compressor to cool the room. The project was supported by the Energy Conservation Laboratory at Harbin Institute of Technology (HIT). The whole systems, which have run for over two years, consist of a flat plate solar hot water system installed on the roof, a soil thermal storage system, a GSHP system, a PCM thermal storage system and heating-cooling system. The measured results show an average heating coefficient of performance (COP) of 3.2 in winter and the cooling coefficient of performance (COP) of 18.0 in summer. The PCM thermal storage system has been investigated by numerical simulation and experiments in the cold climate. In most time of winter, the PCM thermal storage system was used to supply heat, while solar GSHP was also used during continuous cloudy days and severely cold days. The result shows that above method is feasible. The most advantage of this system is that it does not need the usual energy equipment. The numerical analysis has been used to investigate the thermal energy balance of the underground soil. The variation of the soil temperature field around the U-tube heat exchanger has also been studied, not only for the single exchanger but also for multiple exchangers. The underground soil makes the yearly thermal balance possible because the solar energy supplies the heat that is extracted from the soil for heating in winter. Then this system can operate for a long period.


Energies ◽  
2019 ◽  
Vol 12 (3) ◽  
pp. 364 ◽  
Author(s):  
Marcello Aprile ◽  
Rossano Scoccia ◽  
Alice Dénarié ◽  
Pál Kiss ◽  
Marcell Dombrovszky ◽  
...  

District heating and cooling (DHC), when combined with waste or renewable energy sources, is an environmentally sound alternative to individual heating and cooling systems in buildings. In this work, the theoretical energy and economic performances of a DHC network complemented by compression heat pump and sewage heat exchanger are assessed through dynamic, year-round energy simulations. The proposed system comprises also a water storage and a PV plant. The study stems from the operational experience on a DHC network in Budapest, in which a new sewage heat recovery system is in place and provided the experimental base for assessing main operational parameters of the sewage heat exchanger, like effectiveness, parasitic energy consumption and impact of cleaning. The energy and economic potential is explored for a commercial district in Italy. It is found that the overall seasonal COP and EER are 3.10 and 3.64, while the seasonal COP and EER of the heat pump alone achieve 3.74 and 4.03, respectively. The economic feasibility is investigated by means of the levelized cost of heating and cooling (LCOHC). With an overall LCOHC between 79.1 and 89.9 €/MWh, the proposed system can be an attractive solution with respect to individual heat pumps.


Author(s):  
D A Blank ◽  
C Wu

The optimal cooling and heating rates for the reversed reciprocating Ericsson cycle with ideal regeneration are determined for heat pump operations. These limiting rates are based on the upper and lower thermal reservoir temperature bounds and are obtained using time and entropy minimization procedures from irreversible thermodynamics. Use is made of time symmetry (a second law constraint) to minimize cycle time. This optimally allocates the thermal capacitances of the cycle and minimizes internal cycle entropy generation. Although primarily a theoretical work, a very practical and extensive parametric study using several environmentally friendly working fluids (neon, nitrogen and helium) is included. This study evaluates the relative contributions of various system parameters to rate-optimized design. The coefficient of performance (COP), and thus the quantity of cooling or heating for a given energy input, is the traditional focus; instead this work aims at the rate of cooling or heating in heat pumps under steady state conditions and using ideal gases as their working substances. The results obtained provide additional criteria for use in the study, design and performance evaluation of employing Ericsson cycles in refrigeration, air conditioning and heat pump applications. They give direct insight into what is required in designing a reversed Ericsson heat pump to achieve maximum heating and cooling rates. The choices of working fluids and pressure ratios were found to be very significant design parameters, together with selection of regenerator and source—sink heat transfer parameters. The parameter most influencing both the heating and cooling mode COPs and the heat transfer rates was found to be the heat conductance of the thermal sink.


Energies ◽  
2018 ◽  
Vol 11 (10) ◽  
pp. 2704 ◽  
Author(s):  
Cristina Baglivo ◽  
Sara Bonuso ◽  
Paolo Congedo

A concept of Air-Cooled Heat Pump (ACHP) coupled with a Horizontal Air-Ground Heat Exchanger (HAGHE), also called Horizontal Earth-To-Air Heat Exchanger (EAHX), has been proposed. The Air-Cooled Heat Pump is a system which transfers heat from outside source (air) to inside sink (water) and vice versa in summertime. The innovation is to provide a geothermal treatment of pre-heating/cooling of air before meeting the evaporator in winter or the condenser in summer of the heat pump. Besides, it is known that the variations of the ground temperature, respect to the external air one, are mitigated already in the first layers of the ground throughout the year, due to the high thermal inertia of the ground, letting the heat pump work with more mitigated conditions, improving the performances. The behaviour of HAGHE has been investigated by varying the length and the installation depth of the probes, the air flow rate and the ground thermal properties. All the combinations have been implemented using TRNSYS 17 software (Transient System Simulation Program) to obtain the outlet temperatures from HAGHE, resulting from the 54 configurations. The results are compared in terms of Coefficient of Performance (COP) in wintertime and Energy Efficiency Ratio (EER) in summertime between configurations with and without the coupling with HAGHE. In addition, two seasonal performance SCOP and SEER coefficients have been calculated considering, not only the inlet air temperatures into the Air-Cooled Heat Pump, but also their frequency of occurrence, the off-set external temperature (16 °C), the nominal external temperature and heating and cooling loads.


Energies ◽  
2021 ◽  
Vol 14 (12) ◽  
pp. 3563
Author(s):  
Evangelos Bellos ◽  
Christos Tzivanidis

The objective of the present study is the parametric investigation of a ground source heat pump for space heating purposes with boreholes. The working fluid in the heat pump is CO2, and the geothermal field includes boreholes with vertical heat exchangers (U-tube). This study is conducted with a developed model in Engineering Equation Solver which is validated with data from the literature. Ten different parameters are investigated and more specifically five parameters about the heat pump cycle and five parameters for the geothermal unit. The heat pump’s examined parameters are the high pressure, the heat exchanger effectiveness, the temperature level in the heater outlet, the flow rate of the geothermal fluid in the evaporator and the heat exchanger thermal transmittance in the evaporator. The other examined parameters about the geothermal unit are the ground mean temperature, the grout thermal conductivity, the inner diameter of the U-tube, the number of the boreholes and the length of every borehole. In the nominal design, it is found that the system’s coefficient of performance is 4.175, the heating production is 10 kW, the electricity consumption is 2.625 kW, and the heat input from the geothermal field is 10.23 kW. The overall resistance of the borehole per length is 0.08211 mK/W, while there are 4 boreholes with borehole length at 50 m. The parametric analysis shows the influence of the ten examined parameters on the system’s performance and on the geothermal system characteristics. This work can be used as a reference study for the design and the investigation of future geothermal-driven CO2 heat pumps.


A 21 kW ground source heat pump (GSHP) operating since 2013 in Alaska is described in this paper. Six years of successful operation in an extreme climate and measured performance data from 2013 to 2017 prove the viability of heat pumps for extreme cold regions. Summary of performance evaluation data such as monthly electric energy use and cost, savings of the heat pump system compared to the cost of heating oil, energy extracted from the ground, heat delivered to building are tabulated by months. The coefficient of performance (COP) of the heat pump is calculated from the experimental data, which show the COP to vary from a maximum value of 4.15 to a minimum value of 2.34 depending on the heating load of the month and the ground temperature. Cost comparison shows savings by heat pump over regular heating oil boilers of 80% efficiency. In cold regions it is of concern that GSHP can create frozen ground or permafrost around the ground heat exchanger coil by extracting too much heat from the ground. A finite element heat conduction simulation performed over the ground heat exchanger coil spanning over a 30-year period shows that small volumes of frozen ground form around the coil each season, but they melt away during the summer by the recharge of heat from the solar heat gain. The mechanical system of the heat pump, sensors for measurements and cost of the system components are presented, which would be valuable to designers implementing heat pumps in various locations of the world.


2016 ◽  
Vol 2 (2) ◽  
Author(s):  
Kusnandar Kusnandar ◽  
Kusnandar Kusnandar

Heat pump is a device that can be make heat and cool , which is functions as a cooling evaporator can be replaced to be a heating condenser. With adding a heat exchanger in the heat pump can provide better effect of heating and cooling. In this experiment, the heat pump using type hydrocarbon refrigerantand type friendly refrigerant to the environment, one of refrigerant isR-290. From the results that obtained value Coefficient Of Performance (COP) in the heat pump that uses a counter flow heat exchanger is 4.8 while the heat pump that does not use a counterflow heat exchanger obtained COP of 4.1. Efficiencies increase in the heat pump without using counter flow heat exchanger is 74%, otherwise the efficiency decrease of the heat pump using heat pump is 85%.