Materials Modeling - a key for the Design of Advanced High Temperature Reactor Components

2007 ◽  
pp. 50-57
Author(s):  
Maria Samaras ◽  
Wolfgang Hoffelner ◽  
Chu Chun Fu ◽  
Michel Guttmann ◽  
Roger E. Stoller
2021 ◽  
Vol 151 ◽  
pp. 107983
Author(s):  
Lianjie Wang ◽  
Wei Sun ◽  
Bangyang Xia ◽  
Yang Zou ◽  
Rui Yan

2010 ◽  
Vol 76 (764) ◽  
pp. 383-385 ◽  
Author(s):  
Taiju SHIBATA ◽  
Junya SUMITA ◽  
Taiyo MAKITA ◽  
Takashi TAKAGI ◽  
Eiji KUNIMOTO ◽  
...  

Author(s):  
Charles Forsberg

A combined-cycle power plant is proposed that uses heat from a high-temperature nuclear reactor and hydrogen produced by the high-temperature reactor to meet base-load and peak-load electrical demands. For base-load electricity production, air is compressed; flows through a heat exchanger, where it is heated to between 700 and 900°C; and exits through a high-temperature gas turbine to produce electricity. The heat, via an intermediate heat-transport loop, is provided by a high-temperature reactor. The hot exhaust from the Brayton-cycle turbine is then fed to a heat recovery steam generator that provides steam to a steam turbine for added electrical power production. To meet peak electricity demand, after nuclear heating of the compressed air, hydrogen is injected into the combustion chamber, combusts, and heats the air to 1300°C—the operating conditions for a standard natural-gas-fired combined-cycle plant. This process increases the plant efficiency and power output. Hydrogen is produced at night by electrolysis or other methods using energy from the nuclear reactor and is stored until needed. Therefore, the electricity output to the electric grid can vary from zero (i.e., when hydrogen is being produced) to the maximum peak power while the nuclear reactor operates at constant load. Because nuclear heat raises air temperatures above the auto-ignition temperatures of the hydrogen and powers the air compressor, the power output can be varied rapidly (compared with the capabilities of fossil-fired turbines) to meet spinning reserve requirements and stabilize the grid.


Author(s):  
Linsen Li ◽  
Haomin Yuan ◽  
Kan Wang

This paper introduces a first-principle steady-state coupling methodology using the Monte Carlo Code RMC and the CFD code CFX which can be used for the analysis of small and medium reactors. The RMC code is used for neutronics calculation while CFX is used for Thermal-Hydraulics (T-H) calculation. A Pebble Bed-Advanced High Temperature Reactor (PB-AHTR) core is modeled using this method. The porous media is used in the CFX model to simulate the pebble bed structure in PB-AHTR. This research concludes that the steady-state coupled calculation using RMC and CFX is feasible and can obtain stable results within a few iterations.


Sign in / Sign up

Export Citation Format

Share Document