Postoperative Plasma Mitochondrial DNA and Cytokine Profiles of Elderly Patients Undergoing Minimally Invasive Aortic Valve Replacement

Author(s):  
Maria Serrano-Teruel ◽  
Fernando Fernandez-Rodriguez ◽  
Alberto Bouzas-Mosquera ◽  
Mercedes Fernandez-Moreno ◽  
Paula Dieguez-Garcia ◽  
...  

Introduction Mitochondrial DNA (mtDNA) is gaining increasing interest as a marker of cellular damage and could also act as an inflammatory mediator in cardiopulmonary bypass induced postoperative inflammatory response. Although minimally invasive heart valve surgery reportedly reduces inflammation, the mtDNA and cytokine profile in this context remains unclear. Materials and Methods Here, we report a prospective series of 40 elderly patients with aortic stenosis who underwent bioprosthetic aortic valve replacement (AVR) through upper ministernotomy with either a sutureless (n = 20) or a conventional (n = 20) valve. Primary end points included serial plasma levels of mtDNA (T1: at baseline; T2: 4 hours after surgery; and T3: 24s hour after surgery), cytokines (interleukin-6 [IL-6], tumor necrosis factor-α [TNF-α]), and myocardial necrosis biomarkers (MNBs), whereas secondary end points included clinical and echocardiographic data. Results Significant increases in the postoperative plasma levels (T2) of mtDNA, cytokines, and MNBs were observed in all patients. The postoperative plasma levels of mtDNA, TNF-α, and MNBs showed no significant differences between the treatment groups, although there was a trend toward lower levels in the sutureless group. The decreases in aortic cross-clamp and cardiopulmonary bypass times seen in the sutureless group were associated with significant lower postoperative levels (T2 and T3) of IL-6. Conclusion AVR through upper ministernotomy was associated with a significant increase in postoperative plasma levels of mtDNA and cytokines. There was no difference in the mtDNA levels between the sutureless and conventional valve groups, suggesting a similar level of inflammation in both groups. However, the shorter operation time observed in the sutureless valve group was associated with significantly lower postoperative levels of IL-6, indicating potential clinical benefits.


Author(s):  
Sven Martens ◽  
Andreas Zierer ◽  
Anja Ploss ◽  
Sami Sirat ◽  
Aleksandra Miskovic ◽  
...  

Objective For elderly patients with symptomatic aortic valve stenosis, aortic valve replacement with tissue valves is still the treatment of choice. Stentless valves were introduced to clinical practice for better hemodynamic features as compared with stented tissue valves. However, the implantation is more complex and time demanding, especially in minimal invasive aortic valve replacement. We present our clinical data on 22 patients having received a sutureless ATS 3f Enable aortic bioprosthesis via partial upper sternotomy. Methods The procedure was performed using CPB with cardioplegic arrest. After resection of the stenotic aortic valve and debridement of the annulus, the valve was inserted and released. Mean age was 79 years, and mean logistic Euroscore was 13. Subvalvular myectomy was performed in two patients. Prosthetic valve sizes were 19 mm (n = 1), 21 mm (n = 7), 23 mm (n = 6), 25 mm (n = 6), and 27 mm (n = 2). Results Implantation of the valve required 10 ± 6 minutes. Cardiopulmonary bypass and aortic crossclamp time were 87 ± 16 and 55 ± 11 minutes, respectively. Early mortality (<90 days) was 9% (2 patients). No paravalvular leakage was detected intraoperatively or in follow-up echocardiography. The mean transvalvular gradients were 9 ± 6 mm Hg at discharge and 8 ± 2 mm Hg at 1-year follow-up. Conclusions Sutureless valve implantation via partial sternotomy is feasible and safe with the ATS 3f Enable bioprosthesis. Reduction of cardiopulmonary bypass and aortic crossclamp time seems possible with increasing experience. Hemodynamic data are very promising with low gradients at discharge and after 12 month. Sutureless valve implantation via minimal invasive access may be an alternative treatment option for elderly patients with high comorbidity.



Author(s):  
Daniel M. Bethencourt ◽  
Jennifer Le ◽  
Gabriela Rodriguez ◽  
Robert W. Kalayjian ◽  
Gregory S. Thomas

Objective This study reports the evolution of a minimally invasive aortic valve replacement (mini-AVR) technique that uses a right anterior minithoracotomy approach with central cannulation, for a 13-year period. This technique has become our standard approach for isolated primary AVR in nearly all patients. Methods This observational study evaluated perioperative clinical outcomes of patients 18 years or older who underwent mini-AVR from November 2003 to June 2015. Results The mini-AVR technique was used in 202 patients during two periods of 2003 to 2009 (n = 65, “early”) and 2010 to 2015 (n = 137, “late”). The mean ± SD age was 72.5 ± 12.9 years and 60% were male. Demographic parameters were statistically similar between the study periods, except for increased body weight in the later period (75.3 ± 14.7 vs 80.9 ± 20.8 kg, P = 0.03). The mean cardiopulmonary bypass and aortic cross-clamp times were significantly different by each year and Bonferroni adjustment, with significant decreases in cardiopulmonary bypass and aortic cross-clamp times beginning 2006. Compared with the early study period, late study period patients were more often extubated intraoperatively (52% vs 12%, P < 0.001), had less frequent prolonged ventilator use postoperatively (6% vs 16%, P = 0.018), required fewer blood transfusions (mean, 2.0 ± 2.3 U vs 3.6 ± 3.0 U; P = 0.011), and had shorter postoperative stay (6.3 ± 4.5 days vs 8.0 ± 5.9 days, P = 0.026). Numerically, fewer postoperative strokes (1% vs 6%, P = 0.09) and fewer reoperations for bleeding (3% vs 6%, P = 0.3) occurred in the late period. In-hospital mortality did not differ (1/65 early vs 3/137 late). Conclusions Overall mini-AVR intraoperative and postoperative clinical outcomes improved for this 13-year experience.



2014 ◽  
Vol 62 (06) ◽  
pp. 482-488 ◽  
Author(s):  
Matthias Trampisch ◽  
Markus Schlömicher ◽  
Nina Pillokeit ◽  
Attik Rehman ◽  
Nathalie Garstka ◽  
...  


Perfusion ◽  
2008 ◽  
Vol 23 (5) ◽  
pp. 275-278 ◽  
Author(s):  
I Dimarakis ◽  
D Stefanou ◽  
G Yarham ◽  
J Mulholland ◽  
J Anderson

Minimally invasive aortic valve replacement has been established in many centres over the last decade. Although numerous modifications have been described to date, these solely involve variations of the utilized operative incision. Total miniaturized cardiopulmonary bypass (tMCPB) offers the theoretical potential of reducing even further the overall procedural “invasiveness”. We describe our initial experience of an application of MCPB for aortic valve replacement through a minimal incision.



Author(s):  
Davida A. Robinson ◽  
Carl A. Johnson ◽  
Ariana M. Goodman ◽  
Peter A. Knight

Objective Aortic root enlargement may be necessary to implant adequately sized valves to avoid patient–prosthetic mismatch. Our objective was to assess the feasibility of annular enlargement during aortic valve replacement via a right anterior minithoracotomy. Methods Twelve consecutive patients undergoing elective minimally invasive aortic valve replacement requiring annular enlargement over a 2-year period were retrospectively reviewed. A right anterior minithoracotomy was performed in all patients. Cardiopulmonary bypass and aortic crossclamp times, hospital length of stay, postoperative complications, rate of reoperation, echocardiographic data, and mortality were analyzed. Results Mean age was 66 years ± 14. Mean body mass index was 34 ± 7.8 kg/m2. All patients had normal preoperative ejection fractions. Indications for aortic valve replacement were severe (3/12, 25%) or critical (9/12, 75%) aortic stenosis due to degenerative aortic valve disease (10/12, 83%) and congenitally bicuspid aortic valve (2/12, 17%). Cardiopulmonary bypass and aortic crossclamp times were 144.7 ± 14.7 minutes and 111.7 ± 10.6 minutes, respectively. The median postoperative length of stay was 4 days. Peak and mean aortic valve gradients on postreplacement intraoperative transesophageal echocardiography were 14.5 ± 9.4 mmHg and 7.2 ± 4.2 mmHg, respectively, with no perivalvular leak on intraoperative or follow-up transthoracic echocardiogram. Postoperative transthoracic echocardiography had peak and mean aortic valve gradients of 12.1 ± 6.9 mmHg and 6.3 ± 3.7 mmHg, respectively. There were no postoperative mortalities. Freedom from reoperation was 100%. Conclusions Annular enlargement performed during minimally invasive aortic valve replacement is feasible. Basic minimally invasive skills are recommended prior to instituting these more advanced techniques.



Author(s):  
Mark J. Cunningham ◽  
Christopher E. Berberian ◽  
Vaughn A. Starnes

Objective Transthoracic minimally invasive aortic valve replacement (TMI-AVR) is gaining popularity despite criticism that time from incision to the initiation of cardiopulmonary bypass (exposure time, ET), cardiopulmonary bypass time (CPBT), and cross-clamp time (XCT) is excessive. Database analysis was used to characterize these parameters and their associated learning curves. Methods From 2004 to 2008, 101 patients underwent TMI-AVR at a single institution. Of them, 54 were men (53%) and 47 were women (47%). Mean age was 70 years (range, 24–90 years). ET includes 6-cm incision, second intercostals anterior thoracotomy, medial transection of the third rib, opening pericardial sac, retracing pericardium with stay sutures, placing aortic arterial, and right arterial venous bypass cannulae. ET, CPBT, XCT, and operating room times were calculated. Logarithmic trend analysis established associated learning curves. Results ET steadily improved over time. ET decreased from an average of 51 minutes for the first 25 patients to 39 minutes for the most recent 25 patients. When surgeon experience reached 10 procedures, the ET trend line began to decline steadily and plateaued by 55 cases. Cross-clamp (55 ± 21 minutes), cardiopulmonary bypass (77 ± 31 minutes), and operating room times (304 ± 67 minutes) all remained constant. There were no early deaths or conversions to sternotomy. Conclusions ET learning curve for TMI-AVR was reflected after 10 procedures with continued gradual improvement. Reliability of TMI-AVR was observed in the absence of a learning curve for XCT, CPBT, and operating room times. A sternal-sparing transthoracic approach for AVR can be performed safely, with expected operative times equivalent to sternotomy.



2020 ◽  
Vol 31 (1) ◽  
pp. 56-62
Author(s):  
Aschraf El-Essawi ◽  
Marco Follis ◽  
René Brouwer ◽  
Ingo Breitenbach ◽  
Steffen Groeger ◽  
...  

Abstract OBJECTIVES Minimally invasive extracorporeal circuits have been introduced to cardiac surgery in an attempt to reduce the negative effects of cardiopulmonary bypass on patient outcome. On the other hand, transcatheter aortic valve replacement (TAVR) provides an excellent option to replace the aortic valve without the need for cardiopulmonary bypass. Several studies have compared TAVR to surgical aortic valve replacement (SAVR) but none have utilized a minimally invasive extracorporeal circuit. METHODS We retrospectively analysed the results of both procedures among octogenarians operated in our department from 2003 to 2016. Excluded were patients with an active endocarditis, a history of previous cardiac surgery, as well as those who had a minimally invasive surgical approach. This yielded 81 and 142 octogenarians in the SAVR and TAVR groups, respectively. To compensate for a lack of randomization, we performed a propensity score analysis, which yielded 68 patient pairs for the final analysis. RESULTS The 30-day postoperative mortality was lower in the SAVR group (1.5% vs 5.9%) but not statistically significant (P  = 0.4). In contrast, the incidence of postoperative atrial fibrillation was lower in the TAVR group (13% vs 29%) but also non-significant (P  = 0.2). Finally, the incidence of paravalvular leakage was in favour of the SAVR group (2.9% vs 52%; P  = 0.001) while the transfusion requirement was significantly lower in the TAVR group (29% vs 72%; P &lt; 0.001). CONCLUSIONS SAVR utilizing a minimally invasive extracorporeal circuit improves the quality of patient care and can offer an alternative to TAVR in octogenarians.



2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
S Van Genechten ◽  
J Claessens ◽  
A Kaya ◽  
A Yilmaz

Abstract Background Cardiac surgery is still looking for new minimally invasive techniques with less trauma and better cosmetic results. In the field of aortic valve replacement, several types of less invasive procedures were introduced, allowing a reduction in blood loss, infections, ventilation times, morbidity and mortality. The most common technique for minimally invasive aortic valve replacement is the mini-sternotomy approach. In this report, the initial experience with a non-sternotomy approach for aortic valve replacement by means of a totally endoscopic surgical technique is presented. Methods The totally endoscopic aortic valve replacement was carried out in 201 patients (59,7% males, mean age: 71.6±11.7 years) from October 2017 until October 2019. Severe aortic valve stenosis was the surgical indication for all patients, who had a mean EuroSCORE II of 2.35±3.82. The surgery was carried out with the patient in supine position and a standard zero-degree optics was used. A 20 mm working port in the 2nd right intercostal space and two 5 mm trocars gained access to the aorta. After groin cannulation, cardiopulmonary bypass was initiated. Transthoracic aortic cross-clamping followed by antegrade administration of a single shot cold mixed-blood cardioplegia was assessed. The aortotomy was followed by the excision of the stenotic aortic valve and the aortic valve prosthesis was implanted in supra-annular position. After the closure of the aorta, an external pacemaker wire was placed. Results Mean cross-clamp and cardiopulmonary bypass times were 62±14 and 94±25 minutes, respectively. No conversion to a sternotomy was needed. The mean length of stay at the intensive care unit was 69.4±149.6 hours while patients spend 9.6±10 days at the hospital. Due to our new fast track protocol, the mean hospital stay in the last two months was 6.1 days (26 patients, 12.9%). The average postoperative blood loss (24h) was 251±298 mL and the patients were ventilated for 6.9±9 hours. In 10 patients (4.9%), re-exploration in an endoscopic way was needed. None of them had a surgical bleeding focus. No paravalvular leakages were detected at discharge. 69 patients (34.7%) developed atrial fibrillation after surgery. In addition, 10 patients (4.9%) underwent a pacemaker implantation postoperatively whereas 4 patients (1.9%) suffered from a CVA. Finally, the 30-day mortality was 2.0%. Conclusion These results concerning the feasibility and safety of totally endoscopic aortic valve replacement are promising. The aortic cross clamping times are acceptable, and the morbidity and mortality rates are low. Long term results are needed to confirm these initial findings. Funding Acknowledgement Type of funding source: Private hospital(s). Main funding source(s): Jessa Hospital





Sign in / Sign up

Export Citation Format

Share Document