Failure Investigation of Water Distribution Systems in a Large City in China Based on the Pipe Failure Database

Author(s):  
Zhaoyang Song ◽  
Wei Liu
Water ◽  
2019 ◽  
Vol 11 (3) ◽  
pp. 553 ◽  
Author(s):  
Young Choi ◽  
Joong Kim

This study proposes a multi-objective optimal design approach for water distribution systems, considering mechanical system redundancy under multiple pipe failure. Mechanical redundancy is applied to the system’s hydraulic ability, based on the pressure deficit between the pressure requirements under abnormal conditions. The developed design approach shows the relationships between multiple pipe failure states and system redundancy, for different numbers of pipe-failure conditions (e.g., first, second, third, …, tenth). Furthermore, to consider extreme demand modeling, the threshold of the demand quantity is investigated simultaneously with multiple pipe failure modeling. The design performance is evaluated using the mechanical redundancy deficit under extreme demand conditions. To verify the proposed design approach, an expanded version of the well-known benchmark network is used, configured as an ideal grid-shape, and the multi-objective harmony search algorithm is used as the optimal design approach, considering construction cost and system mechanical redundancy. This optimal design technique could be used to propose a standard for pipe failure, based on factors such as the number of broken pipes, during failure condition analysis for redundancy-based designs of water distribution systems.


2018 ◽  
Vol 193 ◽  
pp. 02002
Author(s):  
Thi Minh Lanh Pham ◽  
Hai Ha Pham ◽  
Nguyen Anh Thu Do ◽  
Dinh Hong Le

All pipes in water supply network are installed underground, so it is difficult to identify pipe failure location during the operation of a system. Prediction of the risk of pipe failure in the water distribution systems is necessary for preparation of reparations and displacement of a pipe network system. Based on the probability of pipe failure, it will be possible to save money and labor cost for water supply companies. Many studies have been conducted on this topic, some of which used experimental models, others used statistical models in which recently many authors used regression model, but almost all the models come up with calculating the pipe failure rate per unit length of pipe in a year. It is not a direct probability of pipe failure. This article reviews various methods to evaluate pipe failure in water distribution systems. Based on that, the authors proposed two models: Regression Logistic Model and Decision Tree Model that would support an effective decision making for detecting the pipe failure and proposing appropriate solutions.


2017 ◽  
Vol 186 ◽  
pp. 117-126 ◽  
Author(s):  
Raziyeh Farmani ◽  
Konstantinos Kakoudakis ◽  
Kourosh Behzadian ◽  
David Butler

Author(s):  
Jun Liu ◽  
Yinyin Kang

Abstract The consideration of isolation valves and segments is essential for evaluating the water service and resilience of water distribution systems when shutdowns are required under pipe failure. However, little work has been done on assessing the resilience response and intervention based on segments. This study investigates the impact of intervention (valve density and protection of critical segment) and response (recovery time and recovery sequence) on system resilience taking valve layout into consideration. An algorithm to identify segments based on the graph theory is proposed. Resilience is quantified using the satisfactory rate of the water supply demand. Critical segments are ranked based on resilience analysis. The resilience evaluation method is applied to a case study network. It is found that valve optimization can significantly reduce the number of valves without considerably decreasing the resilience performance. Valve density and the protection of critical segment can reduce the severity of pipe failure, while efficient recovery response can reduce the severity and shorten the duration of pipe failure simultaneously. The criticality of segments depends on the segment location and hydraulic interdependency among segments.


2014 ◽  
Vol 70 (11) ◽  
pp. 1764-1773 ◽  
Author(s):  
K. Diao ◽  
R. Farmani ◽  
G. Fu ◽  
M. Astaraie-Imani ◽  
S. Ward ◽  
...  

Large water distribution systems (WDSs) are networks with both topological and behavioural complexity. Thereby, it is usually difficult to identify the key features of the properties of the system, and subsequently all the critical components within the system for a given purpose of design or control. One way is, however, to more explicitly visualize the network structure and interactions between components by dividing a WDS into a number of clusters (subsystems). Accordingly, this paper introduces a clustering strategy that decomposes WDSs into clusters with stronger internal connections than external connections. The detected cluster layout is very similar to the community structure of the served urban area. As WDSs may expand along with urban development in a community-by-community manner, the correspondingly formed distribution clusters may reveal some crucial configurations of WDSs. For verification, the method is applied to identify all the critical links during firefighting for the vulnerability analysis of a real-world WDS. Moreover, both the most critical pipes and clusters are addressed, given the consequences of pipe failure. Compared with the enumeration method, the method used in this study identifies the same group of the most critical components, and provides similar criticality prioritizations of them in a more computationally efficient time.