Scaling Effects in Direct Shear Tests

Author(s):  
Andrés D. Orlando ◽  
Daniel M. Hanes ◽  
Hayley H. Shen ◽  
Masami Nakagawa ◽  
Stefan Luding
2021 ◽  
Vol 13 (15) ◽  
pp. 8201
Author(s):  
Lihua Li ◽  
Han Yan ◽  
Henglin Xiao ◽  
Wentao Li ◽  
Zhangshuai Geng

It is well known that geomembranes frequently and easily fail at the seams, which has been a ubiquitous problem in various applications. To avoid the failure of geomembrane at the seams, photocuring was carried out with 1~5% photoinitiator and 2% carbon black powder. This geomembrane can be sprayed and cured on the soil surface. The obtained geomembrane was then used as a barrier, separator, or reinforcement. In this study, the direct shear tests were carried out with the aim to investigate the interfacial characteristics of photocured geomembrane–clay/sand. The results show that a 2% photoinitiator has a significant effect on the impermeable layer for the photocured geomembrane–clay interface. As for the photocured geomembrane–sand interface, it is reasonable to choose a geomembrane made from a 4% photoinitiator at the boundary of the drainage layer and the impermeable layer in the landfill. In the cover system, it is reasonable to choose a 5% photoinitiator geomembrane. Moreover, as for the interface between the photocurable geomembrane and clay/sand, the friction coefficient increases initially and decreases afterward with the increase of normal stress. Furthermore, the friction angle of the interface between photocurable geomembrane and sand is larger than that of the photocurable geomembrane–clay interface. In other words, the interface between photocurable geomembrane and sand has better shear and tensile crack resistance.


2017 ◽  
Vol 45 (6) ◽  
pp. 674-687 ◽  
Author(s):  
Gary John Fowmes ◽  
Neil Dixon ◽  
Liwei Fu ◽  
Catalin Alexandru Zaharescu

1999 ◽  
Vol 14 ◽  
pp. 185-194
Author(s):  
Po-Kai Wu ◽  
Jin-Ying Qiu ◽  
T. Uchimura ◽  
F. Tatsuoka

2021 ◽  
Vol 20 (2) ◽  
pp. 332-345
Author(s):  
Gökhan Altay ◽  
◽  
Cafer Kayadelen ◽  
Taha Taskiran ◽  
Baki Bagriacik ◽  
...  

The parameters concerning the interaction between geocell and granular materials is required for the design of many geotechnical structures. With this in mind, a series of experiments using simple direct shear tests are conducted in order to understand the frictional properties between geocells filled with granular materials. The 54 test samples are prepared by filling the geocell with granular materials having three different gradations. These samples are tested at three different relative densities under three different normal stress levels. As a result, it was observed that interface resistance between the geocells filled with granular material is found to be generally greater than in the samples without geocells. Additionally, these samples with geocells are found to be stiffer; this is due to the fact that the samples with geocell gained more cohesion because geocells confined the grains within a restricted volume.


Sign in / Sign up

Export Citation Format

Share Document