Study of the Stability of 3C-SiC Single Crystals Using High-Resolution Diffuse X-Ray Scattering

2010 ◽  
Author(s):  
D. Dompoint ◽  
A. Boulle ◽  
I. G. Galben-Sandulache ◽  
D. Chaussende ◽  
Gabriel Ferro ◽  
...  
2013 ◽  
Vol 46 (4) ◽  
pp. 939-944 ◽  
Author(s):  
Marcelo Goncalves Hönnicke ◽  
Xianrong Huang ◽  
Cesar Cusatis ◽  
Chaminda Nalaka Koditwuakku ◽  
Yong Q. Cai

Spherical analyzers are well known instruments for inelastic X-ray scattering (IXS) experiments. High-resolution IXS experiments almost always use Si single crystals as monochromators and spherical analyzers. At higher energies (>20 keV) Si shows a high energy resolution (<10 meV), at an exact symmetric back-diffraction condition, since the energy resolution is given by the real part of the susceptibility or polarizability. However, at low energies (<10 keV), high energy resolution is difficult to achieve with Si. α-SiO2 (quartz) can be an option, since it offers high energy resolution at low energies. In this work, the characterization of high-quality α-SiO2 is presented. Such characterization is made by high-resolution rocking curve, topography and lattice parameter mapping in different samples from a single block. X-ray optics with α-SiO2 for IXS at lower energies (from 2.5 to 12.6 keV) with medium to high energy resolution (from 90 to 11 meV) are proposed and theoretically exploited.


Author(s):  
Ilya V. Roslyakov ◽  
Andrei P. Chumakov ◽  
Andrei A. Eliseev ◽  
Alexey P. Leontiev ◽  
Oleg V. Konovalov ◽  
...  

2021 ◽  
Vol 54 (3) ◽  
Author(s):  
Peter Nadazdy ◽  
Jakub Hagara ◽  
Petr Mikulik ◽  
Zdenko Zaprazny ◽  
Dusan Korytar ◽  
...  

A four-bounce monochromator assembly composed of Ge(111) and Ge(220) monolithic channel-cut monochromators with V-shaped channels in a quasi-dispersive configuration is presented. The assembly provides an optimal design in terms of the highest transmittance and photon flux density per detector pixel while maintaining high beam collimation. A monochromator assembly optimized for the highest recorded intensity per detector pixel of a linear detector placed 2.5 m behind the assembly was realized and tested by high-resolution X-ray diffraction and small-angle X-ray scattering measurements using a microfocus X-ray source. Conventional symmetric and asymmetric Ge(220) Bartels monochromators were similarly tested and the results were compared. The new assembly provides a transmittance that is an order of magnitude higher and 2.5 times higher than those provided by the symmetric and asymmetric Bartels monochromators, respectively, while the output beam divergence is twice that of the asymmetric Bartels monochromator. These results demonstrate the advantage of the proposed monochromator assembly in cases where the resolution can be partially sacrificed in favour of higher transmittance while still maintaining high beam collimation. Weakly scattering samples such as nanostructures are an example. A general advantage of the new monochromator is a significant reduction in the exposure time required to collect usable experimental data. A comparison of the theoretical and experimental results also reveals the current limitations of the technology of polishing hard-to-reach surfaces in X-ray crystal optics.


Sign in / Sign up

Export Citation Format

Share Document