Peak velocity of elbow joint during hair combing activity for normal subject

2018 ◽  
Author(s):  
Hasyatun Che-Nan ◽  
Azmin Sham Rambely
2021 ◽  
Vol 11 (20) ◽  
pp. 9403
Author(s):  
Koike Yuji ◽  
Okino Akihisa ◽  
Takeda Kazuhisa ◽  
Takanami Yasuhiro ◽  
Toyohiro Hamaguchi

In this study, the motion therapy elements necessary for student education were clarified through comparison of the therapeutic motion techniques of therapists and students using an educational arm robot (Samothrace: SAMO). Eight therapists and 25 fourth-year students participated. The therapeutic motion therapy task was a reciprocating exercise in which the elbow joint of SAMO was flexed from an extended position and then re-extended. This was performed for three types of muscle tone intensities (mild, moderate, and severe), and the peak velocity, angle ratio, velocity time, and movement time were recorded using SAMO. These data were then compared using analysis of covariance. It was found that the SAMO elbow joint kinematic data generated by therapists differed significantly from those of students for different muscle tones. Multiple comparisons showed that the therapeutic motion techniques of students were associated with a higher peak velocity, smaller peak angle ratio, and shorter peak velocity time and movement time than those of the therapists. Thus, when students learn therapeutic motion techniques, they should be taught to (1) deal with multiple muscle tone intensities and (2) reduce the joint movement speed applied to the patient to extend the exercise time and ensure maximum joint movement range.


2021 ◽  
Author(s):  
KOIKE Yuji ◽  
OKINO Akihisa ◽  
TAKEDA Kazuhisa ◽  
TAKANAMI Yasuhiro ◽  
Toyohiro Hamaguchi

Abstract Background: The purpose of this study was to clarify the motion therapy elements necessary for the education of students through comparison of the therapeutic motion techniques of therapists and students using an educational arm robot (Samothrace: SAMO) set with varying degrees of muscle tone pathology.Methods: The participants included eight therapists with more than five years of clinical experience and 25 fourth-year students from occupational therapy training schools who had completed their clinical practice. The therapeutic motion therapy task was a reciprocating exercise in which the elbow joint of SAMO was flexed from an extended position and then re-extended. This was performed three times for each of the three types of muscle tone intensities (mild, moderate, and severe), for a total of nine repetitions. The peak velocity, peak angle ratio, peak velocity time, and movement time were recorded using SAMO while the subjects performed the therapeutic motion therapy task. These data were compared using analysis of covariance. Results: The SAMO elbow joint kinematic data generated by therapists were significantly different than those of students for different muscle tones. It was clear from multiple comparisons that the therapeutic motion techniques of students were associated with higher peak velocity, smaller peak angle ratio, and shorter peak velocity time and movement time than those of therapists. Conclusion: The therapeutic motion techniques applied by the students in response to the muscle tone condition of the arm robot were different from those applied by therapists, suggesting that the students were not able to perform the therapeutic motion techniques in response to the degree of the muscle tone intensity in the same way that an expert could. Based on the results, when students learn therapeutic motion techniques, they should be taught to 1) deal with multiple muscle tone intensities and 2) reduce the speed of joint movement applied to the patient, extend the exercise time, and ensure maximum range of joint movement. These were the suggested guiding factors.


Author(s):  
M.D. Coutts ◽  
E.R. Levin ◽  
J.G. Woodward

While record grooves have been studied by transmission electron microscopy with replica techniques, and by optical microscopy, the former are cumbersome and restricted and the latter limited by lack of depth of focus and resolution at higher magnification. With its great depth of focus and ease in specimen manipulation, the scanning electron microscope is admirably suited for record wear studies.A special RCA sweep frequency test record was used with both lateral and vertical modulation bands. The signal is a repetitive, constant-velocity sweep from 2 to 20 kHz having a duration and repetitive rate of approximately 0.1 sec. and a peak velocity of 5.5 cm/s.A series of different pickups and numbers of plays were used on vinyl records. One centimeter discs were then cut out, mounted and coated with 200 Å of gold to prevent charging during examination. Wear studies were made by taking micrographs of record grooves having 1, 10 and 50 plays with each stylus and comparing with typical “no-play” grooves. Fig. 1 shows unplayed grooves in a vinyl pressing with sweep-frequency modulation in the lateral mode.


2011 ◽  
Vol 9 (2) ◽  
pp. 90 ◽  
Author(s):  
Rohola Hemmati ◽  
Mojgan Gharipour ◽  
Hasan Shemirani ◽  
Alireza Khosravi ◽  
Elham Khosravi ◽  
...  

Background:Appearance of microalbuminuria, particularly in patients with hypertension, might be associated with a higher prevalence of left ventricular (LV) dysfunction and geometric abnormalities. This study was undertaken to determine whether high urine albumin to creatinine ratio (UACR) as a sensitive marker for microalbuminuria can be associated with LV hypertrophy (LVH) and systolic and diastolic LV dysfunction.Methods:The study population consisted of 125 consecutive patients with essential uncomplicated hypertension. Urine albumin and creatinine concentration was determined by standard methods. LVH was defined as a LV mass index >100 g/m2 of body surface area in women and >130 g/m2 in men. Echocardiographic LV systolic and diastolic parameters were measured.Results:The prevalence of microalbuminuria in patients with essential hypertension was 5.6 %. UACR was significantly no different in patients with LVH than in patients with normal LV geometry (21.26 ± 31.55 versus 17.80 ± 24.52 mg/mmol). No significant correlation was found between UACR measurement and systolic and diastolic function parameters, including early to late diastolic peak velocity (E/A) ratio (R=-0.192, p=0.038), early diastolic peak velocity to early mitral annulus velocity (E/E') ratio (R=-0.025, p=0.794), LV ejection fraction (R=0.008, p=0.929), and LV mass (R=-0.132, p=0.154). According to the receiver operator characteristic (ROC) curve analysis, UACR measurement was not an acceptable indicator of LVH with areas under the ROC curves 0.514 (95 % confidence interval 0.394–0.634). The optimal cut-off value for UACR for predicting LVH was identified at 9.4, yielding a sensitivity of 51.6 % and a specificity of 48.3 %.Conclusion:In patients with uncomplicated essential hypertension, abnormal systolic and diastolic LV function and geometry cannot be effectively predicted by the appearance of microalbuminuria.


2019 ◽  
Vol 40 (Supplement_1) ◽  
Author(s):  
A Bielecka-Dabrowa ◽  
P Gasiorek ◽  
A Sakowicz ◽  
M Banach

Abstract Purpose The study aimed to identify echocardiographic, hemodynamic and biochemical predictors of unfavourable prognosis after ischemic strokes of undetermined etiology (ESUS) in patients (pts) at age <65. Methods Out of 520 ischemic stroke pts we selected 64 pts diagnosed with ESUS [mean age 54 (SD: 47–58) years, 42% males] and additional 36 without stroke but with similar risk profile, which were treated as a reference group [age 53 (SD: 47–58) years, 61% males]. All pts underwent echocardiography, non-invasive assessment of hemodynamic parameters using SphygmoCor tonometer (Atcor Med., Australia), HDL subfraction distribution using Lipoprint (Quantimetrix) as well as measurements of selected biomarkers. Follow-up was 12 months. Results At 12-month follow-up 9% of patients had died, and recurrent ischemic stroke also occurred in 9% of patients - only in the ESUS group (Figure). Patients who died had significantly lower levels of LDL and HDL cholesterol (included HDL-8 and -9 subfractions) and higher level of triglicerides (p=0.01, p=0.01, and p=0.02; respectively), lower level of adiponectin (p=0.01), lower value of mean early diastolic (E') mitral annular velocity (p=0.04) and lower diastolic blood pressure (p=0.04). The atrial fibrillation (AF) occurred in 10% of pts during the 12 months (log-rang, p=0.254) (Figure). The log-rank test showed that ESUS group had a significantly poorer outcome of AF in the first 2 months after hospitalization compared to reference group (11% vs 5%, p=0.041). Based on a Kaplan-Meier analysis, the outcome of re-hospitalizationin the 1st year was 28% (18/64) in the ESUS group and 17% (6/36); log-rank, p=0.058. In the multivariate analysis mean early diastolic (E') mitral annular velocity (odds ratio [OR] 0.75, 95% confidence interval [CI]: 0.6–0.94; p=0.01) was significantly associated with CV hospitalizations assessed at 12-month follow-up. The only independent predictor of AF occurrence in the 12-month follow-up was lower value of Tissue Doppler-derived right ventricular systolic excursion velocity S' (OR 0.65, 95% Cl 0.45–0.93; p=0.01). The only independent predictor of recurrent stroke was the ratio of peak velocity of early diastolic transmitral flow to peak velocity of early diastolic mitral annular motion as determined by pulsed wave Doppler (E/E') (OR 0.75, 95% CI: 0.6–0.94; p=0.01). E/E' ratio was also independently associated with composite endpoint consisting of death, hospitalization and recurrent stroke (OR 1.90, 95% CI 1.1–3.2, p=0.01). Kaplan-Meier Analysis - survival and AF Conclusions The indices of diastolic dysfunction are significantly associated with unfavourable prognosis after ESUS. There is a robust role for outpatient cardiac monitoring especially during first 2 months after ESUS to detect potential AF. Acknowledgement/Funding The study was financed by research grants no. 502-03/5-139-02/502-54-229-18 of the Medical University of Lodz


1995 ◽  
Vol 75 (3) ◽  
pp. 372
Author(s):  
H P Frizelle ◽  
P J Zetlaoui

Sign in / Sign up

Export Citation Format

Share Document