scholarly journals Optimizing magnetoresistive sensor signal-to-noise via pinning field tuning

2019 ◽  
Vol 115 (12) ◽  
pp. 122406 ◽  
Author(s):  
J. Moulin ◽  
A. Doll ◽  
E. Paul ◽  
M. Pannetier-Lecoeur ◽  
C. Fermon ◽  
...  
2013 ◽  
Vol 281 ◽  
pp. 71-74
Author(s):  
Na Chen ◽  
Shao Pu Yang ◽  
Cun Zhi Pan

In a fault detection system A/D conversion is a necessary step, in which quantization issues are unavoidable. Problems about quantization effects can be solved properly by using the dither technique. Firstly quantization problems of A/D conversion in a fault diagnosis system are discussed. Then the principle of dithering technique is introduced from the view of probability statistics. In further more, it is tested that fault signals whose amplitude is less than the quantization interval can be extracted, and that coherent harmonic interference in quantizing process can also be eliminated. Finally the result shows that by using dither technique the system can gain an enhanced level of fault detection with a faint signal-to-noise ratio loss, which has a direct guidance on engineering design in sensor-signal-sampling system.


Author(s):  
Robert M. Glaeser

It is well known that a large flux of electrons must pass through a specimen in order to obtain a high resolution image while a smaller particle flux is satisfactory for a low resolution image. The minimum particle flux that is required depends upon the contrast in the image and the signal-to-noise (S/N) ratio at which the data are considered acceptable. For a given S/N associated with statistical fluxtuations, the relationship between contrast and “counting statistics” is s131_eqn1, where C = contrast; r2 is the area of a picture element corresponding to the resolution, r; N is the number of electrons incident per unit area of the specimen; f is the fraction of electrons that contribute to formation of the image, relative to the total number of electrons incident upon the object.


Author(s):  
David A. Grano ◽  
Kenneth H. Downing

The retrieval of high-resolution information from images of biological crystals depends, in part, on the use of the correct photographic emulsion. We have been investigating the information transfer properties of twelve emulsions with a view toward 1) characterizing the emulsions by a few, measurable quantities, and 2) identifying the “best” emulsion of those we have studied for use in any given experimental situation. Because our interests lie in the examination of crystalline specimens, we've chosen to evaluate an emulsion's signal-to-noise ratio (SNR) as a function of spatial frequency and use this as our critereon for determining the best emulsion.The signal-to-noise ratio in frequency space depends on several factors. First, the signal depends on the speed of the emulsion and its modulation transfer function (MTF). By procedures outlined in, MTF's have been found for all the emulsions tested and can be fit by an analytic expression 1/(1+(S/S0)2). Figure 1 shows the experimental data and fitted curve for an emulsion with a better than average MTF. A single parameter, the spatial frequency at which the transfer falls to 50% (S0), characterizes this curve.


Author(s):  
W. Kunath ◽  
K. Weiss ◽  
E. Zeitler

Bright-field images taken with axial illumination show spurious high contrast patterns which obscure details smaller than 15 ° Hollow-cone illumination (HCI), however, reduces this disturbing granulation by statistical superposition and thus improves the signal-to-noise ratio. In this presentation we report on experiments aimed at selecting the proper amount of tilt and defocus for improvement of the signal-to-noise ratio by means of direct observation of the electron images on a TV monitor.Hollow-cone illumination is implemented in our microscope (single field condenser objective, Cs = .5 mm) by an electronic system which rotates the tilted beam about the optic axis. At low rates of revolution (one turn per second or so) a circular motion of the usual granulation in the image of a carbon support film can be observed on the TV monitor. The size of the granular structures and the radius of their orbits depend on both the conical tilt and defocus.


Author(s):  
David L. Wetzel ◽  
John A. Reffner ◽  
Gwyn P. Williams

Synchrotron radiation is 100 to 1000 times brighter than a thermal source such as a globar. It is not accompanied with thermal noise and it is highly directional and nondivergent. For these reasons, it is well suited for ultra-spatially resolved FT-IR microspectroscopy. In efforts to attain good spatial resolution in FT-IR microspectroscopy with a thermal source, a considerable fraction of the infrared beam focused onto the specimen is lost when projected remote apertures are used to achieve a small spot size. This is the case because of divergence in the beam from that source. Also the brightness is limited and it is necessary to compromise on the signal-to-noise or to expect a long acquisition time from coadding many scans. A synchrotron powered FT-IR Microspectrometer does not suffer from this effect. Since most of the unaperatured beam’s energy makes it through even a 12 × 12 μm aperture, that is a starting place for aperture dimension reduction.


Author(s):  
M. Unser ◽  
B.L. Trus ◽  
A.C. Steven

Since the resolution-limiting factor in electron microscopy of biological macromolecules is not instrumental, but is rather the preservation of structure, operational definitions of resolution have to be based on the mutual consistency of a set of like images. The traditional measure of resolution for crystalline specimens in terms of the extent of periodic reflections in their diffraction patterns is such a criterion. With the advent of correlation averaging techniques for lattice rectification and the analysis of non-crystalline specimens, a more general - and desirably, closely compatible - resolution criterion is needed. Two measures of resolution for correlation-averaged images have been described, namely the differential phase residual (DPR) and the Fourier ring correlation (FRC). However, the values that they give for resolution often differ substantially. Furthermore, neither method relates in a straightforward way to the long-standing resolution criterion for crystalline specimens.


Sign in / Sign up

Export Citation Format

Share Document