Nonattended Home Automated Continuous Positive Airway Pressure Titration: Comparison with Polysomnography

2003 ◽  
Vol 128 (3) ◽  
pp. 353-357 ◽  
Author(s):  
B. Tucker Woodson ◽  
Adrian Saurejan ◽  
Laura T. Brusky ◽  
Joseph K. Han

OBJECTIVE: Automatic adjusting nasal continuous positive airway pressure titration (APAP) has been introduced as an alternative method of establishing pressures for patients with sleep apnea. The performance and accuracy of APAP in nonattended home environment are controversial. This study assessed APAP polysomnographic outcomes and accuracy in a nonattended home environment. STUDY DESIGN AND SETTING: We conducted a retrospective consecutive case series of 24 consecutive patients who had nonattended APAP and simultaneous full polysomnography (PSG). RESULTS: APAP was tolerated and reduced obstructive Apnea-Hypopnea Index (AHI) to < 10 events/h in all patients. Mean AHI decreased from 38.4 (21.2) to 5.9 (6.6) events/h. Central apneas worsened in one patient. A therapeutic pressure was determined in 91% of patients. Autoset accurately measured residual AHI compared with PSG ( R = 0.77, P < 0.001). APAP overestimated the AHI by 1.4 events/h. CONCLUSIONS: Nonattended APAP is successful in many patients in determining a therapeutic positive pressure setting. Reported AHI via Autoset is similar to that of PSG. SIGNIFICANCE: APAP reduces AHI and is tolerated in a nonattended environment.

2022 ◽  
Vol 11 (2) ◽  
pp. 307
Author(s):  
Tzu-Pei Wang ◽  
Hsin-Hsien Li ◽  
Hui-Ling Lin

Accumulated secretion above the endotracheal tube cuff can be aspirated during extubation after deflation. The possible techniques for minimizing pulmonary aspiration from subglottic secretion during extubation have not been well explored. This study aimed to determine the effect of different extubation techniques on secretion leakage. An endotracheal tube was placed in a tube mimicking an airway. We measured the leak volume of water or artificial sputum of different viscosities with three extubation techniques—negative pressure with suctioning; positive pressure with a resuscitator; and continuous positive airway pressure set at 5, 10, and 20 cm H2O. Extubation with continuous positive airway pressure resulted in lower secretion leakage than that with negative pressure with suctioning and positive pressure with a resuscitator. Increasing the continuous positive airway pressure level decreased secretion leakage volume during extubation. We further determined a correlation of leak volume with sputum viscosity. Continuous positive airway pressure at 5 cm H2O produced lower volume secretion leakage than the other two techniques, even with higher secretion viscosity. Based on these results, using continuous positive airway pressure with a previous ventilator continuous positive airway pressure/positive end-expiratory pressure setting for extubation is recommended.


Author(s):  
Bayane Sabsabi ◽  
Ava Harrison ◽  
Laura Banfield ◽  
Amit Mukerji

Objective The study aimed to systematically review and analyze the impact of nasal intermittent positive pressure ventilation (NIPPV) versus continuous positive airway pressure (CPAP) on apnea of prematurity (AOP) in preterm neonates. Study Design In this systematic review and meta-analysis, experimental studies enrolling preterm infants comparing NIPPV (synchronized, nonsynchronized, and bi-level) and CPAP (all types) were searched in multiple databases and screened for the assessment of AOP. Primary outcome was AOP frequency per hour (as defined by authors of included studies). Results Out of 4,980 articles identified, 18 studies were included with eight studies contributing to the primary outcome. All studies had a high risk of bias, with significant heterogeneity in definition and measurement of AOP. There was no difference in AOPs per hour between NIPPV versus CPAP (weighted mean difference = −0.19; 95% confidence interval [CI]: −0.76 to 0.37; eight studies, 456 patients). However, in a post hoc analysis evaluating the presence of any AOP (over varying time periods), the pooled odds ratio (OR) was lower with NIPPV (OR: 0.46; 95% CI: 0.32–0.67; 10 studies, 872 patients). Conclusion NIPPV was not associated with decrease in AOP frequency, although demonstrated lower odds of developing any AOP. However, definite recommendations cannot be made based on the quality of the published evidence. Key Points


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Narongkorn Saiphoklang ◽  
Kanyada Leelasittikul ◽  
Apiwat Pugongchai

AbstractContinuous positive airway pressure (CPAP) is simple and effective treatment for obstructive sleep apnea (OSA) patients. However, the CPAP prediction equation in each country is different. This study aimed to predict CPAP in Thai patients with OSA. A retrospective study was conducted in Thai patients, who OSA was confirmed by polysomnography and CPAP titration from January 2015 to December 2018. Demographics, body mass index (BMI), neck circumference (NC), Epworth sleepiness scale, apnea–hypopnea index (AHI), respiratory disturbance index (RDI), mean and lowest pulse oxygen saturation (SpO2), and optimal pressure were recorded. A total of 180 subjects were included: 72.8% men, age 48.7 ± 12.7 years, BMI 31.0 ± 6.3 kg/m2, NC 40.7 ± 4.1 cm, AHI 42.5 ± 33.0 per hour, RDI 47.1 ± 32.8 per hour, and lowest SpO2 77.1 ± 11.0%. Multiple linear regression analysis identified NC, BMI, RDI, and lowest SpO2. A final CPAP predictive equation was: optimal CPAP (cmH2O) = 4.614 + (0.173 × NC) + (0.067 × BMI) + (0.030 × RDI) − (0.076 × lowest SpO2). This model accounted for 50.0% of the variance in the optimal pressure (R2 = 0.50). In conclusion, a CPAP prediction equation can be used to explain a moderate proportion of the titrated CPAP in Thai patients with OSA. However, the CPAP predictive equation in each country may be different due to differences of ethnicity and physiology.Trial registration: TCTR20200108003.


2018 ◽  
Vol 37 (1) ◽  
pp. 24-32
Author(s):  
Jennifer M. Guay ◽  
Dru Carvi ◽  
Deborah A. Raines ◽  
Wendy A. Luce

Respiratory distress continues to be a major cause of neonatal morbidity. Current neonatal practice recommends the use of nasal continuous positive airway pressure (nCPAP) in the immediate resuscitation and continued support of neonates of all gestations with clinical manifestations of respiratory distress. Despite the many short- and long-term benefits of nCPAP, many neonatal care units have met resistance in its routine use. Although there have been numerous recent publications investigating the use and outcomes of various modes of nCPAP delivery, surfactant administration, mechanical ventilation, and other forms of noninvasive respiratory support (high-flow nasal cannula, nasal intermittent positive pressure ventilation), there has been a relative lack of publications addressing the practical bedside care of infants managed on nCPAP. Effective use of nCPAP requires a coordinated interprofessional team approach, ongoing assessment of the neonate, troubleshooting the nCPAP circuit, and parent education.


2021 ◽  
pp. 135245852110103
Author(s):  
Sulaiman Khadadah ◽  
R John Kimoff ◽  
Pierre Duquette ◽  
Vincent Jobin ◽  
Yves Lapierre ◽  
...  

Objective: The aim of this study was to evaluate the effect of continuous positive airway pressure (CPAP) treatment on the Fatigue Severity Scale (FSS, preplanned primary outcome), another fatigue measure, sleep quality, somnolence, pain, disability, and quality of life in multiple sclerosis (MS) patients with obstructive sleep apnea-hypopnea (OSAH). Methods: In a randomized, double-blind trial (NCT01746342), MS patients with fatigue, poor subjective sleep quality, and OSAH (apnea-hypopnea index of ⩾ 15 events per hour/sleep), but without severe OSAH (apnea-hypopnea index > 30, and 4% oxygen desaturation index > 15 events/hour or severe somnolence), were randomized to fixed CPAP or sham CPAP for 6 months. Outcome assessments were performed at 3 and 6 months. Results: Of 49 randomized patients, 34 completed the protocol. Among completers, FSS did not improve with CPAP compared to sham at 6 months. FSS tended to improve ( p = 0.09), and sleepiness (Epworth Sleepiness Scale) improved significantly ( p = 0.03) at 3 months with CPAP compared to sham, but there were no other improvements with CPAP at either study evaluation. Conclusion: In non-severe OSAH patients, CPAP did not significantly improve the primary outcome of FSS change at 6 months. In secondary analyses, we found a trend to improved FSS, and a significant reduction in somnolence with CPAP at 3 months.