Estimating live fine fuels moisture content using meteorologically-based indices

2001 ◽  
Vol 10 (2) ◽  
pp. 223 ◽  
Author(s):  
D. X. Viegas ◽  
J. Piñol ◽  
M. T. Viegas ◽  
R. Ogaya

Field measurements of moisture content of several fine fuels (shrub vegetation and live foliage) were performed in Central Portugal and in Catalunya (NE Spain) for 1–10 years. Seasonal and interannual variation of live fine fuels of several species in two regions of the Iberian Peninsula are analysed. The species were grouped in three sets according to their relatively high, intermediate or low seasonal variability. Meteorological data from nearby stations were collected in each study area and used in the evaluation of some indicators of fuel moisture that are used in the Canadian Forest Fire Danger Rating System, namely the Drought Code (DC). It was found that in the summer season the slow response of live fine fuel moisture content (LFFMC) to meteorological conditions, namely to precipitation, was well described by the DC. Empirical correlations between LFFMC and DC for each species and site are proposed.

1992 ◽  
Vol 2 (2) ◽  
pp. 69 ◽  
Author(s):  
DX Viegas ◽  
MTSP Viegas ◽  
AD Ferreira

Moisture content of ten fine fuels frequent in the forests of CentralPortugal and in other Mediterranean areas was measured daily since 1986. Average monthly results are presented for the period of 1987-1990. Pinuspinaster sticks were used as a predictor of dead fuel moisture content. A reasonable correlation was obtained with the moisture content of Pinus pinaster dead needles and Eucalyptus globulus dead leaves. Two options of the MOISTURE module of BEHAVE system were also tested to predict the daily minimum value of fine dead fuel moisture content. Predicted values were always lower than direct measurements, specially when only meteorological data was used. A better agreement was obtained when known moisture content of the previous day was introduced. Using statistical data of oily fire occurrence in some districts around the site where the tests were made, for the same period of time, the probability of fire occurrence, the average number of daily fires and the average area burned each year was analysed as a function of dead pine needles moisture content. Three distinct zones, around and adjacent to the test site showed a very similar behaviour.


2021 ◽  
Vol 13 (21) ◽  
pp. 4224
Author(s):  
Eleni Dragozi ◽  
Theodore M. Giannaros ◽  
Vasiliki Kotroni ◽  
Konstantinos Lagouvardos ◽  
Ioannis Koletsis

The frequent occurrence of large and high-intensity wildfires in the Mediterranean region poses a major threat to people and the environment. In this context, the estimation of dead fine fuel moisture content (DFMC) has become an integrated part of wildfire management since it provides valuable information for the flammability status of the vegetation. This study investigates the effectiveness of a physically based fuel moisture model in estimating DFMC during severe fire events in Greece. Our analysis considers two approaches, the satellite-based (MODIS DFMC model) and the weather station-based (AWSs DFMC model) approach, using a fuel moisture model which is based on the relationship between the fuel moisture of the fine fuels and the water vapor pressure deficit (D). During the analysis we used weather station data and MODIS satellite data from fourteen wildfires in Greece. Due to the lack of field measurements, the models’ performance was assessed only in the case of the satellite data by using weather observations obtained from the network of automated weather stations operated by the National Observatory of Athens (NOA). Results show that, in general, the satellite-based model achieved satisfactory accuracy in estimating the spatial distribution of the DFMC during the examined fire events. More specifically, the validation of the satellite-derived DFMC against the weather-station based DFMC indicated that, in all cases examined, the MODIS DFMC model tended to underestimate DFMC, with MBE ranging from −0.3% to −7.3%. Moreover, in all of the cases examined, apart from one (Sartis’ fire case, MAE: 8.2%), the MAE of the MODIS DFMC model was less than 2.2%. The remaining numerical results align with the existing literature, except for the MAE case of 8.2%. The good performance of the satellite based DFMC model indicates that the estimation of DFMC is feasible at various spatial scales in Greece. Presently, the main drawback of this approach is the occurrence of data gaps in the MODIS satellite imagery. The examination and comparison of the two approaches, regarding their operational use, indicates that the weather station-based approach meets the requirements for operational DFMC mapping to a higher degree compared to the satellite-based approach.


2020 ◽  
Vol 29 (6) ◽  
pp. 560
Author(s):  
Jane G. Cawson ◽  
Petter Nyman ◽  
Christian Schunk ◽  
Gary J. Sheridan ◽  
Thomas J. Duff ◽  
...  

Field measurements of surface dead fine fuel moisture content (FFMC) are integral to wildfire management, but conventional measurement techniques are limited. Automated fuel sticks offer a potential solution, providing a standardised, continuous and real-time measure of fuel moisture. As such, they are used as an analogue for surface dead fine fuel but their performance in this context has not been widely evaluated. We assessed the ability of automated fuel sticks to predict surface dead FFMC across a range of forest types. We combined concurrent moisture measurements of the fuel stick and surface dead fine fuel from 27 sites (570 samples), representing nine broad forest fuel categories. We found a moderate linear relationship between surface dead FFMC and fuel stick moisture for all data combined (R2=0.54), with fuel stick moisture averaging 3-fold lower than surface dead FFMC. Relationships were typically stronger for individual forest fuel categories (median R2=0.70; range=0.55–0.87), suggesting the sticks require fuel-specific calibration for use as an analogue of surface dead fine fuel. Future research could identify fuel properties that will enable more generalised calibration functions.


2020 ◽  
Vol 29 (6) ◽  
pp. 548
Author(s):  
Jane G. Cawson ◽  
Petter Nyman ◽  
Christian Schunk ◽  
Gary J. Sheridan ◽  
Thomas J. Duff ◽  
...  

Field measurements of surface dead fine fuel moisture content (FFMC) are integral to wildfire management, but conventional measurement techniques are limited. Automated fuel sticks offer a potential solution, providing a standardised, continuous and real-time measure of fuel moisture. As such, they are used as an analogue for surface dead fine fuel but their performance in this context has not been widely evaluated. We assessed the ability of automated fuel sticks to predict surface dead FFMC across a range of forest types. We combined concurrent moisture measurements of the fuel stick and surface dead fine fuel from 27 sites (570 samples), representing nine broad forest fuel categories. We found a moderate linear relationship between surface dead FFMC and fuel stick moisture for all data combined (R2=0.54), with fuel stick moisture averaging 3-fold lower than surface dead FFMC. Relationships were typically stronger for individual forest fuel categories (median R2=0.70; range=0.55–0.87), suggesting the sticks require fuel-specific calibration for use as an analogue of surface dead fine fuel. Future research could identify fuel properties that will enable more generalised calibration functions.


2009 ◽  
Vol 18 (1) ◽  
pp. 71 ◽  
Author(s):  
Ana Daría Ruiz González ◽  
Jose Antonio Vega Hidalgo ◽  
Juan Gabriel Álvarez González

A statistical methodology is presented for developing moisture content models from repeated measurements made on non-destructive repeated measurements. Empirical vapour exchange models for dead fine fuels generated in Pinus radiata and P. pinaster stands are developed by using the methodology proposed. Experiments were carried out with five types of fuel particles (surface and aerial fine fuels) of the two species of pine, in Lugo (Galicia, north-west Spain). The samples of each fuel type were collected and placed inside an instrument shelter so that vapour exchange with the atmosphere was the only source of moisture in the fuels. Statistical criteria obtained from the residuals indicated that the fitted models were acceptable. The cross-validation results also confirmed the validity of the fitted models. The model underlined the decisive role played by the time lag in dead fine fuel moisture content variation.


2008 ◽  
Vol 112 (9) ◽  
pp. 3618-3627 ◽  
Author(s):  
Mariano García ◽  
Emilio Chuvieco ◽  
Héctor Nieto ◽  
Inmaculado Aguado

2004 ◽  
Vol 92 (3) ◽  
pp. 322-331 ◽  
Author(s):  
Emilio Chuvieco ◽  
David Cocero ◽  
David Riaño ◽  
Pilar Martin ◽  
Javier Martı́nez-Vega ◽  
...  

Author(s):  
Chunquan Fan ◽  
Binbin He ◽  
Peng Kong ◽  
Hao Xu ◽  
Qiang Zhang ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document