Chemical Imaging with a Solid-State near Infrared Spectrometer Based on a Digital Micro-Mirror Array Device Coupled with Hadamard Transform Spectroscopy

2012 ◽  
Vol 45 (9) ◽  
pp. 1070-1078 ◽  
Author(s):  
Dong Xiang ◽  
Mark A. Arnold
Micromachines ◽  
2019 ◽  
Vol 10 (2) ◽  
pp. 149 ◽  
Author(s):  
Zifeng Lu ◽  
Jinghang Zhang ◽  
Hua Liu ◽  
Jialin Xu ◽  
Jinhuan Li

In the Hadamard transform (HT) near-infrared (NIR) spectrometer, there are defects that can create a nonuniform distribution of spectral energy, significantly influencing the absorbance of the whole spectrum, generating stray light, and making the signal-to-noise ratio (SNR) of the spectrum inconsistent. To address this issue and improve the performance of the digital micromirror device (DMD) Hadamard transform near-infrared spectrometer, a split waveband scan mode is proposed to mitigate the impact of the stray light, and a new Hadamard mask of variable-width stripes is put forward to improve the SNR of the spectrometer. The results of the simulations and experiments indicate that by the new scan mode and Hadamard mask, the influence of stray light is restrained and reduced. In addition, the SNR of the spectrometer also is increased.


2015 ◽  
Vol 35 (5) ◽  
pp. 0530003
Author(s):  
王晓朵 Wang Xiaoduo ◽  
刘华 Liu Hua ◽  
党博石 Dang Boshi ◽  
全向前 Quan Xiangqian ◽  
许家林 Xu Jialin ◽  
...  

2008 ◽  
Author(s):  
Wei Wei ◽  
Shanglian Huang ◽  
Yong Zhu ◽  
Ning Wang ◽  
Jie Zhang ◽  
...  

2011 ◽  
Vol 483 ◽  
pp. 417-421
Author(s):  
Yuan Jun Guo ◽  
Zhi Yu Wen ◽  
Zhi Hai Zhang ◽  
Wei Wang

A programmable micro mirror has been used in a near infrared spectrometer in order to achieve the purpose of signal multiplexing, to solve the problem of low luminous flux when using single slit and to increase the signal-to-noise (SNR) ratio. Use Hadamard Transform (HT) and programmable micro mirror as its encoding mask to detect the whole spectrum with a single detector, research and analyze the enhancement of SNR of the weak signal. First of all, the mask symbol number is fixed as 63-order based on the Hadamard Transform principle, calculate the optimal S-Matrix, and then the encoding mask has been realized by micro mirror. At last, carry out some experimental verifications as well as data analyzing, discuss the alternating spectrum signal which produce an effect on transformational algorithm, bring out the coadded upswing plan. The result shows that: the conflict of resolution and SNR can be well settled with Hadamard multiplex. The SNR can be increased by the factor of 3.5, which is identical with the theoretic result.


2016 ◽  
Vol 380 ◽  
pp. 161-167 ◽  
Author(s):  
Xiaoduo Wang ◽  
Hua Liu ◽  
Larissa Juschkin ◽  
Yunpeng Li ◽  
Jialin Xu ◽  
...  

NIR news ◽  
2019 ◽  
Vol 30 (5-6) ◽  
pp. 35-38
Author(s):  
Verena Wiedemair ◽  
Christian Wolfgang Huck

The use of ever smaller near-infrared instruments is becoming more and more prevalent, since they are cheaper, more versatile and often advertised as high-performance spectrometer. The last claim is rarely verified by independent researchers, which is why the presented work evaluates the performance of three hand-held spectrometers in comparison to a benchtop instrument. Seventy-seven samples comprising buckwheat, millet and oat were investigated for their total antioxidant capacity using Folin–Ciocalteu and near-infrared spectroscopy. Partial least squares regression models were established using cross- and test set validation. Results showed that all instruments were able to predict total antioxidant capacity to some extent. The coefficients of determinations ranged from 0.823 to 0.951 for cross-validated and from 0.849 to 0.952 for test set validated models. Errors for cross-validated models ranged from 1.11 to 2.08 mgGAE/g and for test set validated models from 1.02 to 1.86 mgGAE/g.


2021 ◽  
Author(s):  
Russell Farrugia ◽  
Barnaby Portelli ◽  
Ivan Grech ◽  
Joseph Micallef ◽  
Owen Casha ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document