Ultrastructural calibration model for proficiency testing

Author(s):  
Reiko Aoki ◽  
Dorival Leão ◽  
Juan P. Mamani Bustamante ◽  
Filidor Vilca
1997 ◽  
Vol 78 (02) ◽  
pp. 855-858 ◽  
Author(s):  
Armando Tripodi ◽  
Veena Chantarangkul ◽  
Marigrazia Clerici ◽  
Barbara Negri ◽  
Pier Mannuccio Mannucci

SummaryA key issue for the reliable use of new devices for the laboratory control of oral anticoagulant therapy with the INR is their conformity to the calibration model. In the past, their adequacy has mostly been assessed empirically without reference to the calibration model and the use of International Reference Preparations (IRP) for thromboplastin. In this study we reviewed the requirements to be fulfilled and applied them to the calibration of a new near-patient testing device (TAS, Cardiovascular Diagnostics) which uses thromboplastin-containing test cards for determination of the INR. On each of 10 working days citrat- ed whole blood and plasma samples were obtained from 2 healthy subjects and 6 patients on oral anticoagulants. PT testing on whole blood and plasma was done with the TAS and parallel testing for plasma by the manual technique with the IRP CRM 149S. Conformity to the calibration model was judged satisfactory if the following requirements were met: (i) there was a linear relationship between paired log-PTs (TAS vs CRM 149S); (ii) the regression line drawn through patients data points, passed through those of normals; (iii) the precision of the calibration expressed as the CV of the slope was <3%. A good linear relationship was observed for calibration plots for plasma and whole blood (r = 0.98). Regression lines drawn through patients data points, passed through those of normals. The CVs of the slope were in both cases 2.2% and the ISIs were 0.965 and 1.000 for whole blood and plasma. In conclusion, our study shows that near-patient testing devices can be considered reliable tools to measure INR in patients on oral anticoagulants and provides guidelines for their evaluation.


The Synergist ◽  
2008 ◽  
Vol 19 (7) ◽  
pp. 42
Author(s):  
James A. Kenny
Keyword(s):  

Author(s):  
Maria Enescu ◽  
Marian Enescu

Customer experience maturity of any organization is important for its business results. This paper describes two kinds of maturity models, one based on competency evaluation of the employees on customer’s best applied practices, and the second on maturity of using digital tools to increase the customer good experience when working with the company. These approaches are useful when discuss the performance of enterprises providing products or services in the age of customer. The included case studies show the applicability of the procedures and open a way to be extended for proficiency testing workshops (for similar business) or in ranking the enterprises from the viewpoint of customer experience maturity.


Author(s):  
Klimenko Lina Yu ◽  
Shkarlat Galyna L ◽  
Shovkova Zoia V ◽  
Yaremenko Vitaliy D ◽  
Shpychak Oleg S

Metronidazole is the most popular representative of antiprotozoal medicines from the group of 5-nitroimidazoles. Metronidazole blocks the enzymes of alcohol dehydrogenase and acetaldehyde dehydrogenase, therefore when its joint taking with alcohol it is observed the strong intoxication syndrome and fatal poisonings too. Therefore metronidazole can be a potential object of chemical toxicological investigations. The purpose of our paper is to develop HPLC/UV-procedure of metronidazole quantification with application of the system of HPLC-analyzer MiLiChrome® A-0230 implemented in practice of forensic medical laboratories in Russia and Ukraine and carry out step-by-step validation of the developed procedure. Chromatographic conditions: Eluent A (0.2 M LiClO4 – 0.005 M HClO4) and Eluent B (acetonitrile) wereused as the mobile phase components; HPLC microcolumn Ø2×75 mm and ProntoSIL 120-5-C18 AQ, 5 μm were used as an analytical column; temperature was 40°С; flow rate was 100 μl/min; gradient elution mode was from 5% to 100% Eluent B for 40 min, then 100% Eluent B for 3 min; detection was performed at 277 nm. Retention time for metronidazole is 5.95 min. Since metronidazole is easy soluble and stable enough in the solutions of diluted alkalis 0.001 M sodium hydroxide solution has been proposed for preparation of the solutions in developing HPLC/UV-procedure of metronidazole quantification. Validation of the procedure has been carried out in the variants of the method of calibration curve and method of standard by such parameters as in process stability, linearity/calibration model, accuracy and precision within 3 different analytical runs using different batches of reagents and different glassware; experiments have been performed by three different analysts. New procedure of metronidazole quantitative determination by the method of HPLC/UV has been developed. Its validation has been carried out and acceptability for application has been shown.


2020 ◽  
Vol 16 ◽  
Author(s):  
Aykut Kul ◽  
Murat Ozdemir ◽  
Selma Ozilhan ◽  
Olcay Sagirli

Background: Buprenorphine is quite common in the illicit market. Buprenorphine-containing drugs abuse is frequently encountered in patients. The analysis methods used to determine the abuse of buprenorphine and norbuprenorphine are important for forensic science. Buprenorphine is metabolized to norbuprenorphine by the liver. Objective: Therefore, the determination of buprenorphine and norbuprenorphine in urine is one of the methods to determine the abuse of buprenorphine. Methods: In this study, we have developed a precise, simple, and rapid ultra-performance liquid chromatographytandem mass spectrometer method for the determination of buprenorphine and norbuprenorphine simultaneously. Results: The developed method was validated in terms of selectivity and linearity, which was in the range of 9–1800 ng/mL for both buprenorphine and norbuprenorphine. The intra-assay and inter-assay accuracy and precision were found within acceptable limits of the EMA guideline. Lower limits of quantitation were 9 ng/mL for both buprenorphine and norbuprenorphine. Conclusion: The developed method was successfully applied for the determination of both analytes in the proficiency testing samples.


Sign in / Sign up

Export Citation Format

Share Document