The use of dummy atoms in X-ray macromolecular crystallography

2004 ◽  
Vol 10 (4) ◽  
pp. 319-343 ◽  
Author(s):  
A. Urzhumtsev ◽  
V.Y. Lunin
Crystals ◽  
2018 ◽  
Vol 8 (7) ◽  
pp. 273 ◽  
Author(s):  
José Brandão-Neto ◽  
Leonardo Bernasconi

Macromolecular crystallography at cryogenic temperatures has so far provided the majority of the experimental evidence that underpins the determination of the atomic structures of proteins and other biomolecular assemblies by means of single crystal X-ray diffraction experiments. One of the core limitations of the current methods is that crystal samples degrade as they are subject to X-rays, and two broad groups of effects are observed: global and specific damage. While the currently successful approach is to operate outside the range where global damage is observed, specific damage is not well understood and may lead to poor interpretation of the chemistry and biology of the system under study. In this work, we present a phenomenological model in which specific damage is understood as the result of a single process, the steady excitation of crystal electrons caused by X-ray absorption, which acts as a trigger for the bulk effects that manifest themselves in the form of global damage and obscure the interpretation of chemical information from XFEL and synchrotron structural research.


2009 ◽  
Vol 16 (2) ◽  
pp. 143-151 ◽  
Author(s):  
Robin L. Owen ◽  
James M. Holton ◽  
Clemens Schulze-Briese ◽  
Elspeth F. Garman

Accurate measurement of photon flux from an X-ray source, a parameter required to calculate the dose absorbed by the sample, is not yet routinely available at macromolecular crystallography beamlines. The development of a model for determining the photon flux incident on pin diodes is described here, and has been tested on the macromolecular crystallography beamlines at both the Swiss Light Source, Villigen, Switzerland, and the Advanced Light Source, Berkeley, USA, at energies between 4 and 18 keV. These experiments have shown that a simple model based on energy deposition in silicon is sufficient for determining the flux incident on high-quality silicon pin diodes. The derivation and validation of this model is presented, and a web-based tool for the use of the macromolecular crystallography and wider synchrotron community is introduced.


Author(s):  
José Brandão-Neto ◽  
Leonardo Bernasconi

Macromolecular crystallography at cryogenic temperatures has so far provided the majority of the experimental evidence that underpins the determination of the atomic structures of proteins and other biomolecular assemblies by means of single crystal X-ray diffraction experiments. One of the core limitations of the current methods is that crystal samples degrade as they are subject to X-rays, and two broad groups of effects are observed: global and specific damage. While the currently successful approach is to operate outside the range where global damage is observed, specific damage is not well understood and may lead to poor interpretation of the chemistry and biology of the system under study. In this work, we present a phenomenological model in which specific damage is understood as the result of a single process, the steady excitation of crystal electrons caused by X-ray absorption, which acts as a trigger for the bulk effects that manifest themselves in the form of global damage and obscure the interpretation of chemical information from XFEL and synchrotron structural research.


2021 ◽  
Author(s):  
Dom Bellini

In X-ray macromolecular crystallography, cryoprotection of crystals mounted on harvesting loops is achieved when the water in the sample solvent transitions to vitreous ice before crystalline ice forms. This is achieved by rapid cooling in liquid nitrogen or propane. Protocols for protein crystal cryoprotection are based on either increasing environmental pressure or reducing the water fraction in the solvent. This study presents a new protocol for cryoprotecting crystals. It is based on vapour diffusion dehydration of the crystal drop to reduce the water fraction in the solvent by adding a highly concentrated salt solution, 13 M potassium formate (KF13), directly to the reservoir. Cryoprotection by the KF13 protocol is non-invasive to the crystal, high throughput, not labour intensive, can benefit diffraction resolution and ligand binding, and is very useful in cases with high redundancy such as drug discovery projects which utilize very large compound or fragment libraries. Moreover, an application of KF13 to discover new crystal hits from clear drops of equilibrated crystallization screening plates is also shown.


2014 ◽  
Vol 70 (a1) ◽  
pp. C1733-C1733
Author(s):  
Martin Fuchs ◽  
Robert Sweet ◽  
Lonny Berman ◽  
Dileep Bhogadi ◽  
Wayne Hendrickson ◽  
...  

We present the final design of the x-ray optical systems and experimental stations of the two macromolecular crystallography (MX) beamlines, FMX and AMX, at the National Synchrotron Light Source-II (NSLS-II). Along with its companion x-ray scattering beamline, LIX, this suite of Advanced Beamlines for Biological Investigations with X-rays (ABBIX, [1]) will begin user operation in 2016. The pair of MX beamlines with complementary and overlapping capabilities is located at canted undulators (IVU21) in sector 17-ID. The Frontier Microfocusing Macromolecular Crystallography beamline (FMX) will deliver a photon flux of ~5x10^12 ph/s at a wavelength of 1 Å into a spot of 1 - 50 µm size. It will cover a broad energy range from 5 - 30 keV, corresponding to wavelengths from 0.4 - 2.5 Å. The highly Automated Macromolecular Crystallography beamline (AMX) will be optimized for high throughput applications, with beam sizes from 4 - 100 µm, an energy range of 5 - 18 keV (0.7 - 2.5 Å), and a flux at 1 Å of ~10^13 ph/s. Central components of the in-house-developed experimental stations are a 100 nm sphere of confusion goniometer with a horizontal axis, piezo-slits to provide dynamic beam size changes during diffraction experiments, a dedicated secondary goniometer for crystallization plates, and sample- and plate-changing robots. FMX and AMX will support a broad range of biomedical structure determination methods from serial crystallography on micron-sized crystals, to structure determination of complexes in large unit cells, to rapid sample screening and data collection of crystals in trays, for instance to characterize membrane protein crystals and to conduct ligand-binding studies. Together with the solution scattering program at LIX, the new beamlines will offer unique opportunities for advanced diffraction experiments with micro- and mini-beams, with next generation hybrid pixel array detectors and emerging crystal delivery methods such as acoustic droplet ejection. This work is supported by the US National Institutes of Health.


1998 ◽  
Vol 54 (6) ◽  
pp. 1109-1118 ◽  
Author(s):  
Eleanor Dodson

The importance of validation techniques in X-ray structure determination and their relation to refinement procedures are discussed, with particular reference to atomic resolution structures. The requirements of deposition and publication, and the role of validation tools in this are analysed. The need for a rigorously defined file format is emphasized.


2012 ◽  
pp. 838-882
Author(s):  
Igor N. Serdyuk ◽  
Nathan R. Zaccai ◽  
Joseph Zaccai

2016 ◽  
Vol 72 (4) ◽  
pp. 454-466 ◽  
Author(s):  
Ulrich Zander ◽  
Guillaume Hoffmann ◽  
Irina Cornaciu ◽  
Jean-Pierre Marquette ◽  
Gergely Papp ◽  
...  

Currently, macromolecular crystallography projects often require the use of highly automated facilities for crystallization and X-ray data collection. However, crystal harvesting and processing largely depend on manual operations. Here, a series of new methods are presented based on the use of a low X-ray-background film as a crystallization support and a photoablation laser that enable the automation of major operations required for the preparation of crystals for X-ray diffraction experiments. In this approach, the controlled removal of the mother liquor before crystal mounting simplifies the cryocooling process, in many cases eliminating the use of cryoprotectant agents, while crystal-soaking experiments are performed through diffusion, precluding the need for repeated sample-recovery and transfer operations. Moreover, the high-precision laser enables new mounting strategies that are not accessible through other methods. This approach bridges an important gap in automation and can contribute to expanding the capabilities of modern macromolecular crystallography facilities.


2014 ◽  
Vol 70 (a1) ◽  
pp. C1737-C1737
Author(s):  
Pawel Grochulski ◽  
Miroslaw Cygler ◽  
Michel Fodje ◽  
Shaunivan Labiuk ◽  
James Gorin ◽  
...  

The Canadian Macromolecular Crystallography Facility (CMCF) at the Canadian Light Source (CLS) is a suite of fully automated beamlines, 08ID-1 and 08B1-1 [1]. It serves over 60 Canadian groups plus academic and commercial users in the US. Besides remote data collection, we offer Mail-In service where data are collected by CMCF staff. Beamline 08B1-1 has been in operation since 2011 and beamline 08ID-1 since 2006. When beamline 08ID-1 was designed, over 10 years ago, small crystals were defined as having sizes of 50-100 μm. Today, the most challenging experiments require more intense X-ray beams that can be focused to accommodate much smaller crystal sizes of less than 5 μm with flux on the order of 10^11 photons/s. To reach these stringent parameters, a new more powerful source of X-rays will be required, which will be provided by a longer small-gap in-vacuum undulator (SGU). To accommodate the higher power levels and to focus X-rays to a smaller focal spot with a high degree of spatial and temporal stability, the existing X-ray optical elements need to be upgraded. The remaining components of the project include a 5-axis alignment table for improving alignment of small samples with the microbeam, a high-efficiency robotic sample-changer and a single-photon X-ray detector. Several options for the new design will be discussed. These developments are consistent with the current direction of structural biology research at the CLS [2]. Since 2006 over 225 (240) papers and 400 (444) PDB deposits reported data collected at beamline 08ID-1. Parentheses indicate the total number for the CMCF. Many of these have been published in very high impact journals such as N. Engl. J. Med., Nature, Cell, Science, PNAS, among others (http://cmcf.lightsource.ca/publications/).


2019 ◽  
Vol 20 (6) ◽  
pp. 1401 ◽  
Author(s):  
Marius Schmidt

The focus of structural biology is shifting from the determination of static structures to the investigation of dynamical aspects of macromolecular function. With time-resolved macromolecular crystallography (TRX), intermediates that form and decay during the macromolecular reaction can be investigated, as well as their reaction dynamics. Time-resolved crystallographic methods were initially developed at synchrotrons. However, about a decade ago, extremely brilliant, femtosecond-pulsed X-ray sources, the free electron lasers for hard X-rays, became available to a wider community. TRX is now possible with femtosecond temporal resolution. This review provides an overview of methodological aspects of TRX, and at the same time, aims to outline the frontiers of this method at modern pulsed X-ray sources.