scholarly journals The Role of Validation in Macromolecular Crystallography

1998 ◽  
Vol 54 (6) ◽  
pp. 1109-1118 ◽  
Author(s):  
Eleanor Dodson

The importance of validation techniques in X-ray structure determination and their relation to refinement procedures are discussed, with particular reference to atomic resolution structures. The requirements of deposition and publication, and the role of validation tools in this are analysed. The need for a rigorously defined file format is emphasized.

2014 ◽  
Vol 70 (a1) ◽  
pp. C1733-C1733
Author(s):  
Martin Fuchs ◽  
Robert Sweet ◽  
Lonny Berman ◽  
Dileep Bhogadi ◽  
Wayne Hendrickson ◽  
...  

We present the final design of the x-ray optical systems and experimental stations of the two macromolecular crystallography (MX) beamlines, FMX and AMX, at the National Synchrotron Light Source-II (NSLS-II). Along with its companion x-ray scattering beamline, LIX, this suite of Advanced Beamlines for Biological Investigations with X-rays (ABBIX, [1]) will begin user operation in 2016. The pair of MX beamlines with complementary and overlapping capabilities is located at canted undulators (IVU21) in sector 17-ID. The Frontier Microfocusing Macromolecular Crystallography beamline (FMX) will deliver a photon flux of ~5x10^12 ph/s at a wavelength of 1 Å into a spot of 1 - 50 µm size. It will cover a broad energy range from 5 - 30 keV, corresponding to wavelengths from 0.4 - 2.5 Å. The highly Automated Macromolecular Crystallography beamline (AMX) will be optimized for high throughput applications, with beam sizes from 4 - 100 µm, an energy range of 5 - 18 keV (0.7 - 2.5 Å), and a flux at 1 Å of ~10^13 ph/s. Central components of the in-house-developed experimental stations are a 100 nm sphere of confusion goniometer with a horizontal axis, piezo-slits to provide dynamic beam size changes during diffraction experiments, a dedicated secondary goniometer for crystallization plates, and sample- and plate-changing robots. FMX and AMX will support a broad range of biomedical structure determination methods from serial crystallography on micron-sized crystals, to structure determination of complexes in large unit cells, to rapid sample screening and data collection of crystals in trays, for instance to characterize membrane protein crystals and to conduct ligand-binding studies. Together with the solution scattering program at LIX, the new beamlines will offer unique opportunities for advanced diffraction experiments with micro- and mini-beams, with next generation hybrid pixel array detectors and emerging crystal delivery methods such as acoustic droplet ejection. This work is supported by the US National Institutes of Health.


2014 ◽  
Vol 67 (12) ◽  
pp. 1786 ◽  
Author(s):  
Lachlan W. Casey ◽  
Alan E. Mark ◽  
Bostjan Kobe

The role of small-angle X-ray scattering (SAXS) in structural biology is now well established, and its usefulness in combination with macromolecular crystallography is clear. However, the highly averaged SAXS data present a significant risk of over-interpretation to the unwary practitioner, and it can be challenging to frame SAXS results in a manner that maximises the reliability of the conclusions drawn. In this review, a series of recent examples are used to illustrate both the challenges for interpretation and approaches through which these can be overcome.


2007 ◽  
Vol 29 (4) ◽  
pp. 32-35
Author(s):  
Armin Wagner

X-ray diffraction is the method of choice to determine structural information from biological mac romolecules to atomic resolution. This technique depends on the availability of single crystals of protein, which are notoriously difficult to produce. It can take months or even years to find crystal lization conditions capable of producing crystals with sufficient diffraction quality. During the last few years the field of MX (macromolecular crystallography) has undergone considerable change and most of the steps from protein expression to structure solution have been automated, speeding up the process significantly. Facilities such as Diamond Light Source, the new UK synchrotron radia tion source in Oxfordshire, have been developed to incorporate new automation technologies and Diamond will provide an important user resource for XRD (X-ray diffraction) experiments on crystals of biological macromolecules. Furthermore, in collaboration with Professor So Iwata (Imperial College and Diamond Light Source) and funded by the Wellcome Trust, Diamond Light Source is developing a laboratory dedicated specifically to solving the structure of membrane proteins, the crystallization of which poses a particular problem to the crystallographer.


2019 ◽  
Vol 26 (1) ◽  
pp. 170-174 ◽  
Author(s):  
G. Bortel ◽  
G. Faigel ◽  
M. Tegze ◽  
B. Angelov

Atomic resolution X-ray holography can be realized by using the atoms of the sample as inside sources or inside detectors. However, until now there were only very few experiments in which the atoms played the role of inside sources. The reason is twofold: (i) technically, inside-detector experiments are much easier and faster; (ii) by using atoms as inside detectors one can measure holograms at many energies on the same sample, which helps the reconstruction. This paper shows that, using new technical developments, inside-source holograms can be taken much faster than inside-detector holograms and, by applying a sophisticated evaluation method, high-quality reconstruction from a single-energy hologram can also be obtained.


2014 ◽  
Vol 70 (a1) ◽  
pp. C1735-C1735
Author(s):  
James Gorin ◽  
Shaunivan Labiuk ◽  
Julien Cotelesage ◽  
Kathryn Janzen ◽  
Michel Fodje ◽  
...  

The Canadian Macromolecular Crystallography Facility (CMCF) at the Canadian Light Source consists of two macromolecular crystallography beamlines for structure determination using x-ray diffraction. The equipment at the CMCF beamlines have undergone or will undergo changes and improvements to better meet the needs of the most challenging experiments users may present. Among these improvements are: 1) Automounter improvements; 2) Better goniometry on 08ID-1 with the addition of a Huber air-bearing goniometer; 3) Added beam size capabilities on 08ID-1 with the addition of a multiple beam defining aperture holder; 4) XAFS capability on 08B1-1; 5) Improved low energy S-SAD data collection with the addition of a Helium path; 6) Improvements to the data collection and data management software; 7) A vacuum path for scattering experiments with detector distances up to 1 m; 8) A comprehensive beamline upgrade project on the 08ID-1 beamline; and 9) Service crystallography services.


2009 ◽  
Vol 42 (2) ◽  
pp. 333-335 ◽  
Author(s):  
Gordon A. Leonard ◽  
V. Armando Solé ◽  
Antonia Beteva ◽  
José Gabadinho ◽  
Matias Guijarro ◽  
...  

X-ray fluorescence (XRF) measurements on solutions or crystals of biological macromolecules provide additional information that can be used in structure determination and/or refinement protocols. Here details are presented of an experimental setup, employed on all the ESRF Macromolecular Crystallography Group beamlines, that allows the online collection and qualitative analysis of XRF spectra. This experimental setup uses a highly attenuated beam and short exposures, meaning it is minimally destructive but retains high sensitivity.


IUCrJ ◽  
2015 ◽  
Vol 2 (4) ◽  
pp. 464-474 ◽  
Author(s):  
Matthew P. Blakeley ◽  
Samar S. Hasnain ◽  
Svetlana V. Antonyuk

The International Year of Crystallography saw the number of macromolecular structures deposited in the Protein Data Bank cross the 100000 mark, with more than 90000 of these provided by X-ray crystallography. The number of X-ray structures determined to sub-atomic resolution (i.e.≤1 Å) has passed 600 and this is likely to continue to grow rapidly with diffraction-limited synchrotron radiation sources such as MAX-IV (Sweden) and Sirius (Brazil) under construction. A dozen X-ray structures have been deposited to ultra-high resolution (i.e.≤0.7 Å), for which precise electron density can be exploited to obtain charge density and provide information on the bonding character of catalytic or electron transfer sites. Although the development of neutron macromolecular crystallography over the years has been far less pronounced, and its application much less widespread, the availability of new and improved instrumentation, combined with dedicated deuteration facilities, are beginning to transform the field. Of the 83 macromolecular structures deposited with neutron diffraction data, more than half (49/83, 59%) were released since 2010. Sub-mm3crystals are now regularly being used for data collection, structures have been determined to atomic resolution for a few small proteins, and much larger unit-cell systems (cell edges >100 Å) are being successfully studied. While some details relating to H-atom positions are tractable with X-ray crystallography at sub-atomic resolution, the mobility of certain H atoms precludes them from being located. In addition, highly polarized H atoms and protons (H+) remain invisible with X-rays. Moreover, the majority of X-ray structures are determined from cryo-cooled crystals at 100 K, and, although radiation damage can be strongly controlled, especially since the advent of shutterless fast detectors, and by using limited doses and crystal translation at micro-focus beams, radiation damage can still take place. Neutron crystallography therefore remains the only approach where diffraction data can be collected at room temperature without radiation damage issues and the only approach to locate mobile or highly polarized H atoms and protons. Here a review of the current status of sub-atomic X-ray and neutron macromolecular crystallography is given and future prospects for combined approaches are outlined. New results from two metalloproteins, copper nitrite reductase and cytochromec′, are also included, which illustrate the type of information that can be obtained from sub-atomic-resolution (∼0.8 Å) X-ray structures, while also highlighting the need for complementary neutron studies that can provide details of H atoms not provided by X-ray crystallography.


Sign in / Sign up

Export Citation Format

Share Document