Experimental study of roughness spectrum of sandy seafloor with an underwater laser 3D scanning system

Author(s):  
Guangming Kan ◽  
Jingqiang Wang ◽  
Xiangmei Meng ◽  
Zhiguo Yang ◽  
Shengqi Yu ◽  
...  
1991 ◽  
Author(s):  
Roswell W. Austin ◽  
Seibert Q. Duntley ◽  
Richard L. Ensminger ◽  
Theodore J. Petzold ◽  
Raymond C. Smith

Author(s):  
Pablo Cazenave ◽  
Katina Tiñacos ◽  
Ming Gao ◽  
Richard Kania ◽  
Rick Wang

New technologies for in-ditch non-destructive evaluation were lately developed and are becoming of mainstream use in the evaluation of external corrosion features for both In-Line-Inspection performance evaluation and pipeline integrity assessment. However, doubt was cast about the reliability and repeatability of these new technologies (hardware and processing software) when compared with those used in the traditional external-corrosion in-ditch measurement and the reliability of the pipeline integrity assessment calculations (PBurst) embedded in their software when compared with industry-wide accepted calculation methods. Therefore, the primary objective of this study is to evaluate the variation and repeatability of the measurements produced by these new technologies in corrosion feature profiling and associated PBurst calculations. Two new 3D scanning systems were used for the evaluation of two pipe samples removed from service which contain complex external corrosion features in laboratory. The reliability of the 3D scanning system in measuring corrosion profiles was evaluated against traditional profile gage data. In addition, the associated burst pressures reported by the systems were compared with results obtained using industry-widely used calculation methods. Also, consistencies, errors and gaps in results were identified. In this paper, the approach used for this study is described first, the evaluation results are then presented and finally the findings and their implications are discussed.


Sensors ◽  
2020 ◽  
Vol 20 (14) ◽  
pp. 3847 ◽  
Author(s):  
Sylwia Dabrowska ◽  
Martyna Ekiert ◽  
Kaja Wojcik ◽  
Marek Kalemba ◽  
Andrzej Mlyniec

In this article, we present the design and validation of a non-contact scanning system for the development of a three-dimensional (3D) model of moist biological samples. Due to the irregular shapes and low stiffness of soft tissue samples, the use of a non-contact, reliable geometry scanning system with good accuracy and repeatability is required. We propose a reliable 3D scanning system consisting of a blue light profile sensor, stationary and rotating frames with stepper motors, gears and a five-phase stepping motor unit, single-axis robot, control system, and replaceable sample grips, which once mounted onto the sample, are used for both scanning and mechanical tests. The proposed system was validated by comparison of the cross-sectional areas calculated based on 3D models, digital caliper, and vision-based methods. Validation was done on regularly-shaped samples, a wooden twig, as well as tendon fascicle bundles. The 3D profiles were used for the development of the 3D computational model of the sample, including surface concavities. Our system allowed for 3D model development of samples with a relative error of less than 1.2% and high repeatability in approximately three minutes. This was crucial for the extraction of the mechanical properties and subsequent inverse analysis, enabling the calibration of complex material models.


Sign in / Sign up

Export Citation Format

Share Document