Effects of concrete grade and steel yield strength on flexural ductility of reinforced concrete beams

2004 ◽  
Vol 5 (2) ◽  
pp. 1-20 ◽  
Author(s):  
A.K.H. Kwan ◽  
J.C.M. Ho ◽  
H.J. Pam
2019 ◽  
Vol 10 (4) ◽  
pp. 457-469 ◽  
Author(s):  
Avraham N Dancygier ◽  
Yuri S Karinski

This article presents a study of cracking localization in normal and high strength concrete beams that include steel fibers and the influence of this localization on their structural ductility. It is shown that for a given fiber type and content, as the reinforcement ratio ρ decreases, the cracking localization level increases. The effect of ρ on the level of cracking localization is more pronounced for low amounts of conventional reinforcement. This range of conventional reinforcement ratio is typical of slabs and especially for the commonly thicker protective slabs. Examination of the effect of the reinforcement ratio on the flexural ductility shows that there exists a transition point below which the ductility ratio decreases with  ρ. This transition point is well above the minimum reinforcement ratio, which is required in design codes for plain reinforced concrete elements. Empirical analysis of the relation between cracking localization and ductility ratio shows that up to the same transition point, as cracking localization increases, the flexural ductility decreases. Findings of this study show that the positive effect of adding fibers on enhancing the impact resistance of slabs and beams is conflicted by their negative influence on reducing the structural ductility for low reinforcement ratios, which are typical of protective slabs.


Author(s):  
Nazar Oukaili ◽  
Mohammed Khattab

For structural concrete members that may expose to serious earthquake, overload or accident impact, the design of ductility must be given the same importance as the flexural strength. The aim of this investigation is to study the change in ductility of structural concrete flexural members during their exposure to limited cycles of repeated loading. Twenty full-scale beam specimens have been fabricated in to two identical groups; each group consisted of ten specimens. The first group was tested under monotonic static loading to failure and regarded as control beams, while the specimens of the second group were subjected to ten cycles of repeated loading with constant load interval, which ranged between 40% and 60% of ultimate load. Specimens in each group were categorized as follows: two traditional reinforced concrete specimens with different intensity of tension reinforcement; three partially prestressed specimens with bonded strands; three partially prestressed specimens with unbonded strands; and two fully prestressed concrete specimens. The main variable, which was considered for all specimens was the partial prestressing ratio (PPR). It was observed that, the ductility of reinforced concrete beams was insignificantly increased during subjecting to limited repeated loading. For fully prestressed and partially prestressed concrete beams with high level of PPR, the ductility was significantly enhanced, while, it was decreased for specimens with small level of PPR.


2014 ◽  
Vol 41 (7) ◽  
pp. 594-604 ◽  
Author(s):  
Mehrollah Rakhshanimehr ◽  
M. Reza Esfahani ◽  
M. Reza Kianoush ◽  
B. Ali Mohammadzadeh ◽  
S. Roohollah Mousavi

In this paper, the flexural ductility of lap-spliced reinforced concrete (RC) beams is experimentally investigated. Twenty-four specimens were designed and manufactured for laboratory experiments. Concrete compressive strength, amount of transverse reinforcement over the splice length, and the diameter of longitudinal bars were selected as the main variables. The ductility of tested specimens is evaluated based on a previously defined ductility ratio. Results show that concrete strength and amount of transverse reinforcement over the splice have major effects on ductility. With an appropriate amount of transverse reinforcement, a satisfactory ductility response for different concrete strengths can be obtained. The CSA-A23.3-04 Standard provisions on bond strength and ductility of lap-spliced RC beams are evaluated and discussed. This study shows that the provisions in predicting the bond strength of lap-spliced concrete beams are adequate but may not achieve a satisfactory performance for ductility. An equation is proposed to achieve the appropriate ductility.


Sign in / Sign up

Export Citation Format

Share Document