Active vibration control of composite plate with optimal placement of piezoelectric patches

2017 ◽  
Vol 26 (4) ◽  
pp. 341-349 ◽  
Author(s):  
K. Bendine ◽  
F. B. Boukhoulda ◽  
B. Haddag ◽  
M. Nouari
2005 ◽  
Vol 128 (2) ◽  
pp. 256-260 ◽  
Author(s):  
Xianmin Zhang ◽  
Arthur G. Erdman

The optimal placement of sensors and actuators in active vibration control of flexible linkage mechanisms is studied. First, the vibration control model of the flexible mechanism is introduced. Second, based on the concept of the controllability and the observability of the controlled subsystem and the residual subsystem, the optimal model is developed aiming at the maximization of the controllability and the observability of the controlled modes and minimization of those of the residual modes. Finally, a numerical example is presented, which shows that the proposed method is feasible. Simulation analysis shows that to achieve the same control effect, the control system is easier to realize if the sensors and actuators are located in the optimal positions.


2017 ◽  
Vol 28 (18) ◽  
pp. 2603-2616 ◽  
Author(s):  
Asif Khan ◽  
Hyun Sung Lee ◽  
Heung Soo Kim

In this article, the effect of a sensor-debonding failure on the active vibration control of a smart composite plate is investigated numerically. A mathematical model of the smart structure with a partially debonded piezoelectric sensor is developed using an improved layerwise theory, a higher-order electric-potential field that serves as the displacement field, and the potential variation through the piezoelectric patches. A state-space form that is based on the reduced-order model is employed for the controller design. A control strategy with a constant gain and velocity feedback is used to assess the vibration-control characteristics of the controller in the presence of the sensor-debonding failure. The obtained results show that sensor-debonding failure reduces the sensor-output, control-input signal, and active damping in magnitude that successively degrades the vibration attenuation capability of the active vibration controller. The settling time and relative tip displacement of the controlled structure increase with the increasing length of partial debonding between the piezoelectric sensor and host structure. Furthermore, a damage-sensitive feature along with multidimensional scaling showed excellent results for the detection and quantification of sensor-debonding failure in the active vibration control of smart structures.


2009 ◽  
Vol 419-420 ◽  
pp. 173-176
Author(s):  
Wei Yuan Wang ◽  
Kai Xue ◽  
Dong Yan Shi

The purpose of this paper is to investigate the optimal placement of piezoelectric actuator for active vibration control of smart structure. The structures can be described in the modal space based on the independent modal space control method and dynamic equations derived from finite element model. The modal damping ratios are derived from modal equations and an optimal target is given by maximizing the modal damping ratios. Accumulation method is adopted to the optimization calculation. Simulations are carried out for active vibration control of a conical shell with distributed piezoelectric actuators. Control effects proved the validity of the optimal method above by compared with the non-optimal results. The optimal method in this paper gives a useful guide for quantity optimization of actuators to piezoelectric structures.


2007 ◽  
Vol 301 (3-5) ◽  
pp. 521-543 ◽  
Author(s):  
Zhi-cheng Qiu ◽  
Xian-min Zhang ◽  
Hong-xin Wu ◽  
Hong-hua Zhang

2011 ◽  
Vol 34 (7) ◽  
pp. 815-828 ◽  
Author(s):  
Xiaojin Zhu ◽  
Zhiyuan Gao ◽  
Quanzhen Huang ◽  
Shouwei Gao ◽  
Enyu Jiang

This correspondence focuses on the analysis and implementation of multi-input multi-output (MIMO) filtered-u least mean square (FULMS) algorithm for active vibration suppression of a cantilever smart beam with surface bonded lead zirconate titanate patches. By analysing a single-input single-output FULMS algorithm, the MIMO FULMS controller structure is given. Then an active vibration control experimental platform is established, with optimal placement of the actuators and sensors based on the maximal modal force rule. Simulation contrast analysis of FULMS algorithm and the most famous filtered-x least mean square (FXLMS) algorithm is performed while the reference signal is extracted from the exciter as well as directly from the controlled structure. Simulation results show that if the feedback information reflects the reference signal collected by the reference transducers, the FXLMS controller could hardly suppress the vibration while the FULMS controller is still effective. Then the actual control experiment is performed, and the result confirms the simulation results. The designed MIMO FULMS vibration controller has a good control performance, suppressing the vibration significantly with rapid convergence.


Sign in / Sign up

Export Citation Format

Share Document