Investigation of the titanium superconducting transition as a temperature reference point below 0.65 K

Metrologia ◽  
2000 ◽  
Vol 37 (3) ◽  
pp. 229-233 ◽  
Author(s):  
A Peruzzi ◽  
E Gottardi ◽  
F Pavese ◽  
I Peroni ◽  
G Ventura
2019 ◽  
Vol 61 (12) ◽  
pp. 1159-1165
Author(s):  
B. B. Khlevnoy ◽  
I. A. Grigor’eva ◽  
E. A. Ivashin ◽  
S. A. Ogarev ◽  
V. I. Sapritsky

1988 ◽  
Vol 102 ◽  
pp. 41
Author(s):  
E. Silver ◽  
C. Hailey ◽  
S. Labov ◽  
N. Madden ◽  
D. Landis ◽  
...  

The merits of microcalorimetry below 1°K for high resolution spectroscopy has become widely recognized on theoretical grounds. By combining the high efficiency, broadband spectral sensitivity of traditional photoelectric detectors with the high resolution capabilities characteristic of dispersive spectrometers, the microcalorimeter could potentially revolutionize spectroscopic measurements of astrophysical and laboratory plasmas. In actuality, however, the performance of prototype instruments has fallen short of theoretical predictions and practical detectors are still unavailable for use as laboratory and space-based instruments. These issues are currently being addressed by the new collaborative initiative between LLNL, LBL, U.C.I., U.C.B., and U.C.D.. Microcalorimeters of various types are being developed and tested at temperatures of 1.4, 0.3, and 0.1°K. These include monolithic devices made from NTD Germanium and composite configurations using sapphire substrates with temperature sensors fabricated from NTD Germanium, evaporative films of Germanium-Gold alloy, or material with superconducting transition edges. A new approache to low noise pulse counting electronics has been developed that allows the ultimate speed of the device to be determined solely by the detector thermal response and geometry. Our laboratory studies of the thermal and resistive properties of these and other candidate materials should enable us to characterize the pulse shape and subsequently predict the ultimate performance. We are building a compact adiabatic demagnetization refrigerator for conveniently reaching 0.1°K in the laboratory and for use in future satellite-borne missions. A description of this instrument together with results from our most recent experiments will be presented.


Author(s):  
M. A. Kirk ◽  
M. C. Baker ◽  
B. J. Kestel ◽  
H. W. Weber

It is well known that a number of compound superconductors with the A15 structure undergo a martensite transformation when cooled to the superconducting state. Nb3Sn is one of those compounds that transforms, at least partially, from a cubic to tetragonal structure near 43 K. To our knowledge this transformation in Nb3Sn has not been studied by TEM. In fact, the only low temperature TEM study of an A15 material, V3Si, was performed by Goringe and Valdre over 20 years ago. They found the martensite structure in some foil areas at temperatures between 11 and 29 K, accompanied by faults that consisted of coherent twin boundaries on {110} planes. In pursuing our studies of irradiation defects in superconductors, we are the first to observe by TEM a similar martensite structure in Nb3Sn.Samples of Nb3Sn suitable for TEM studies have been produced by both a liquid solute diffusion reaction and by sputter deposition of thin films.


2018 ◽  
Vol 39 (2) ◽  
pp. 99-106 ◽  
Author(s):  
Michał Białek ◽  
Przemysław Sawicki

Abstract. In this work, we investigated individual differences in cognitive reflection effects on delay discounting – a preference for smaller sooner over larger later payoff. People are claimed to prefer more these alternatives they considered first – so-called reference point – over the alternatives they considered later. Cognitive reflection affects the way individuals process information, with less reflective individuals relying predominantly on the first information they consider, thus, being more susceptible to reference points as compared to more reflective individuals. In Experiment 1, we confirmed that individuals who scored high on the Cognitive Reflection Test discount less strongly than less reflective individuals, but we also show that such individuals are less susceptible to imposed reference points. Experiment 2 replicated these findings additionally providing evidence that cognitive reflection predicts discounting strength and (in)dependency to reference points over and above individual difference in numeracy.


Author(s):  
Amber N. Bloomfield ◽  
Jessica M. Choplin
Keyword(s):  

1978 ◽  
Vol 39 (C6) ◽  
pp. C6-448-C6-450 ◽  
Author(s):  
M. W. Young ◽  
J. M.D. Thomas ◽  
C. J. Adkins ◽  
J. W. Tate

Author(s):  
Galina Kuzichkina ◽  
Alexander Mazuritsky

The authors discuss the problems of library and information education. The lack of a single system of life-long education in the library industry is stressed. The Model Standard of Public Libraries as a reference point for education reinvention is analyzed. The main vectors of public libraries activities defined in the Model Standard are considered, along with the desirable professional competences. The ratio of the libraries’ main tasks and functionalities and the professional education is examined.


Sign in / Sign up

Export Citation Format

Share Document