Current densities in a 2 mm resolution anatomically realistic model of the body induced by low frequency electric fields

2000 ◽  
Vol 45 (4) ◽  
pp. 1013-1022 ◽  
Author(s):  
P J Dimbylow
2010 ◽  
Vol 6 (1) ◽  
pp. 31 ◽  
Author(s):  
Cristina Peratta ◽  
Andres Peratta ◽  
Dragan Poljak

The paper introduces a three dimensional multidomainboundary element model of a pregnant woman and foetus for the analysis of exposure to high voltage extremely low frequency electric fields. The definition of the differentphysical and geometrical properties of the relevant tissues is established according to medical information available in existing literature. The model takes into account changes in geometry, body mass, body fat, and overall chemical composition in the body which influence the electrical properties, throughout the different gestational periods. The developed model is used to solve the case of exposure to overhead power transmission lines at different stages of pregnancy including weeks 8, 13, 26 and 38. The results obtained are in line with those published in the earlier works considering different approaches. In addition, a sensitivity analysis involving varying scenarios of conductivity, foetus postures and geometry for each stage is defined and solved. Finally, a correlation between the externally applied electric field and the current density inside the foetus is established and the zones of maximum exposure are identified.


2013 ◽  
Vol 341-342 ◽  
pp. 581-585
Author(s):  
Gui Sheng Tao ◽  
Ling Xia ◽  
Min Hua Zhu ◽  
Xia Li ◽  
Wen Long Xu

This paper studies induced electric fields and current densities for peripheral nerve stimulation (PNS) induced by breast gradient coils. The numerical calculations are based on an efficient, quasi-static, finite-difference (QSFD) scheme. The application of the human body to the calculations of induced current densities and electric fields from applied low frequency magnetic and electric fields is described. The spatial distributions of the induced electric field and their gradients are calculated. This study provides some insight into the spatial characteristics of the induced field gradients for PNS in MRI, which may be used to further evaluate the sites where magnetic stimulation is likely to occur and to optimize gradient coil design.


2001 ◽  
Vol 204 (2) ◽  
pp. 185-198 ◽  
Author(s):  
P.A. Aguilera ◽  
M.E. Castello ◽  
A.A. Caputi

Local electric fields generated by the electric organ discharge of Gymnotus carapo were explored at selected points on the skin of an emitter fish (‘local self-generated fields’) and on the skin of a conspecific (‘local conspecific-generated fields’) using a specially designed probe. Local self-generated fields showed a constant pattern along the body of the fish. At the head, these fields were collimated, much stronger than elsewhere on the fish, and had a time waveform that was site-independent. This waveform consisted of a slow head-negative wave followed by a faster head-positive wave. In contrast, time waveforms in the trunk and tail regions were site-specific, with field vectors that changed direction over time. Local conspecific-generated fields were similar to the head-to-tail field, but their spatio-temporal pattern at the skin depended on the relative orientation between the receiving fish and the emitting fish. Because self-generated fields had a slow early component at the head region, they displayed a low-frequency peak in their power spectral density histograms. In contrast, the conspecific-generated fields had time waveforms with a sharper phase reversal, resulting in a peak at higher frequency than in the self-generated field. Lesions in emitting fish demonstrated that waveform components generated by the trunk and tail regions of the electric organ predominate in conspecific-generated fields, whereas waveform components generated by the abdominal region prevail in self-generated fields. Similar results were obtained from Brachyhypopomus pinnicaudatus. These results suggest that, in pulse-emitting gymnotids, electrolocation and electrocommunication signals may be carried by different field components generated by different regions of the electric organ.


1990 ◽  
Vol 111 (1) ◽  
pp. 299-305 ◽  
Author(s):  
A. I. Bezhanova ◽  
V. I. Silvestrov ◽  
T. A. Zeinalova ◽  
T. R. Volk

2021 ◽  
Vol 14 (1) ◽  
Author(s):  
Anna Gorsler ◽  
Ulrike Grittner ◽  
Nadine Külzow ◽  
Torsten Rackoll

Abstract Objective Neglect after stroke is a disabling disorder and its rehabilitation is a major challenge. Transcranial direct current stimulation (tDCS) seems to be a promising adjuvant technique to improve standard care neglect therapy. Since electric fields are influenced by age-related factors, higher current densities are probably needed for effective treatment in aged stroke patients. Validation of treatment efficacy requires sham-controlled experiments, but increased current densities might comprise blinding. Therefore, a pilot study was conducted to test sham adequacy when using current density of 0.8 A/m2. Whether especially neglect patients who mainly suffer from perceptual and attentional deficits are able to differentiate beyond chance active from sham tDCS was investigated in a randomized cross-over design (active/sham stimulation) in 12 early subacute patients with left-sided hemineglect. Stimulation (0.8 A/m2) was performed simultaneous to standard care neglect therapy. Results Odds ratio of correct guessing an atDCS condition compared to wrongly judge an atDCS condition as sham was 10.00 (95%CI 0.65–154.40, p = 0.099). However, given the small sample size and high OR, although likely somewhat overestimated, results require careful interpretation and blinding success in neglect studies with current densities of 0.8 A/m2 should be further confirmed.


2021 ◽  
Vol 0 (0) ◽  
Author(s):  
Martin L. Pall

Abstract Millimeter wave (MM-wave) electromagnetic fields (EMFs) are predicted to not produce penetrating effects in the body. The electric but not magnetic part of MM-EMFs are almost completely absorbed within the outer 1 mm of the body. Rodents are reported to have penetrating MM-wave impacts on the brain, the myocardium, liver, kidney and bone marrow. MM-waves produce electromagnetic sensitivity-like changes in rodent, frog and skate tissues. In humans, MM-waves have penetrating effects including impacts on the brain, producing EEG changes and other neurological/neuropsychiatric changes, increases in apparent electromagnetic hypersensitivity and produce changes on ulcers and cardiac activity. This review focuses on several issues required to understand penetrating effects of MM-waves and microwaves: 1. Electronically generated EMFs are coherent, producing much higher electrical and magnetic forces then do natural incoherent EMFs. 2. The fixed relationship between electrical and magnetic fields found in EMFs in a vacuum or highly permeable medium such as air, predicted by Maxwell’s equations, breaks down in other materials. Specifically, MM-wave electrical fields are almost completely absorbed in the outer 1 mm of the body due to the high dielectric constant of biological aqueous phases. However, the magnetic fields are very highly penetrating. 3. Time-varying magnetic fields have central roles in producing highly penetrating effects. The primary mechanism of EMF action is voltage-gated calcium channel (VGCC) activation with the EMFs acting via their forces on the voltage sensor, rather than by depolarization of the plasma membrane. Two distinct mechanisms, an indirect and a direct mechanism, are consistent with and predicted by the physics, to explain penetrating MM-wave VGCC activation via the voltage sensor. Time-varying coherent magnetic fields, as predicted by the Maxwell–Faraday version of Faraday’s law of induction, can put forces on ions dissolved in aqueous phases deep within the body, regenerating coherent electric fields which activate the VGCC voltage sensor. In addition, time-varying magnetic fields can directly put forces on the 20 charges in the VGCC voltage sensor. There are three very important findings here which are rarely recognized in the EMF scientific literature: coherence of electronically generated EMFs; the key role of time-varying magnetic fields in generating highly penetrating effects; the key role of both modulating and pure EMF pulses in greatly increasing very short term high level time-variation of magnetic and electric fields. It is probable that genuine safety guidelines must keep nanosecond timescale-variation of coherent electric and magnetic fields below some maximum level in order to produce genuine safety. These findings have important implications with regard to 5G radiation.


Sign in / Sign up

Export Citation Format

Share Document