Iterative dynamic dual-energy CT algorithm in reducing statistical noise in multi-energy CT imaging

Author(s):  
Yidi Yao ◽  
Liang Li ◽  
Zhiqiang Chen

Abstract Multi-energy spectral CT has a broader range of applications with the recent development of photon-counting detectors. However, the photons counted in each energy bin decrease when the number of energy bins increases, which causes a higher statistical noise level of the CT image. In this work, we propose a novel iterative dynamic dual-energy CT algorithm to reduce the statistical noise. In the proposed algorithm, the multi-energy projections are estimated from the dynamic dual-energy CT data during the iterative process. The proposed algorithm is verified on sufficient numerical simulations and a laboratory two-energy-threshold PCD system. By applying the same reconstruction algorithm, the dynamic dual-energy CT's final reconstruction results have a much lower statistical noise level than the conventional multi-energy CT. Moreover, based on the analysis of the simulation results, we explain why the dynamic dual-energy CT has a lower statistical noise level than the conventional multi-energy CT. The reason is that: the statistical noise level of multi-energy projection estimated with the proposed algorithm is much lower than that of the conventional multi-energy CT, which leads to less statistical noise of the dynamic dual-energy CT imaging.

2021 ◽  
Vol 70 ◽  
pp. 102001
Author(s):  
Tianling Lyu ◽  
Wei Zhao ◽  
Yinsu Zhu ◽  
Zhan Wu ◽  
Yikun Zhang ◽  
...  

2022 ◽  
Vol 17 (01) ◽  
pp. C01028
Author(s):  
J. Dudak ◽  
J. Zemlicka

Abstract X-ray micro-CT has become a popular and widely used tool for the purposes of scientific research. Although the current state-of-the-art micro-CT is on a high technology level, it still has some known limitations. One of the relevant issues is an inability to clearly identify and quantify specific materials. The mentioned drawback can be solved by the energy-sensitive CT approach. Dual-energy CT, which is already frequently used in human medicine, offers the identification of two different materials; for example, it differentiates an intravenous contrast agent from bone or it can indicate the composition of urinary stones. Resolving a larger number of material components within a single object is beyond the capabilities of dual-energy CT. Such an approach requires a higher number of measurements using different photon energies. A possible solution for multi bin, or so-called spectral CT, is the application of photon-counting detectors. Photon counting technology offers an integrated circuitry capable of resolving the energy of incoming photons in each pixel. Therefore, it is possible to collect data in user-defined energy windows. This contribution evaluates the applicability of the large-area photon-counting detector Timepix for multi bin energy-sensitive micro-CT. It presents an experimental phantom study focused on the simultaneous K-edge-based identification and quantification of multiple contrast agents within a single object. The paper describes the collection of multiple energy bins using the Timepix detector operated in the photon counting mode, explains the data processing, and demonstrates the results obtained from an in-house implemented basis material decomposition algorithm.


2014 ◽  
Vol 83 (7) ◽  
pp. 1216-1221 ◽  
Author(s):  
Shaowei Zheng ◽  
Yue Dong ◽  
Yanwei Miao ◽  
Ailian Liu ◽  
Xin Zhang ◽  
...  

Author(s):  
S. Sawall ◽  
L. Klein ◽  
E. Wehrse ◽  
L. T. Rotkopf ◽  
C. Amato ◽  
...  

Abstract Objective To evaluate the dual-energy (DE) performance and spectral separation with respect to iodine imaging in a photon-counting CT (PCCT) and compare it to dual-source CT (DSCT) DE imaging. Methods A semi-anthropomorphic phantom extendable with fat rings equipped with iodine vials is measured in an experimental PCCT. The system comprises a PC detector with two energy bins (20 keV, T) and (T, eU) with threshold T and tube voltage U. Measurements using the PCCT are performed at all available tube voltages (80 to 140 kV) and threshold settings (50–90 keV). Further measurements are performed using a conventional energy-integrating DSCT. Spectral separation is quantified as the relative contrast media ratio R between the energy bins and low/high images. Image noise and dose-normalized contrast-to-noise ratio (CNRD) are evaluated in resulting iodine images. All results are validated in a post-mortem angiography study. Results R of the PC detector varies between 1.2 and 2.6 and increases with higher thresholds and higher tube voltage. Reference R of the EI DSCT is found as 2.20 on average overall phantoms. Maximum CNRD in iodine images is found for T = 60/65/70/70 keV for 80/100/120/140 kV. The highest CNRD of the PCCT is obtained using 140 kV and is decreasing with decreasing tube voltage. All results could be confirmed in the post-mortem angiography study. Conclusion Intrinsically acquired DE data are able to provide iodine images similar to conventional DSCT. However, PCCT thresholds should be chosen with respect to tube voltage to maximize image quality in retrospectively derived image sets. Key Points • Photon-counting CT allows for the computation of iodine images with similar quality compared to conventional dual-source dual-energy CT. • Thresholds should be chosen as a function of the tube voltage to maximize iodine contrast-to-noise ratio in derived image sets. • Image quality of retrospectively computed image sets can be maximized using optimized threshold settings.


Stroke ◽  
2021 ◽  
Vol 52 (Suppl_1) ◽  
Author(s):  
Tri Huynh* ◽  
Niran Vijayaraghavan* ◽  
Hannah Branstetter ◽  
Natalie Buchwald ◽  
Justin De Prey ◽  
...  

Introduction: Hyperintense acute reperfusion marker (HARM) has been identified on post-contrast magnetic resonance imaging (MRI) to be a marker of hemorrhagic conversion (HC) post reperfusion therapy in acute stroke patients. We have previously described a case where MRI HARM was mimicked on post contrast computed topography (CT) imaging in an acute stroke patient post reperfusion. Dual-Energy (DECT) allows for differentiation between acute blood and iodine contrast extravasation (ICE), and thus can have utility when ICE is present. Here we sought to validate whether post-intervention ICE/CT hyperdensity reperfusion maker (CT HARM), and contrast subtracted on DECT is associated with HC in acute stroke patients. Method: Data was obtained from our Institutional Review Board approved stroke admission database from January 2017 to November 2019, including ischemic stroke patients that received thrombolysis or thrombectomy, had evaluable images within 24 hours of admission, and received a DECT. Ischemic volumes of the stroke was measured on diffusion-weighted image (DWI). ICE was measured on CT head and DECT using the freehand 3D region of interest tool on the Visage Imaging PACS System. Susceptibility weighted MRI sequences were used to grade HC. Data analysis was conducted with regression modeling. Results: A total of 82 patients were included, 49% women, median age 73 (interquartile range (IQR), 61- 77), admission NIHSS 12 (IQR, 7 - 21), 24 hour change in NIHSS 4 (IQR, 0 -13), glucose 125 (IQR, 106 -158), creatinine 1.0 (IQR, 0.8 - 1.2), infarct volume 50.6 ± 7.1 mL, 48% treated with thrombectomy, 7% with PH-1 or PH-2 identified on MRI, and 56% with MCA infarcts. ICE volume was 2.6 ± 1.0 mL and DECT volume was 2.2 ± 1.1mL. ICE increased the likelihood of MRI confirmed PH-1 or PH-2 hemorrhagic conversion (odds ratio (OR) 14.34, 95% confidence interval (CI) 5.74 - 22.94) and decreased likelihood of increase in NIHSS at 24 hours (OR 0.20, 95% CI 0.01 to 0.40). There were no other significant associations with ICE or DECT volumes. Conclusion: Our results are supportive of our proposed association between CT HARM and risk of HC. More studies are needed to study whether quantitative of DECT can be predictive of stroke outcomes post reperfusion therapy.