Multi bin energy-sensitive micro-CT using large area photon-counting detectors Timepix

2022 ◽  
Vol 17 (01) ◽  
pp. C01028
Author(s):  
J. Dudak ◽  
J. Zemlicka

Abstract X-ray micro-CT has become a popular and widely used tool for the purposes of scientific research. Although the current state-of-the-art micro-CT is on a high technology level, it still has some known limitations. One of the relevant issues is an inability to clearly identify and quantify specific materials. The mentioned drawback can be solved by the energy-sensitive CT approach. Dual-energy CT, which is already frequently used in human medicine, offers the identification of two different materials; for example, it differentiates an intravenous contrast agent from bone or it can indicate the composition of urinary stones. Resolving a larger number of material components within a single object is beyond the capabilities of dual-energy CT. Such an approach requires a higher number of measurements using different photon energies. A possible solution for multi bin, or so-called spectral CT, is the application of photon-counting detectors. Photon counting technology offers an integrated circuitry capable of resolving the energy of incoming photons in each pixel. Therefore, it is possible to collect data in user-defined energy windows. This contribution evaluates the applicability of the large-area photon-counting detector Timepix for multi bin energy-sensitive micro-CT. It presents an experimental phantom study focused on the simultaneous K-edge-based identification and quantification of multiple contrast agents within a single object. The paper describes the collection of multiple energy bins using the Timepix detector operated in the photon counting mode, explains the data processing, and demonstrates the results obtained from an in-house implemented basis material decomposition algorithm.

Author(s):  
Yidi Yao ◽  
Liang Li ◽  
Zhiqiang Chen

Abstract Multi-energy spectral CT has a broader range of applications with the recent development of photon-counting detectors. However, the photons counted in each energy bin decrease when the number of energy bins increases, which causes a higher statistical noise level of the CT image. In this work, we propose a novel iterative dynamic dual-energy CT algorithm to reduce the statistical noise. In the proposed algorithm, the multi-energy projections are estimated from the dynamic dual-energy CT data during the iterative process. The proposed algorithm is verified on sufficient numerical simulations and a laboratory two-energy-threshold PCD system. By applying the same reconstruction algorithm, the dynamic dual-energy CT's final reconstruction results have a much lower statistical noise level than the conventional multi-energy CT. Moreover, based on the analysis of the simulation results, we explain why the dynamic dual-energy CT has a lower statistical noise level than the conventional multi-energy CT. The reason is that: the statistical noise level of multi-energy projection estimated with the proposed algorithm is much lower than that of the conventional multi-energy CT, which leads to less statistical noise of the dynamic dual-energy CT imaging.


2018 ◽  
Vol 13 (12) ◽  
pp. C12006-C12006 ◽  
Author(s):  
D. Vavřík ◽  
D. Kytýř ◽  
S. Mühleder ◽  
M. Vopálenský ◽  
P. Beneš ◽  
...  

PLoS ONE ◽  
2019 ◽  
Vol 14 (7) ◽  
pp. e0219659 ◽  
Author(s):  
Thorsten Sellerer ◽  
Sebastian Ehn ◽  
Korbinian Mechlem ◽  
Manuela Duda ◽  
Michael Epple ◽  
...  

2016 ◽  
Vol 11 (02) ◽  
pp. C02003-C02003 ◽  
Author(s):  
I. Kumpová ◽  
D. Vavřík ◽  
T. Fíla ◽  
P. Koudelka ◽  
I. Jandejsek ◽  
...  

2020 ◽  
pp. neurintsurg-2020-016799
Author(s):  
Yong-Hong Ding ◽  
Mehdi Abbasi ◽  
Gregory Michalak ◽  
Shuai Leng ◽  
Daying Dai ◽  
...  

BackgroundCT is the most commonly used imaging modality for acute ischemic stroke evaluation. There is growing interest to use pre-operative imaging to characterize clot composition in stroke. We performed an in-vitro study examining the ability of various CT techniques in differentiation between different clot types.MethodsFive clot types with varying fibrin and red blood cells (RBCs) densities (5% RBC and 95% fibrin; 25% RBC and 75% fibrin; 50% RBC and 50% fibrin; 75% RBC and 25% fibrin; 95% RBC and 5% fibrin) were prepared and scanned using various CT scanning protocols (single-energy, dual-energy, photon-counting detector CT, mixed images, and virtual monoenergetic images). Martius Scarlett Blue trichrome staining was performed to confirm the composition of each clot. Mean CT values of each type of clot under different scanning protocol were calculated and compared.ResultsMean CT values of the CT numbers in the five clot specimens for 5%, 25%, and 50% RBC clot were similar across modalities, and increased significantly for 75% and 95% RBC clots (P<0.0001). Mean CT values are highest in the Mono +50 keV images in each type of clot, and they were also significantly higher than all other imaging protocols (P<0.001). Dual-energy CT with Mono +50 keV images showed the greatest difference between attenuation in each type of clot.ConclusionMono +50 keV dual-energy CT scan may be helpful for differentiating between RBC-rich and fibrin-rich thrombi seen in large-vessel occlusion patients.


Author(s):  
S. Sawall ◽  
L. Klein ◽  
E. Wehrse ◽  
L. T. Rotkopf ◽  
C. Amato ◽  
...  

Abstract Objective To evaluate the dual-energy (DE) performance and spectral separation with respect to iodine imaging in a photon-counting CT (PCCT) and compare it to dual-source CT (DSCT) DE imaging. Methods A semi-anthropomorphic phantom extendable with fat rings equipped with iodine vials is measured in an experimental PCCT. The system comprises a PC detector with two energy bins (20 keV, T) and (T, eU) with threshold T and tube voltage U. Measurements using the PCCT are performed at all available tube voltages (80 to 140 kV) and threshold settings (50–90 keV). Further measurements are performed using a conventional energy-integrating DSCT. Spectral separation is quantified as the relative contrast media ratio R between the energy bins and low/high images. Image noise and dose-normalized contrast-to-noise ratio (CNRD) are evaluated in resulting iodine images. All results are validated in a post-mortem angiography study. Results R of the PC detector varies between 1.2 and 2.6 and increases with higher thresholds and higher tube voltage. Reference R of the EI DSCT is found as 2.20 on average overall phantoms. Maximum CNRD in iodine images is found for T = 60/65/70/70 keV for 80/100/120/140 kV. The highest CNRD of the PCCT is obtained using 140 kV and is decreasing with decreasing tube voltage. All results could be confirmed in the post-mortem angiography study. Conclusion Intrinsically acquired DE data are able to provide iodine images similar to conventional DSCT. However, PCCT thresholds should be chosen with respect to tube voltage to maximize image quality in retrospectively derived image sets. Key Points • Photon-counting CT allows for the computation of iodine images with similar quality compared to conventional dual-source dual-energy CT. • Thresholds should be chosen as a function of the tube voltage to maximize iodine contrast-to-noise ratio in derived image sets. • Image quality of retrospectively computed image sets can be maximized using optimized threshold settings.