Facile and controllable synthesis of molybdenum disulfide quantum dots for highly sensitive and selective sensing of copper ions

2018 ◽  
Vol 27 (5) ◽  
pp. 056104 ◽  
Author(s):  
Xue Li ◽  
Da-Wei He ◽  
Yong-Sheng Wang ◽  
Yin Hu ◽  
Xuan Zhao ◽  
...  
The Analyst ◽  
2019 ◽  
Vol 144 (8) ◽  
pp. 2604-2610 ◽  
Author(s):  
Peng Jiang ◽  
Shulan Li ◽  
Minlu Han ◽  
Yi Liu ◽  
Zilin Chen

An Ag2S QD fluorescent sensor for highly selective and sensitive Cu2+ detection was developed and the quenching mechanism was investigated.


2020 ◽  
Vol 16 (6) ◽  
pp. 744-752
Author(s):  
Kuan Luo ◽  
Xinyu Jiang

Background: Diabetes Mellitus (DM) is a major public metabolic disease that influences 366 million people in the world in 2011, and this number is predicted to rise to 552 million in 2030. DM is clinically diagnosed by a fasting blood glucose that is equal or greater than 7 mM. Therefore, the development of effective glucose biosensor has attracted extensive attention worldwide. Fluorescence- based strategies have sparked tremendous interest due to their rapid response, facile operation, and excellent sensitivity. Many fluorescent compounds have been employed for precise analysis of glucose, including quantum dots, noble metal nanoclusters, up-converting nanoparticles, organic dyes, and composite fluorescent microspheres. Silicon dot as promising quantum dots materials have received extensive attention, owing to their distinct advantages such as biocompatibility, low toxicity and high photostability. Methods: MnO2 nanosheets on the Si nanoparticles (NPs) surface serve as a quencher. Si NPs fluorescence can make a recovery by the addition of H2O2, which can reduce MnO2 to Mn2+, and the glucose can thus be monitored based on the enzymatic conversion of glucose by glucose oxidase to generate H2O2. Therefore, the glucose concentration can be derived by recording the fluorescence recovery spectra of the Si NPs. Results: This probe enabled selective detection of glucose with a linear range of 1-100 μg/mL and a limit of detection of 0.98 μg/mL. Compared with the commercial glucometer, this method showed favorable results and convincing reliability. Conclusion: We have developed a novel method based on MnO2 -nanosheet-modified Si NPs for rapid monitoring of blood glucose levels. By combining the highly sensitive H2O2/MnO2 reaction with the excellent photostability of Si NPs, a highly sensitive, selective, and cost-efficient sensing approach for glucose detection has been designed and applied to monitor glucose levels in human serum with satisfactory results.


The Analyst ◽  
2021 ◽  
Vol 146 (20) ◽  
pp. 6297-6305
Author(s):  
Qinglan Miao ◽  
Ji Qi ◽  
Yuanyuan Li ◽  
Xinxia Fan ◽  
Dongmei Deng ◽  
...  

A novel paper-based chip that anchored zinc-doped carbon dots was constructed for sensitive and stable fluorescent detection of Cu2+. Zn doping increased the active sites for simplifying the modification of carbon dots.


Sign in / Sign up

Export Citation Format

Share Document