scholarly journals Assessment of the loaded state of the piston unit cylinder stage taking into account of temperature exposure

2019 ◽  
Vol 1260 (11) ◽  
pp. 112002
Author(s):  
I P Aistov ◽  
K A Vansovich
Author(s):  
Chien-Cheng Jung ◽  
Nai-Tzu Chen ◽  
Ying-Fang Hsia ◽  
Nai-Yun Hsu ◽  
Huey-Jen Su

Previous studies have demonstrated that outdoor temperature exposure was an important risk factor for respiratory diseases. However, no study investigates the effect of indoor temperature exposure on respiratory diseases and further assesses cumulative effect. The objective of this study is to study the cumulative effect of indoor temperature exposure on emergency department visits due to infectious (IRD) and non-infectious (NIRD) respiratory diseases among older adults. Subjects were collected from the Longitudinal Health Insurance Database in Taiwan. The cumulative degree hours (CDHs) was used to assess the cumulative effect of indoor temperature exposure. A distributed lag nonlinear model with quasi-Poisson function was used to analyze the association between CDHs and emergency department visits due to IRD and NIRD. For IRD, there was a significant risk at 27, 28, 29, 30, and 31 °C when the CDHs exceeded 69, 40, 14, 5, and 1 during the cooling season (May to October), respectively, and at 19, 20, 21, 22, and 23 °C when the CDHs exceeded 8, 1, 1, 35, and 62 during the heating season (November to April), respectively. For NIRD, there was a significant risk at 19, 20, 21, 22, and 23 °C when the CDHs exceeded 1, 1, 16, 36, and 52 during the heating season, respectively; the CDHs at 1 was only associated with the NIRD at 31 °C during the cooling season. Our data also indicated that the CDHs was lower among men than women. We conclude that the cumulative effects of indoor temperature exposure should be considered to reduce IRD risk in both cooling and heating seasons and NIRD risk in heating season and the cumulative effect on different gender.


Micromachines ◽  
2021 ◽  
Vol 12 (6) ◽  
pp. 643
Author(s):  
Xuhang Zhou ◽  
Qiulin Tan ◽  
Xiaorui Liang ◽  
Baimao Lin ◽  
Tao Guo ◽  
...  

Performing high-temperature measurements on the rotating parts of aero-engine systems requires wireless passive sensors. Surface acoustic wave (SAW) sensors can measure high temperatures wirelessly, making them ideal for extreme situations where wired sensors are not applicable. This study reports a new SAW temperature sensor based on a langasite (LGS) substrate that can perform measurements in environments with temperatures as high as 1300 °C. The Pt electrode and LGS substrate were protected by an AlN passivation layer deposited via a pulsed laser, thereby improving the crystallization quality of the Pt film, with the function and stability of the SAW device guaranteed at 1100 °C. The linear relationship between the resonant frequency and temperature is verified by various high-temperature radio-frequency (RF) tests. Changes in sample microstructure before and after high-temperature exposure are analyzed using scanning electron microscopy (SEM) and X-ray diffraction (XRD). The analysis confirms that the proposed AlN/Pt/Cr thin-film electrode has great application potential in high-temperature SAW sensors.


Author(s):  
Roberto Alers-Velazquez ◽  
Sushant Khandekar ◽  
Clare Muller ◽  
Jennifer Boldt ◽  
Scott Leisner

AbstractLower temperatures delayed development of systemic symptoms by Cauliflower mosaic virus (CaMV) in two different plant hosts. However, lower temperature exposure increased CaMV nucleic acid levels in leaves of systemically-infected turnips. Furthermore, lower temperature altered the formation of aggregates formed by the CaMV major inclusion body (IB) protein, P6. Finally, lower temperature altered the architecture of the actin cytoskeleton. These data may suggest that lower temperatures alter the actin cytoskeleton, facilitating the formation of larger IBs that hold on to their internal virions more strongly than small ones, impairing virus particle release and causing a delay in systemic infection.


1989 ◽  
Vol 170 ◽  
Author(s):  
Håkan A. Swan ◽  
Colette O'meara

AbstractPreliminary creep tests were performed on SiC whisker reinforced and matrix Si3N4 material fabricated by the NPS technique. The material was extensively crystallised in the as received material, leaving only thin amorphous films surrounding the grains. No improvement in the creep resistance could be detected for the whisker reinforced material. The deformation mechanisms were found to be that of cavitation in the form of microcracks, predominantly at the whisker/matrix interfaces, and the formation of larger cracks. Extensive oxidation of the samples, as a result of high temperature exposure to air, was observed for the materials tested at 1375°C.


Sign in / Sign up

Export Citation Format

Share Document