scholarly journals Research and Design on the DMA Monitoring System Based on Low-power Consumption

2020 ◽  
Vol 1654 ◽  
pp. 012081
Author(s):  
FU Ren-xuan ◽  
Xue-Liang
2012 ◽  
Vol 182-183 ◽  
pp. 427-430
Author(s):  
Li Feng Wei ◽  
Liang Cheng ◽  
Xing Man Yang

A adaptive control method of the pulse demagnetizer was presented, Can adjust the strength of the charge current automatically according to the changes of the magnetic content to ensure the constant of the magnetic field.The experimental results have shown that it has the advantages of low power consumption, strong anti-interference capability, stable and reliable operation, long life and good demagnetizing effect, when compared to the conventional demagnetizers.


2013 ◽  
Vol 753-755 ◽  
pp. 2369-2373
Author(s):  
Yu Xuan Hu ◽  
Yi Hu ◽  
Shu Ming Ye ◽  
Xiao Xiang Zheng

As a major indicator of Obstructive Sleep Apnea Syndrome (OSAS) in clinical diagnosis, the monitoring of sleep apnea plays an important role in medical treatments of modern society. This paper proposes a portable sleep apnea monitoring system, which is of high-precision and low-power consumption, and capable of performing the long-term monitoring of OSAS patients multiple physiological parameters in clinical treatments. In the system, the AC modulated detection is adopted, and low amplification ratios are utilized in forestage and a high-resolution AD converter is designed in post-stages. Thus, it is able to acquire, analyze, and process physiological signals in real-time. In addition, ultralow-power chips are used in control system to save the power consumption. The experimental results show that our monitoring system has the strengths of high stability, low-power consumption (peak current90mA), and strong anti-interference ability, which demonstrates the potential in practical applications.


2014 ◽  
Vol 556-562 ◽  
pp. 2577-2580
Author(s):  
Xin You Li ◽  
Ze Bin Xu ◽  
Jin Xu Guo

Along with an increasingly wide utilization in the fields of ETC application, it becomes more and more important to measuring quickly and accurately on the key equipment of ETC system, such as OBU and RSU. This article is based on the measuring requirement of ETC system and propose a new design proposal by selecting STR715FR0 chip base on the core of ARM7TDMI series and 5.8GHz radio frequency transceiver circuit, the actual operation and test results show that the DSRC device Measuring Instrument works with stability, reliability and low power consumption, which enables convenient and efficient measuring to ensure the reliability and consistency of the ETC key equipment.


2019 ◽  
Vol 8 (2) ◽  
pp. 32 ◽  
Author(s):  
Ali Al-Naji ◽  
Ali J. Al-Askery ◽  
Sadik Kamel Gharghan ◽  
Javaan Chahl

Continuous monitoring of breathing activity plays a major role in detecting and classifying a breathing abnormality. This work aims to facilitate detection of abnormal breathing syndromes, including tachypnea, bradypnea, central apnea, and irregular breathing by tracking of thorax movement resulting from respiratory rhythms based on ultrasonic radar detection. This paper proposes a non-contact, non-invasive, low cost, low power consumption, portable, and precise system for simultaneous monitoring of normal and abnormal breathing activity in real-time using an ultrasonic PING sensor and microcontroller PIC18F452. Moreover, the obtained abnormal breathing syndrome is reported to the concerned physician’s mobile telephone through a global system for mobile communication (GSM) modem to handle the case depending on the patient’s emergency condition. In addition, the power consumption of the proposed monitoring system is reduced via a duty cycle using an energy-efficient sleep/wake scheme. Experiments were conducted on 12 participants without any physical contact at different distances of 0.5, 1, 2, and 3 m and the breathing rates measured with the proposed system were then compared with those measured by a piezo respiratory belt transducer. The experimental results illustrate the feasibility of the proposed system to extract breathing rate and detect the related abnormal breathing syndromes with a high degree of agreement, strong correlation coefficient, and low error ratio. The results also showed that the total current consumption of the proposed monitoring system based on the sleep/wake scheme was 6.936 mA compared to 321.75 mA when the traditional operation was used instead. Consequently, this led to a 97.8% of power savings and extended the battery life time from 8 h to approximately 370 h. The proposed monitoring system could be used in both clinical and home settings.


Sign in / Sign up

Export Citation Format

Share Document