scholarly journals New flowing system in cooling system axial-flow pump in a hard coal electric power plant

2021 ◽  
Vol 1741 ◽  
pp. 012006
Author(s):  
G Peczkis ◽  
T Synowiec ◽  
A Zahorulko
1976 ◽  
Vol 98 (3) ◽  
pp. 365-368
Author(s):  
J. A. MacFarlane ◽  
G. Maples ◽  
D. F. Dyer

This paper describes the application of a heat dissipation technique called “phased-cooling” to the cooling of “once-through” river water used in an electric power plant. A thermodynamic model for the situation is developed and the equations applying to the model are given. The performance of the system is analyzed for a summer day in the Southeastern United States. Results of the analysis show that an economically attractive system can be built with less than half of the evaporation loss of cooling towers. This system can meet federal standards.


1906 ◽  
Vol 62 (1608supp) ◽  
pp. 25758-25758
Author(s):  
Alfred Gradenwitz

2021 ◽  
Vol 11 (15) ◽  
pp. 6774
Author(s):  
Fan Yang ◽  
Dongjin Jiang ◽  
Tieli Wang ◽  
Pengcheng Chang ◽  
Chao Liu ◽  
...  

The outlet conduit is an important construction connecting the outlet of the pump guide vane and the outlet pool; in order to study the hydraulic performance of the straight outlet conduit of the axial-flow pump device, this paper adopts the method of numerical simulation and analyzes the influence of the division pier on the pressure and velocity distribution inside and near the wall of the straight outlet conduit based on three design schemes. Four pressure pulsation measuring points were arranged in the straight outlet conduit, and the low-frequency pulsation characteristic information inside the straight outlet conduit with and without the division pier was extracted by wavelet packet reconstruction. The results show that the addition of a division pier has an effect on the hydraulic loss, near-wall pressure and velocity distribution in the straight outlet conduit. A small high-pressure zone is formed near the wall at the starting position of the division pier, and a large high-speed zone is formed on the left side at the starting position of the division pier. The length of the division pier has no significant effect on the flow distribution of the straight outlet conduit and the pressure and velocity distribution near the wall. Under different working conditions, each monitoring point has the maximum energy in the sub-band (0~31.25 Hz). With the increase of the flow rate, the total pressure energy of the straight outlet conduit decreases gradually. Under each condition, the difference of the energy proportion of the horizontal monitoring points of the straight outlet conduit is small, and the difference of the energy proportion of the two monitoring points at the top and bottom of the outlet channel is relatively large. The energy of the two monitoring points in the straight outlet conduit with a division pier is smaller than that of the two monitoring points in the straight outlet conduit without a division pier. There are differences in the main frequency and the power spectrum corresponding to the main frequency of the monitoring points in the straight outlet conduit, and the reasonable setting of the division pier is conducive to reducing the pressure pulsation of the flow in the straight outlet conduit and is beneficial to the safe and stable operation of the pump device.


Sign in / Sign up

Export Citation Format

Share Document