outlet conduit
Recently Published Documents


TOTAL DOCUMENTS

8
(FIVE YEARS 3)

H-INDEX

1
(FIVE YEARS 0)

2021 ◽  
Vol 11 (15) ◽  
pp. 6774
Author(s):  
Fan Yang ◽  
Dongjin Jiang ◽  
Tieli Wang ◽  
Pengcheng Chang ◽  
Chao Liu ◽  
...  

The outlet conduit is an important construction connecting the outlet of the pump guide vane and the outlet pool; in order to study the hydraulic performance of the straight outlet conduit of the axial-flow pump device, this paper adopts the method of numerical simulation and analyzes the influence of the division pier on the pressure and velocity distribution inside and near the wall of the straight outlet conduit based on three design schemes. Four pressure pulsation measuring points were arranged in the straight outlet conduit, and the low-frequency pulsation characteristic information inside the straight outlet conduit with and without the division pier was extracted by wavelet packet reconstruction. The results show that the addition of a division pier has an effect on the hydraulic loss, near-wall pressure and velocity distribution in the straight outlet conduit. A small high-pressure zone is formed near the wall at the starting position of the division pier, and a large high-speed zone is formed on the left side at the starting position of the division pier. The length of the division pier has no significant effect on the flow distribution of the straight outlet conduit and the pressure and velocity distribution near the wall. Under different working conditions, each monitoring point has the maximum energy in the sub-band (0~31.25 Hz). With the increase of the flow rate, the total pressure energy of the straight outlet conduit decreases gradually. Under each condition, the difference of the energy proportion of the horizontal monitoring points of the straight outlet conduit is small, and the difference of the energy proportion of the two monitoring points at the top and bottom of the outlet channel is relatively large. The energy of the two monitoring points in the straight outlet conduit with a division pier is smaller than that of the two monitoring points in the straight outlet conduit without a division pier. There are differences in the main frequency and the power spectrum corresponding to the main frequency of the monitoring points in the straight outlet conduit, and the reasonable setting of the division pier is conducive to reducing the pressure pulsation of the flow in the straight outlet conduit and is beneficial to the safe and stable operation of the pump device.


2021 ◽  
Vol 11 (11) ◽  
pp. 4941
Author(s):  
Fan Yang ◽  
Yiqi Zhang ◽  
Yao Yuan ◽  
Chao Liu ◽  
Zhongbin Li ◽  
...  

In order to study the variation law of the flow field and pressure fluctuation in the hump section of the siphon outlet conduit, the flow field characteristics and frequency spectrum characteristics of the flow field were analyzed by combining a physical model test and numerical simulation under the conditions of the interaction between the axial flow pump and siphon outlet conduit, and the influence of the residual circulation at the outlet of the guide vane on the siphon outlet flow was investigated. Based on the influence of the flow field and hydraulic loss in the conduit, the equivalent surface method based on the Q criterion was used to analyze the vortex structure in the siphon outlet conduit and to analyze the internal vortex state. The results showed that with the increase of the flow rate, the intensity of the vortices in the cross-section of the hump section of the siphon outlet conduit decreased gradually, the average velocity circulation decreased gradually and the axial velocity distribution uniformity increased and tended to be stable; water flow stratification existed under three characteristic conditions with no circulation, and the hydraulic loss was greater with the circulation flow while it had a circulation under the small flow condition. Under the low flow rate conditions, the hydraulic loss was 6.6 times higher under the condition of circulation than without. Under a high flow condition, it was 1.3 times. Under the condition of a small flow rate, the vortex structure was distributed centrally at the inlet of the flow conduit, and under the other two characteristic conditions, the vortex structure mostly appeared as a strip; the pressure fluctuation in the hump section had obvious periodicity, and with the increase of the flow rate, the maximum pressure fluctuation amplitude in the hump section decreased gradually; with the decrease of the rotational speed, the pressure amplitude at the same measuring point in the hump section decreased gradually and at the optimum condition. Under the following conditions, the mean value of the pressure amplitude at the top of the hump section was reduced by 69.63%, and the mean value of the pressure amplitude at the bottom of the hump section was reduced by 63.5%. Under all the calculation conditions, the main frequency of pulsation at each measuring point of the hump section was twice the frequency of the rotation.


2017 ◽  
Vol 21 (3) ◽  
pp. 61-68
Author(s):  
Marian Panasiewicz ◽  
Jacek Mazur ◽  
Rafał Nadulski ◽  
Paweł Sobczak ◽  
Kazimierz Zawiślak ◽  
...  

AbstractThe objective of the paper was to determine the impact of the value of the oil pressing pressure with the cold pressing method in a screw press on the pressing course and performance. Varied values of pressure were obtained through the use of three replaceable attachments of the pressing unit with a varied diameter of the outlet conduit (ф1=2 mm, ф2=4 mm and ф3=6 mm). The soya oil pressing process performance was determined in relation to the applied attachment and the soya cultivar. Seeds of 7 Polish non-genetically modified soya cultivars constituted research material. It was proved that both variable pressure values and the used soya cultivars have impact on the pressing performance. Based on the analysis of the obtained research results it was proved that varied technical parameters and soya cultivars influence both the process performance and the remaining parameters and pressing conditions.


H2GEO ◽  
2004 ◽  
Author(s):  
Joseph A. Cesare ◽  
Daniel J. Brauer

2001 ◽  
Vol 2 (1) ◽  
pp. 19-22 ◽  
Author(s):  
Mihai Croitoru ◽  
Raymond Stainback ◽  
O H Frazier ◽  
Branislav Radovancevic ◽  
Timothy Myers ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document