scholarly journals Adaptive Threshold Scheme for Pulse Detection under Condition of Background Nonstationary Noise

2021 ◽  
Vol 2096 (1) ◽  
pp. 012019
Author(s):  
A O Shcherbina ◽  
O O Lukovenkova ◽  
A A Solodchuk

Abstract The paper describes a new adaptive threshold scheme for detecting pulses in high-frequency signals against a background of non-stationary noise. The result of the scheme operation is to determine the pulse boundaries by comparing the signal amplitude-time parameters with the threshold. The threshold value is calculated in non-overlapping windows of fixed length and depends only on the background noise level. The detected pulses undergo additional shape checking, taking into account their characteristics. The parameters of the algorithms for detecting pulses and checking their shape can be adjusted for any type of high-frequency pulse signals. This threshold scheme is tuned to detect pulses in high frequency geoacoustic emission signals. The results of the scheme operation on an artificial signal and on fragments of a geoacoustic signal are given, a comparison is made between the proposed scheme and the previously used (outdated) one. The new threshold scheme proposed by the authors is less sensitive to the choice of the initial threshold value and it is more stable in operation. When processing 15-minute fragments of a geoacoustic signal, the new scheme correctly detects, on average, 5 times more pulses.

Author(s):  
Y Liu ◽  
Y Qu ◽  
W Zhang ◽  
F Ma ◽  
Z Sha ◽  
...  

1990 ◽  
Vol 38 (4) ◽  
pp. 1019-1021 ◽  
Author(s):  
Tamotsu KOIZUMI ◽  
Masawa KAKEMI ◽  
Kazunori KATAYAMA ◽  
Hirohiko INADA ◽  
Kazuyoshi SUDEJI ◽  
...  

Sensors ◽  
2017 ◽  
Vol 17 (4) ◽  
pp. 764 ◽  
Author(s):  
Hojong Choi ◽  
Park Woo ◽  
Jung-Yeol Yeom ◽  
Changhan Yoon

Author(s):  
A. Ibrahim ◽  
C.C. Berndt

Abstract The effect of high frequency pulse detonation (HFPD) and HVOF thermally sprayed WC-Co coatings on the high cycle fatigue (HCF) behavior of 2024-T4 aluminum was investigated. The fatigue life distributions of specimens in the polished and coated conditions are presented as a function of the probability of failure. The monotonic and cyclic deformation behaviors of the as-received and as-coated specimens were investigated. The conclusions show that, (i) the HFPD sprayed specimens exhibited slightly higher fatigue lives compared to the uncoated specimens, (ii) the HVOF sprayed specimens exhibited significantly higher fatigue lives compared to the uncoated specimens, and (iii) the as-coated specimen was cyclically stable.



1979 ◽  
Vol 63 (5) ◽  
pp. 753
Author(s):  
Zygmunt Kratochwil ◽  
A Duma-Drzewinska ◽  
A Buczynski

Sign in / Sign up

Export Citation Format

Share Document