scholarly journals Analysis of Seismic Isolation Effect of Rubber Bearings with Different Periods of Isolated Structures

Author(s):  
Shuiqiang Qin ◽  
Xiaosheng Song ◽  
Shuo Wang ◽  
Dandan Du
2010 ◽  
Vol 59 (1) ◽  
pp. 20-25
Author(s):  
Takashi KANEKO ◽  
Masayuki HYODO ◽  
Yukio NAKATA ◽  
Norimasa YOSHIMOTO ◽  
Hemanta HAZARIKA

2011 ◽  
Vol 255-260 ◽  
pp. 1225-1229
Author(s):  
Huang Sheng Sun ◽  
Li Nuo Cheng ◽  
Shi Hai Chen

In order to mitigate the seismic response of twin-tower structure linked by a steel truss platform bridge, as well as to reduce temperature force in the steel truss, eight groups of combined isolation system, each consisting of one pot-type bearing and four rubber bearings, were designed to connect the upper platform bridge to the lower supporting reinforced concrete towers. The features and working principles of the high-position isolation system were described. Then the seismic responses, including displacement, story drift and floor acceleration, of the structure with the isolation systems were calculated and compared with those of the structure with hinge joints in lieu of isolation. It is found that both the structural seismic responses and the temperature forces in the large-span mega-truss structure can be reduced by the high-position isolation system.


1999 ◽  
pp. 27-36
Author(s):  
Sadao SHIMAMURA ◽  
Hiroshi KASAI ◽  
Masakazu HARUUMI

Author(s):  
Keisuke Minagawa ◽  
Satoshi Fujita

Since the Hanshin-Awaji Earthquake Disaster, the number of isolated structures has been greatly increased. The natural period of the isolation system is designed around 3 seconds, because predominate period of observed seismic waves is usually 0.1 to 1 second. However, relatively long period seismic waves have been observed in various earthquakes, and the resonance of long-period structures, such as high-rise buildings, during earthquakes have been reported at the same time. Therefore the natural period needs to be extended. When extending the natural period of the isolated structure using rubber bearings, its stiffness needs to be reduced. It is more difficult to extend the natural period of the isolation system than the conventional system because of its buckling problem. Therefore we propose a super-long-period active seismic isolation system as a new method for extending the natural period of the isolated structure. This system consists of rubber bearings and actuators. In this study, we designed a control system by using the model-matching-method. This is one of the classical control system design methods. We investigated the isolation performance by numerical analysis. In addition, we selected the optimal variables of transfer function using genetic algorithm.


Author(s):  
Satoru Inaba ◽  
Takuya Anabuki ◽  
Kazutaka Shirai ◽  
Shuichi Yabana ◽  
Seiji Kitamura

This paper describes the dynamic damage test of a reinforced concrete (RC) wall structure with seismic isolation sysytem. It has been expected that seismically isolated structures are damaged in sudden when the accelerations of the structures exceed a certain level by hardening of the rubber bearings. However, the response behavior and the damage mode have not been observed by experimental test yet. So, shaking table tests were carried out at “E-Defense”, equipping the world’s largest shaking table, located at Miki City, Hyogo prefecture, Japan. The specimen was composed of an upper structure of 600 ton by weight and six lead-rubber bearings (LRBs) of 505 mm in diameter which provide both stiffness and hysteretic damping. The upper structure consisted of a RC mass and four RC walls with counter weight. The RC wall structure was designed so that the damage of the RC wall occurred between the shear force at the hardening of the rubber bearings and that at their breaking. The dimensions of the RC wall were 1600 × 800 × 100 mm (B × H × t). The reinforcement ratios were 2.46% in vertical by D13 (deformed reinforcing bar, 13 mm in diameter) and 1.0% in horizontal by D10. The shaking table test was conducted consecutively by increasing the levels up to 225% of tentative design earthquake motion. Consequently, because of the increase of the structural response by the hardening of the rubber bearings, the damage of the wall structure with seismic isolation system suddenly happened. In addition, the preliminary finite element analysis simulated the test results fairly well, which were the restoring force characteristics, the crack patterns of the RC wall structure and such.


Author(s):  
Alexandre Borsoi ◽  
Satoshi Fujita ◽  
Keisuke Minagawa

In Japan, the application of seismic isolation systems using rubber bearings to industrial structure and new generation Nuclear Power Plants have been considered in order to enhance seismic safety. However, the isolation performance will decline in case of huge earthquakes, because of the nonlinearity of both horizontal and vertical restoring characteristics of the rubber bearings. The horizontal restoring force has a hardening characteristic and the vertical restoring force has a softening characteristic. In addition, the horizontal nonlinearity depends on vertical load, so the interaction between the horizontal and vertical response is important. Consequently, in this paper, the analysis of the nonlinearity of the rubber bearings and the coupling between those two directions will be carried out. Then, after comparing these two approaches, the utility of considering this dependency will be estimated. To do so, a simulation program, based on the Runge-Kutta-Gill’s method has been developed in order to evaluate the seismic response of the isolated structure composed of rubber bearings and oil dampers. The nonlinearity of the rubber bearings is considered, and the coupling of the vertical load and the horizontal hardening has been implemented.


Sign in / Sign up

Export Citation Format

Share Document