scholarly journals Impact of high volume GGBS replacement and steel bar length on flexural behaviour of reinforced concrete beams

2021 ◽  
Vol 1090 (1) ◽  
pp. 012015
Author(s):  
Zainab S. Al-Khafaji ◽  
Ali Majdi ◽  
Ali A. Shubbar ◽  
Mohammed Salah Nasr ◽  
Shahad F. Al-Mamoori ◽  
...  
2020 ◽  
Vol 241 ◽  
pp. 112059 ◽  
Author(s):  
Cristina Barris ◽  
Pau Sala ◽  
Javier Gómez ◽  
Lluís Torres

Materials ◽  
2020 ◽  
Vol 13 (1) ◽  
pp. 234 ◽  
Author(s):  
Yingwu Zhou ◽  
Yaowei Zheng ◽  
Lili Sui ◽  
Biao Hu ◽  
Xiaoxu Huang

Steel corrosion is considered as the main factor for the insufficient durability of concrete structures, especially in the marine environment. In this paper, to further inhibit steel corrosion in a high chloride environment and take advantage of the dual-functional carbon fiber reinforced polymer (CFRP), the impressed current cathodic protection (ICCP) technique was applied to the hybrid-reinforced concrete beam with internally embedded CFRP bars and steel fiber reinforced polymer composite bar (SFCB) as the anode material while the steel bar was compelled to the cathode. The effect of the new ICCP system on the flexural performance of the hybrid-reinforced concrete beam subjected to corrosion was verified experimentally. First, the electricity-accelerated precorrosion test was performed for the steel bar in the hybrid-reinforced beams with a target corrosion ratio of 5%. Then, the dry–wet cycles corrosion was conducted and the ICCP system was activated simultaneously for the hybrid-reinforced concrete beam for 180 days. Finally, the three-point bending experiment was carried out for the hybrid-reinforced concrete beams. The steel bars were taken out from the concrete to quantitatively measure the corrosion ratio after flexural tests. Results showed that the further corrosion of steel bars could be inhibited effectively by the ICCP treatment with the CFRP bar and the SFCB as the anode. Additionally, the ICCP system showed an obvious effect on the flexural behavior of the hybrid-reinforced concrete beams: The crack load and ultimate load, as well as the stiffness, were enhanced notably compared with the beam without ICCP treatment. Compared with the SFCB anode, the ICCP system with the CFRP bar as the anode material was more effective for the hybrid-reinforced concrete beam to prevent the steel corrosion.


2019 ◽  
Vol 27 (1) ◽  
pp. 247-261
Author(s):  
Abass Oda Dawood ◽  
Hamsa Mahir Adnan

This research is aimed to study the possibility of recycled the PET wastes by forming the PET wastes as plastic semi-bars and used it as tension bars in simply supported reinforced concrete beams . Twelve beams specimens with dimension of (150*200*1400) mm are casted and tested to monitoring the effecting of these wastes as tension bars on the strengths and serviceability of reinforced concrete beams. The mechanical properties (compressive, splitting tensile and flexural strength) are evaluated in which specimens tested in age of 28 days. The tests results showed that all presented plastic semi-bars are failed except one case in which the deformed steel bar are used with additional layer of PET bottle cut into two parts which showed an increment in ultimate failure load and deflection of  3.03 % and 213.83 % respectively, larger than the reference beam specimens. Negatively effect of PET semi-bar on ultimate load of beams is due to bonding failure between PET bars and surrounding concrete, which made the PET bars as voids or weak region within beam cross section.


Sign in / Sign up

Export Citation Format

Share Document