A Cross-Sectional Pilot Survey of Rural Clinic Attitudes and Proficiency with Insulin Pumps and Continuous Glucose Monitoring Devices

2019 ◽  
Vol 21 (11) ◽  
pp. 665-670
Author(s):  
Andrew Bergloff ◽  
Emily Stratton ◽  
Kathaleen Briggs Early
2019 ◽  
Vol 11 (1) ◽  
pp. 255-255 ◽  
Author(s):  
Yushi Hirota ◽  
Masao Toyoda ◽  
Takashi Murata ◽  
Junnosuke Miura

2020 ◽  
Vol 4 (6) ◽  
pp. 352-357
Author(s):  
F.O. Ushanova ◽  
◽  
T.Yu. Demidova ◽  

Currently, the management of pregnant women with carbohydrate metabolism disorders is challenging due to the high risk of unfavorable events both for the mother and the child even in insignificant deviations from the target value. In addition to the conventional methods of self-monitoring, continuous glucose monitoring (CGM) is an important tool to control diabetes. CGM in pregnant women provides the detailed information on the type and trends of the changes in blood glucose levels and the fluctuations of glucose levels and also identifies the episodes of latent nocturnal hypoglycemia and postprandial hyperglycemia. The analysis of CGM data allows for correcting insulin therapy, taking a decision on its initiation, and modifying diet and exercise plan. Multiple studies demonstrate the efficacy of CGM in terms of compensating manifest diabetes. As to gestational diabetes, the eligibility of modern glucose monitoring technologies for the prevention of various complications is still controversial. Further studies on the potential use of these devices in gestational diabetes could provide a basis for increasing their application in routine clinical practice. This will improve the management of pregnant women with carbohydrate metabolism disorders.KEYWORDS: diabetes, gestational diabetes, continuous glucose monitoring, flash monitoring, pregnancy, macrosomia, self-monitoring.FOR CITATION: Ushanova F.O., Demidova T.Yu. Potentialities of modern glucose monitoring devices during pregnancy. Russian Medical Inquiry. 2020;4(6):352–357. DOI: 10.32364/2587-6821-2020-4-6-352-357.


2019 ◽  
Vol 14 (1) ◽  
pp. 83-86 ◽  
Author(s):  
Sarah Puhr ◽  
Mark Derdzinski ◽  
Andrew Scott Parker ◽  
John B. Welsh ◽  
David A. Price

Background: Frequent real-time continuous glucose monitoring (rtCGM) data viewing has been associated with reduced mean glucose and frequent scanning of an intermittently scanned continuous glucose monitoring (isCGM) system has been associated with reduced hypoglycemia for patients with diabetes. However, requiring patients to frequently interact with their glucose monitoring devices to detect actual or impending hypoglycemia is burdensome. We hypothesized that a predictive low glucose alert, which forecasts glucose ≤55 mg/dL within 20 minutes and is included in a new rtCGM system, could mitigate hypoglycemia without requiring frequent device interaction. Methods: We analyzed estimated glucose values (EGVs) from an anonymized convenience sample of 15,000 patients who used Dexcom G6 (Dexcom, Inc, San Diego, CA, USA) and its mobile app for at least 30 days with or without the “Urgent Low Soon” alert (ULS) enabled. Screen view frequency was determined as the frequency with which the trend screen was accessed on the app. Multiple screen views within any 5-minute interval were counted as one. Hypoglycemia exposure for patients in the top and bottom quartiles of screen view frequency (>8.25 and <3.30 per day, respectively) was calculated as the percentage of EGVs below various thresholds. Results: Over 93% of users enabled the ULS alert; its use was associated with significantly reduced hypoglycemia <55 and <70 mg/dL, independent of screen view frequency. Conclusion: Use of the G6 ULS alert may disencumber rtCGM users by promoting significant reductions in hypoglycemia without requiring frequent device interactions.


Sign in / Sign up

Export Citation Format

Share Document