Latent class analysis for the diagnosis of Clostridioides difficile infection

Author(s):  
Cody P Doolan ◽  
Thomas Louie ◽  
Christopher Lata ◽  
Oscar E Larios ◽  
William Stokes ◽  
...  

Abstract Background Clostridioides difficile infection (CDI) is an opportunistic disease that lacks a gold standard test. Nucleic acid amplification tests (NAATs) such as real-time PCR demonstrate excellent an limit of detection (LOD) whereas antigenic methods are able to detect free toxin. Latent class analysis (LCA) provides an unbiased statistical approach to resolving true disease. Methods A cross-sectional study was conducted with suspected CDI patients (n=96). Four commercial real-time PCR tests, toxin antigen detection by enzyme immunoassay (EIA), toxigenic culture, and fecal calprotectin were performed. CDI clinical diagnosis was determined by consensus majority of three experts. LCA was performed using laboratory and clinical variables independent of any gold standard. Results Six LCA models were generated to determine CDI probability using four variables including toxin EIA, toxigenic culture, clinical diagnosis, and fecal calprotectin levels. Three defined zones as a function of real-time PCR cycle threshold (Ct) were identified using LCA: CDI likely (>90% probability), equivocal (<90% and >10%), CDI unlikely (<10%). A single model comprising toxigenic culture, clinical diagnosis, and toxin EIA showed the best fitness. The following Ct cut-offs for four commercial test platforms were obtained using this model to delineate three CDI probability zones: [GeneXpert ® : 24.00, 33.61], [Simplexa ® 28.97, 36.85], [Elite MGB ® 30.18, 37.43], and [BD Max ™ 27.60, 34.26]. Conclusion The clinical implication of applying LCA to CDI is to report Ct values assigned to probability zones based on the commercial real-time PCR platform. A broad range of equivocation suggests clinical judgement is essential to the confirmation of CDI.

2020 ◽  
Vol 10 (4) ◽  
pp. 210-216
Author(s):  
Konstantin Tanida ◽  
Andreas Hahn ◽  
Hagen Frickmann

AbstractIntroductionThe aim of the study was a comparative evaluation of in-house real-time PCR and commercial real-time PCR (Fast Track Diagnostics (FTD), ampliCube/Mikrogen) targeting enteropathogenic bacteria from stool in preparation of Regulation (EU) 2017/746 on in vitro diagnostic medical devices.MethodsBoth 241 stool samples from patients and 100 samples from German laboratory control schemes (“Ringversuche”) were used to comparatively assess in-house real-time PCR, the FTD bacterial gastroenteritis kit, and the ampliCube gastrointestinal bacterial panels 1&2 either with the in-house PCRs as gold standard and as a test comparison without gold standard applying latent class analysis. Sensitivity, specificity, intra- and inter-assay variation and Cohen’s kappa were assessed.ResultsIn comparison with the gold standard, sensitivity was 75–100% for strongly positive samples, 20–100% for weakly positive samples, and specificity ranged from 96 to 100%. Latent class analysis suggested that sensitivity ranges from 81.2 to 100% and specificity from 58.5 to 100%. Cohen’s kappa varied between moderate and nearly perfect agreement, intra- and inter-assay variation was 1–3 to 1–4 Ct values.ConclusionAcceptable agreement and performance characteristics suggested replaceability of the in-house PCR assays by the commercial approaches.


2021 ◽  
Vol 10 (11) ◽  
pp. 2404
Author(s):  
Sascha Dierks ◽  
Oliver Bader ◽  
Julian Schwanbeck ◽  
Uwe Groß ◽  
Michael Weig ◽  
...  

This study was performed as a head-to-head comparison of the performance characteristics of (1) two SARS-CoV-2-specific rapid antigen assays with real-time PCR as gold standard as well as (2) a fully automated high-throughput transcription-mediated amplification (TMA) assay and real-time PCR in a latent class analysis-based test comparison without a gold standard with several hundred samples in a low prevalence “real world” setting. Recorded sensitivity and specificity of the NADAL and the LumiraDx antigen assays and the Hologic Aptima SARS-CoV-2 TMA assay were 0.1429 (0.0194, 0.5835), 0.7644 (0.7016, 0.8174), and 0.7157 (0, 1) as well as 0.4545 (0.2022, 0.7326), 0.9954 (0.9817, 0.9988), and 0.9997 (not estimable), respectively. Agreement kappa between the positive results of the two antigen-based assays was 0.060 (0.002, 0.167) and 0.659 (0.492, 0.825) for TMA and real-time PCR. Samples with low viral load as indicated by cycle threshold (Ct) values > 30 were generally missed by both antigen assays, while 1:10 pooling suggested higher sensitivity of TMA compared to real-time PCR. In conclusion, both sensitivity and specificity speak in favor of the use of the LumiraDx rather than the NADAL antigen assay, while TMA results are comparably as accurate as PCR, when applied in a low prevalence setting.


Pathogens ◽  
2021 ◽  
Vol 10 (6) ◽  
pp. 656
Author(s):  
Konstantin Tanida ◽  
Andreas Hahn ◽  
Kirsten Alexandra Eberhardt ◽  
Egbert Tannich ◽  
Olfert Landt ◽  
...  

Microsporidiosis is an infection predominantly occurring in immunosuppressed patients and infrequently also in travelers. This study was performed to comparatively evaluate the diagnostic accuracy of real-time PCR assays targeting microsporidia with etiological relevance in the stool of human patients in a latent class analysis-based test comparison without a reference standard with perfect accuracy. Thereby, two one-tube real-time PCR assays and two two-tube real-time PCR assays targeting Enterocytozoon bieneusi and Encephalocytozoon spp. were included in the assessment with reference stool material (20), stool samples from Ghanaian HIV-positive patients (903), and from travelers, migrants and Colombian indigenous people (416). Sensitivity of the assays ranged from 60.4% to 97.4% and specificity from 99.1% to 100% with substantial agreement according to Cohen’s kappa of 79.6%. Microsporidia DNA was detected in the reference material and the stool of the HIV patients but not in the stool of the travelers, migrants, and the Colombian indigenous people. Accuracy-adjusted prevalence was 5.8% (n = 78) for the study population as a whole. In conclusion, reliable detection of enteric disease-associated microsporidia in stool samples by real-time PCR could be demonstrated, but sensitivity between the compared microsporidia-specific real-time PCR assays varied.


2017 ◽  
Vol 381 ◽  
pp. 92-93
Author(s):  
S. Dian ◽  
R. Rahmadi ◽  
C. Ruesen ◽  
L. Chaidir ◽  
J. Annisa ◽  
...  

2012 ◽  
Vol 53 (2) ◽  
pp. 167-170 ◽  
Author(s):  
Jutte J.C. de Vries ◽  
Annemiek A. van der Eijk ◽  
Katja C. Wolthers ◽  
Lisette G. Rusman ◽  
Suzan D. Pas ◽  
...  

2009 ◽  
Vol 50 (1) ◽  
pp. 211-212
Author(s):  
Shi-Ying Xuan ◽  
Yong-Ning Xin ◽  
Yan-Dan Zhong ◽  
Ming-Hua Zheng ◽  
Hua-Shi Guan

2015 ◽  
Vol 119 (4) ◽  
pp. 1158-1169 ◽  
Author(s):  
S. Collins ◽  
F. Jorgensen ◽  
C. Willis ◽  
J. Walker

Sign in / Sign up

Export Citation Format

Share Document