scholarly journals Real-time PCR to supplement gold-standard culture-based detection of Legionella in environmental samples

2015 ◽  
Vol 119 (4) ◽  
pp. 1158-1169 ◽  
Author(s):  
S. Collins ◽  
F. Jorgensen ◽  
C. Willis ◽  
J. Walker
2017 ◽  
Vol 55 (7) ◽  
pp. 2137-2142 ◽  
Author(s):  
Deirdre L. Church ◽  
Heather Baxter ◽  
Tracie Lloyd ◽  
Oscar Larios ◽  
Daniel B. Gregson

ABSTRACTLife-threatening infection in neonates due to group BStreptococcus(GBS) is preventable by screening of near-term pregnant women and treatment at delivery. A total of 295 vaginal-rectal swabs were collected from women attending antepartum clinics in Calgary, Alberta, Canada. GBS colonization was detected by the standard culture method (Strep B Carrot Broth subcultured to blood agar with a neomycin disk) and compared to recovery with Strep Group B Broth (Dalynn Biologicals) subcultured to StrepBSelectchromogenic medium (CM; Bio-Rad Laboratories) and the Fast-Track Diagnostics GBS real-time PCR (quantitative PCR [qPCR]) assay (Phoenix Airmid Biomedical Corp.) performed with broth-enriched samples and the Abbottm2000sp/m2000rt system. A total of 62/295 (21%) women were colonized with GBS; 58 (19.7%) cases were detected by standard culture, while CM and qPCR each found 61 (20.7%) cases. The qPCR and CM were similar in performance, with sensitivities, specificities, and positive and negative predictive values of 98.4 and 98.4%, 99.6 and 99.6%, 98.4 and 98.4%, and 99.6 and 99.6%, respectively, compared to routine culture. Both qPCR and CM would allow more rapid reporting of routine GBS screening results than standard culture. Although the cost per test was similar for standard culture and CM, the routine use of qPCR would cost approximately four times as much as culture-based detection. Laboratories worldwide should consider implementing one of the newer methods for primary GBS testing, depending on the cost limitations of different health care jurisdictions.


2019 ◽  
Author(s):  
Elodie Barbier ◽  
Carla Rodrigues ◽  
Geraldine Depret ◽  
Virginie Passet ◽  
Laurent Gal ◽  
...  

ABSTRACTKlebsiella pneumoniae (Kp) is of growing public health concern due to the emergence of strains that are multidrug-resistant, virulent, or both. Taxonomically, Kp includes seven phylogroups, with Kp1 (K. pneumoniae sensu stricto) being medically prominent. Kp can be present in environmental sources such as soils and vegetation, which could act as reservoirs of animal and human infections. However, the current lack of screening methods to detect Kp in complex matrices limits research on Kp ecology. Here we analysed 4222 genome sequences and found that existing molecular detection targets lack specificity for Kp. A novel real-time PCR method, the ZKIR assay, was developed and used to detect Kp in 96 environmental samples. Results were compared to a culture-based method using SCAI agar medium coupled to MALDI-TOF mass spectrometry identification. Whole-genome sequencing of environmental Kp was performed. The ZKIR assay was positive for the 48 tested Kp reference strains, whereas 88 non-Kp strains were negative. The limit of detection of Kp in spiked soil microcosms was 1.5 × 10-1 CFU g-1 after enrichment for 24 h in LB supplemented with ampicillin, and 1.5 × 103 to 1.5 × 104 CFU g-1 directly after soil DNA extraction. The ZKIR assay was more sensitive than the culture method. Kp was detected in 43% of environmental samples. Genomic analysis of the isolates revealed a predominance of phylogroups Kp1 (65%) and Kp3 (32%), a high genetic diversity (23 MLST sequence types), a quasi-absence of antibiotic resistance or virulence genes, and a high frequency (50%) of O-antigen type 3. This study shows that the ZKIR assay is an accurate, specific and sensitive novel method to detect the presence of Kp in complex matrices, and indicates that Kp isolates from environmental samples differ from clinical isolates.IMPORTANCEThe Klebsiella pneumoniae species complex (Kp) includes human and animal pathogens, some of which are emerging as hypervirulent and/or antibiotic resistant strains. These pathogens are diverse and classified into seven phylogroups, which may differ in their reservoirs and epidemiology. Proper management of this public health hazard requires a better understanding of Kp ecology and routes of transmission to humans. So far, detection of these microorganisms in complex matrices such as food or the environment has been difficult due to a lack of accurate and sensitive methods. Here, we describe a novel method based on real-time PCR, which enables detection of all Kp phylogroups with high sensitivity and specificity. We used this method to detect Kp isolates from environmental samples, and show based on genomic sequencing that they differ in antimicrobial resistance and virulence gene content, from human clinical Kp isolates. The ZKIR PCR assay will enable rapid screening of multiple samples for Kp presence and will thereby facilitate tracking the dispersal patterns of these pathogenic strains across environmental, food, animal and human sources.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Tsui-Kang Hsu ◽  
Jung-Sheng Chen ◽  
Hsin-Chi Tsai ◽  
Chi-Wei Tao ◽  
Yu-Yin Yang ◽  
...  

AbstractAcanthamoeba spp. are opportunistic human pathogens that cause granulomatous amoebic encephalitis and keratitis, and their accurate detection and enumeration in environmental samples is a challenge. In addition, information regarding the genotyping of Acanthamoeba spp. using various PCR methods is equally critical. Therefore, considering the diverse niches of habitats, it is necessary to develop an even more efficient genotyping method for Acanthamoeba spp. detection. This study improved the sensitivity of detection to avoid underestimation of Acanthamoeba spp. occurrence in aquatic environmental samples, and to accurately define the pathogenic risk by developing an efficient PCR method. In this study, a new nested genotyping method was established and compared with various PCR-based methods using in silico, lab, and empirical tests. The in silico test showed that many PCR-based methods could not successfully align specific genotypes of Acanthamoeba, except for the newly designed nested PCR and real-time PCR method. Furthermore, 52 water samples from rivers, reservoirs, and a river basin in Taiwan were analysed by six different PCR methods and compared for genotyping and detection efficiency of Acanthamoeba. The newly developed nested-PCR-based method of genotyping was found to be significantly sensitive as it could effectively detect the occurrence of Acanthamoeba spp., which was underestimated by the JDP-PCR method. Additionally, the present results are consistent with previous studies indicating that the high prevalence of Acanthamoeba in the aquatic environment of Taiwan is attributed to the commonly found T4 genotype. Ultimately, we report the development of a small volume procedure, which is a combination of recent genotyping PCR and conventional real-time PCR for enumeration of aquatic Acanthamoeba and acquirement of biologically meaningful genotyping information. We anticipate that the newly developed detection method will contribute to the precise estimation, evaluation, and reduction of the contamination risk of pathogenic Acanthamoeba spp., which is regularly found in the water resources utilised for domestic purposes.


2006 ◽  
Vol 52 (5) ◽  
pp. 482-488 ◽  
Author(s):  
Rebekka R.E Artz ◽  
Lisa M Avery ◽  
Davey L Jones ◽  
Ken Killham

The detection sensitivity and potential interference factors of a commonly used assay based on real-time polymerase chain reaction (PCR) for Escherichia coli O157:H7 using eae gene-specific primers were assessed. Animal wastes and soil samples were spiked with known replicate quantities of a nontoxigenic strain of E. coli O157:H7 in a viable or dead state and as unprotected DNA. The detection sensitivity and accuracy of real-time PCR for E. coli O157:H7 in animal wastes and soil is low compared to enrichment culturing. Nonviable cells and unprotected DNA were shown to produce positive results in several of the environmental samples tested, leading to potential overestimates of cell numbers due to prolonged detection of nonviable cells. This demonstrates the necessity for the specific calibration of real-time PCR assays in environmental samples. The accuracy of the eae gene–based detection method was further evaluated over time in a soil system against an activity measurement, using the bioluminescent properties of an E. coli O157:H7 Tn5luxCDABE construct. The detection of significant numbers of viable but nonculturable (VBNC) as well as nonviable and possibly physically protected cells as shown over a period of 90 days further complicates the use of real-time PCR assays for quick diagnostics in environmental samples and infers that enrichment culturing is still required for the final verification of samples found positive by real-time PCR methods.Key words: Escherichia coli O157:H7, real-time PCR, animal waste, soil, VBNC.


2012 ◽  
Vol 53 (2) ◽  
pp. 167-170 ◽  
Author(s):  
Jutte J.C. de Vries ◽  
Annemiek A. van der Eijk ◽  
Katja C. Wolthers ◽  
Lisette G. Rusman ◽  
Suzan D. Pas ◽  
...  

2010 ◽  
Vol 56 (9) ◽  
pp. 761-770 ◽  
Author(s):  
Hua Yang ◽  
Oleksandr A. Byelashov ◽  
Ifigenia Geornaras ◽  
Lawrence D. Goodridge ◽  
Kendra K. Nightingale ◽  
...  

This study examined the presence of antibiotic-resistant commensal bacteria among cattle operations representing areas heavily affected by agriculture, city locations representing areas affected by urban activities and indirectly affected by agriculture, and a national park representing an area not affected by agriculture. A total of 288 soil, fecal floor, and water samples were collected from cattle operations, from the city of Fort Collins, and from Rocky Mountain National Park (RMNP) in Colorado. In addition, a total of 42 new and unused feed, unused bedding, compost, and manure samples were obtained from the cattle operations. Total, tetracycline-resistant, and ceftiofur-resistant bacterial populations were enumerated by both standard culture plating and real-time PCR methods. Only wastewater samples from the cattle operations demonstrated both higher tetracycline-resistant bacterial counts (enumerated by the culture plating method) and tetracycline resistance gene copies (quantified by real-time PCR) compared to water samples collected from non-farm environments. The ceftiofur resistance gene, blaCMY-2, was not detectable in any of the samples, while the tetracycline resistance genes examined in this study, tet(B), tet(C), tet(W), and tet(O), were detected in all types of tested samples, except soil samples from RMNP. Tetracycline resistance gene pools quantified from the tet(O) and tet(W) genes were bigger than those from the tet(B) and tet(C) genes in fecal and water samples. Although only limited resistance genes, instead of a full set, were selected for real-time PCR quantification in this study, our results point to the need for further studies to determine natural and urban impacts on antibiotic resistance.


Author(s):  
Cody P Doolan ◽  
Thomas Louie ◽  
Christopher Lata ◽  
Oscar E Larios ◽  
William Stokes ◽  
...  

Abstract Background Clostridioides difficile infection (CDI) is an opportunistic disease that lacks a gold standard test. Nucleic acid amplification tests (NAATs) such as real-time PCR demonstrate excellent an limit of detection (LOD) whereas antigenic methods are able to detect free toxin. Latent class analysis (LCA) provides an unbiased statistical approach to resolving true disease. Methods A cross-sectional study was conducted with suspected CDI patients (n=96). Four commercial real-time PCR tests, toxin antigen detection by enzyme immunoassay (EIA), toxigenic culture, and fecal calprotectin were performed. CDI clinical diagnosis was determined by consensus majority of three experts. LCA was performed using laboratory and clinical variables independent of any gold standard. Results Six LCA models were generated to determine CDI probability using four variables including toxin EIA, toxigenic culture, clinical diagnosis, and fecal calprotectin levels. Three defined zones as a function of real-time PCR cycle threshold (Ct) were identified using LCA: CDI likely (>90% probability), equivocal (<90% and >10%), CDI unlikely (<10%). A single model comprising toxigenic culture, clinical diagnosis, and toxin EIA showed the best fitness. The following Ct cut-offs for four commercial test platforms were obtained using this model to delineate three CDI probability zones: [GeneXpert ® : 24.00, 33.61], [Simplexa ® 28.97, 36.85], [Elite MGB ® 30.18, 37.43], and [BD Max ™ 27.60, 34.26]. Conclusion The clinical implication of applying LCA to CDI is to report Ct values assigned to probability zones based on the commercial real-time PCR platform. A broad range of equivocation suggests clinical judgement is essential to the confirmation of CDI.


Sign in / Sign up

Export Citation Format

Share Document