scholarly journals Myocardial injury after pulmonary vein isolation: fire versus ice

2021 ◽  
Vol 42 (Supplement_1) ◽  
Author(s):  
A R Morgado Gomes ◽  
N S C Antonio ◽  
S Silva ◽  
M Madeira ◽  
P Sousa ◽  
...  

Abstract Introduction The cornerstone of atrial fibrillation (AF) catheter ablation is pulmonary vein isolation (PVI), either using point-by-point radiofrequency ablation (RF) or single-shot ablation devices, such as cryoballoon ablation (CB). However, achieving permanent transmural lesions is difficult and pulmonary vein (PV) reconnection is common. Elevation of high-sensitivity Troponin I (hsTnI) may be used as a surrogate marker for transmural lesions. Still, data regarding the comparison of hsTnI increase after PVI with RF or cryo-energy is controversial. Purpose The aim of this study is to compare the magnitude of hsTnI elevation after PVI with CB versus RF using ablation index guidance. Methods Prospective study of 60 patients admitted for first ablation procedure of paroxysmal or persistent AF in a single tertiary Cardiology Department. Thirty patients were submitted to PVI using CB and 30 patients were submitted to RF, using CARTO® mapping system and ablation index guidance. Patients with atrial flutter were excluded. Baseline characteristics were compared between groups, as well as hsTnI before and after the procedure. Results Mean age was 57.9±12.3 years old, 62% of patients were male and 77% had paroxysmal AF. There were no significant differences between groups regarding gender, age, prevalence of hypertension, dyslipidaemia, diabetes, obesity or AF type. There was also no significant difference in electrical cardioversion need during the procedure. HsTnI median value before ablation was 1.90±1.98 ng/dL. Postprocedural hsTnI was significantly higher in CB-group (6562.7±4756.2 ng/dL versus 1564.3±830.7 ng/dL in RF-group; P=0.001). Regarding periprocedural complications, there was only one case of mild pericardial effusion in RF-group associated with postablation hsTnI of 1180.0 ng/dL. Conclusions High-sensitivity Troponin I was significantly elevated after PVI, irrespective of the ablation technique. In CB-group, hsTnI elevation was significantly higher than in RF-group. This disparity may reflect more extensive lesions with cryoablation, without compromising safety. Longterm studies are needed to understand whether this hsTnI elevation is predictive of a lower AF recurrence rate. FUNDunding Acknowledgement Type of funding sources: None.

EP Europace ◽  
2021 ◽  
Vol 23 (Supplement_3) ◽  
Author(s):  
I Antoun ◽  
S Bharat ◽  
A Mavilakandy ◽  
V Pooranachandran ◽  
GA Ng

Abstract Funding Acknowledgements Type of funding sources: None. Pulmonary vein isolation (PVI) is an effective and established therapy for paroxysmal atrial fibrillation (PAF) . PVI can be performed using point by point ablation with radiofrequency (RF) or with single shot techniques such as cryoballoon (CRYO). As P waves represent atrial depolarization, we aimed to study whether P wave metrics may change after PVI and if there are differences between RF and CRYO approaches. Methods We studied 88 matched patients who had PVI for PAF between January 2017 and December 2018 (RF = 44, CRYO = 44). Each patient was in sinus rhythm (SR) prior to ablation. Patients on amiodarone and those who had additional linear ablation were excluded. Patients had continuous ECG monitoring using Labsystem Pro (Boston Scientific Inc). Sampled at 1kHz during the procedure. One-minute recordings before and after PVI were exported and analysed using custom-written software using MatLab (v2018, bandpass 1-50Hz) to annotate P wave onset, peak and end. P wave duration was heart rate corrected (PWDc) by using the Hodges formula and P wave amplitude (PWA). Results P wave metrics were comparable before PVI between both cohorts. Successful PVI was achieved in all patients. There was a trend towards an increase in PWDc in some ECG leads with either RF or CRYO but no significant difference in P wave metrics as a result of PVI ablation or between both ablation modalities. Conclusion In this study, there was no significant change seen in PVI with RF or CRYO and no difference between the 2 ablation modalities. P wave metrics comparison, RF vs CRYO PWDc (ms) PRE, RF (n = 44) POST, RF (n = 44) P PRE, CRYO (n = 44) POST CRYO (n = 44) P P (RF vs CRYO) I 134.7 ± 32 133.5 ± 35 0.813 131.9 ± 36 132.7 ± 39 0.9 0.81 II 140.9 ± 34 144.1 ± 37 0.56 139.4 ± 42 134.4 ± 40 0.51 0.41 III 131.5 ± 31 143.3 ± 37 0.04 132.8 ± 41 130.6 ± 36 0.68 0.074 AVF 137 ± 32 144.7 ± 36 0.15 137.5 ± 42 127.4 ± 37 0.11 0.141 V1 143.9 ± 33 151.8 ± 37 0.17 133.6 ± 37 143.8 ± 38 0.09 0.745 PWA (mV) PRE, RF (n = 44) POST, RF (n = 44) P PRE, CRYO (n = 44) POST CRYO (n = 44) P P (RF vs CRYO) I 0.125 ± 0.08 0.09 ± 0.06 0.002 0.13 ± 0.08 0.14 ± 0.09 0.59 0.076 II 0.238 ± 0.1 0.238 ± 0.1 0.98 0.232 ± 0.1 0.278 ± 0.2 0.1 0.212 III 0.149 ± 0.1 0.153 ± 0.1 0.83 0.189 ± 0.1 0.187 ± 0.1 0.97 0.86 AVF 0.195 ± 0.1 0.196 ± 0.1 0.92 0.197 ± 0.1 0.247 ± 0.1 0.066 0.132 V1 0.122 ± 0.1 0.151± 0.1 0.05 0.138 ± 0.1 0.193 ± 0.2 0.002 0.543 PWDc and PWA comparison following RF vs CRYO.


Author(s):  
Cathrin Theis ◽  
Bastian Kaiser ◽  
Philipp Kaesemann ◽  
Felix Hui ◽  
Giancarlo Pirozzolo ◽  
...  

Background The single procedure success rates of durable pulmonary vein isolation (PVI) for paroxysmal atrial fibrillation (AF) varies between 80 and 90 %. This prospective, randomized study investigated the efficacy of Cryoballoon PVI (CBA) versus pulmonary vein isolation with RF-energy following the CLOSE protocol in terms of single-procedure arrhythmia-free outcome and safety. Methods and results A total number of 150 patients undergoing de-novo catheter ablation for paroxysmal AF were randomized to two different treatment arms in a 1:1 fashion. In group-A patients, PVI was performed with the Cryoballoon (Articfront Balloon, Medtronic Inc). The ablation procedure in group B was performed with RF-energy (CARTO 3, Biosense Webster Thermocool STSF), following the CLOSE protocol. During a mean follow-up of 12  4.5 months after a single procedure, 64 (85.33 %) patients of group A were free of arrhythmia recurrence versus 65 (86.67 %) patients in group B (p=ns). A total of 14 patients (group A: 7 (9.33 %) group B: 7 (9.33 %); p=ns) underwent a redo-procedure. No significant difference between both groups was observed in terms of PV recovery (group A: 4 (5.33 %) vs. group B: 3 (4 %); p=ns). Patients of group A showed significantly more AF recurrence during the blanking period of three months (group A: 14 (18.67 %) versus group B: 6 (8 %); p<0.05. Conclusions Cryoballoon PVI and PVI using ablation index following the CLOSE protocol are equally efficient in achieving durable PV-isolation. Cryoballoon ablation leads to significantly more AF recurrence during the blanking period.


2020 ◽  
Author(s):  
Karolina Weinmann ◽  
Regina Heudorfer ◽  
Alexia Lenz ◽  
Deniz Aktolga ◽  
Manuel Rattka ◽  
...  

AbstractImmobilization of patients during electrophysiological procedures, to avoid complications by patients’ unexpected bodily motion, is achieved by moderate to deep conscious sedation using benzodiazepines and propofol for sedation and opioids for analgesia. Our aim was to compare respiratory and hemodynamic safety endpoints of cryoballoon pulmonary vein isolation (PVI) and electroanatomical mapping (EAM) procedures. Included patients underwent either cryoballoon PVI or EAM procedures. Sedation monitoring included non-invasive blood pressure measurements, transcutaneous oxygen saturation (tSpO2) and transcutaneous carbon-dioxide (tpCO2) measurements. We enrolled 125 consecutive patients, 67 patients underwent cryoballoon atrial fibrillation ablation and 58 patients had an EAM and radiofrequency ablation procedure. Mean procedure duration of EAM procedures was significantly longer (p < 0.001) and propofol doses as well as morphine equivalent doses of administered opioids were significantly higher in EAM patients compared to cryoballoon patients (p < 0.001). Cryoballoon patients display higher tpCO2 levels compared to EAM patients at 30 min (cryoballoon: 51.1 ± 7.0 mmHg vs. EAM: 48.6 ± 6.2 mmHg, p = 0.009) and at 60 min (cryoballoon: 51.4 ± 7.3 mmHg vs. EAM: 48.9 ± 6.6 mmHg, p = 0.07) procedure duration. Mean arterial pressure was significantly higher after 60 min (cryoballoon: 84.7 ± 16.7 mmHg vs. EAM: 76.7 ± 13.3 mmHg, p = 0.017) in cryoballoon PVI compared to EAM procedures. Regarding respiratory and hemodynamic safety endpoints, no significant difference was detected regarding hypercapnia, hypoxia and episodes of hypotension. Despite longer procedure duration and deeper sedation requirement, conscious sedation in EAM procedures appears to be as safe as conscious sedation in cryoballoon ablation procedures regarding hemodynamic and respiratory safety endpoints.


EP Europace ◽  
2021 ◽  
Vol 23 (Supplement_3) ◽  
Author(s):  
D De Campos ◽  
L Puga ◽  
P Sousa ◽  
N Antonio ◽  
L Elvas

Abstract Funding Acknowledgements Type of funding sources: None. Introduction Ablation Index (AI) software has been associated with better freedom from atrial arrhythmias after pulmonary vein isolation (PVI) for paroxysmal atrial fibrillation (AF). There is conflicting data regarding the relationship between high sensitivity cardiac Troponin I (Hs-cTnI) and arrhythmia recurrence. The objective was to evaluate the impact of AI on Hs-cTnI level and on ablation effectiveness quotient (AEQ) and to assess if these markers are predictors of arrhythmia recurrence.  Methods Prospective observational study of consecutive patients referred for PVI for paroxysmal AF ablation from October 2017 to June 2018 according to a pre-specified AI protocol. Procedural endpoints and 2-year follow-up outcomes were assessed and compared to a retrospective cohort of conventional PVI contact-force-guided group .  Results A total of 56 patients were included: 29 patients the AI group and 27 patients in the control group. The mean age was 60.5 ± 10.3 years, 48% males. Left ventricular ejection fraction (60 ± 6 % AI vs 61 ± 5 % control, P = 0.07) and left atrium diameter (43 ± 7 mm AI vs 44 ± 6 mm control, P = 0.58) were comparable between groups. First-pass isolation was shown to be higher in the AI group (79% AI vs 44%, p= 0.01). Mean number of radiofrequency applications was lower in the AI group (93 ± 24 vs 111 ± 30, P = 0.02). Average contact-force was similar between groups (17.6 ± 4.1 g vs 22.6 ± 10.7 g, P =0.166). Patients that performed PVI guided by the AI had lower Hs-cTnI (1815 ± 1146 ng/L vs 3274 ± 1696 ng/L, p &lt; 0.001) and lower AEQ (1.01 ± 0.7 ng/L/s vs 1.51 ± 0.7 ng/L/s, P = 0.011) compared to patients in the control group. During a mean follow-up of 26 ± 11 months, AF recurrence was documented in 10.3% of patients in the AI group and 22.2% in the control group (P = 0.223). Neither Hs-cTnI nor AEQ levels were predictors of arrhythmia recurrence.  Conclusions These data suggest that AI-guided catheter ablation is associated with reduced levels of of Hs-cTnI and AEQ. Neither Hs-cTnI and AEQ should be used to predict arrhythmia recurrence. Abstract Figure.


Heart Rhythm ◽  
2021 ◽  
Vol 18 (8) ◽  
pp. S137
Author(s):  
Christian H. Heeger ◽  
Roza Meyer-Saraei ◽  
Charlotte Eitel Thomas Fink ◽  
Bettina Kirstein ◽  
Michael Schlüter ◽  
...  

EP Europace ◽  
2021 ◽  
Vol 23 (Supplement_3) ◽  
Author(s):  
SA Reddy ◽  
SL Nethercott ◽  
BV Khialani ◽  
MS Virdee

Abstract Funding Acknowledgements Type of funding sources: None. Background Over the last 20 years various techniques have been developed striving for safer and more durable pulmonary vein isolation (PVI). The three most commonly used tools are pulmonary vein ablation catheter (PVAC) and cryoballoon (‘single-shot’ techniques), and point-by-point (PBP) radiofrequency ablation using 3D electroanatomical mapping (EAM). Objective Evaluate the safety and efficacy of the different techniques in an unselected population undergoing de-novo ablation for persistent or paroxysmal atrial fibrillation (AF) at a single high-throughput centre. Method Retrospective, single-centre study of consecutive AF ablations between March 2017 and April 2018. Demographic, procedural and outcome data were analysed. Results Over the study period 329 first-time PVI procedures were performed. 37.4% were performed using PBP, 39.8% using cryoballoon and 22.8% using PVAC. There was no significant difference in age or sex between different ablation technique groups. 238 procedures were performed for paroxysmal AF and 91 for persistent AF. A higher proportion of the persistent cases were performed using point-by-point techniques compared to paroxysmal cases (58.2% vs 29.0%, p &lt; 0.05). Procedural times were significantly longer in the group undergoing PBP ablation compared to cryoballoon or PVAC. However, there was no statistically significant difference in 12-month freedom from symptomatic AF or procedural complications between the groups. Conclusions PBP, PVAC and cryoballoon AF ablation all appeared equally efficacious in an unselected population, though PVAC and cryoballoon procedures were shorter. All procedures were associated with a low adverse event rate. Prospective examination is required to substantiate this finding. Table 1CARTOn= 123Cryoballoonn= 131PVACn = 75p-valueAge/years61.7 ± 9.259.5 ± 10.661.7 ± 9.70.14Male92 (74.8)88 (67.2)49 (61.3)0.80Paroxysmal AF70 (56.9)106 (78.6)62 (82.7)0.14Cardiovascular risk factors Hypertension Diabetes Ischaemic heart disease Cerebrovascular disease Heart failure Dyslipidaemia73 (59.3)23 (18.7)40 (32.5)2 (1.6)0 (0) 12 (9.8)79 (60.3)19 (14.5)45 (34.4)0 (0)1 (0.8)16 (12.2)43 (57.3)16 (21.3)22 (29.3)1 (1.3)0 (0)10 (13.3) 0.58 0.24 0.62 - - 0.71Left atrial diameter/cm4.2 ± 0.74.1 ± 0.73.9 ± 1.00.69Procedure time/mins191.3 ± 39126.7 ± 24117.4 ± 30&lt;0.056 month success Paroxysmal Persistent50/66 (75.8)32/51 (62.7)78/103 (75.7)18/24 (75.0)48/61 (78.6)10/12 (83.3) 0.99 0.80Complications9 (7.3)3 (2.3)1 (1.3)0.07Patient demographics, procedural characteristics and outcomes for Carto, cryoballoon and PVAC cases. Values presented as mean ± SD or n (%)Abstract Figure. Time to arrhythmia recurrence


2019 ◽  
Vol 40 (Supplement_1) ◽  
Author(s):  
M Yano ◽  
M Nishino ◽  
H Nakamura ◽  
Y Matsuhiro ◽  
K Yasumura ◽  
...  

Abstract Background High sensitive cardiac troponin I (hs-TnI), subunit of cardiac troponin complex, is a sensitive and specific marker of myocardium injury as troponin T. Several studies showed hs-TnI was associated with worse cardiovascular outcomes but relationship between serum hs-TnI level in patients with atrial fibrillation (AF) after pulmonary vein isolation (PVI) and AF recurrence remains unclear. Methods We enrolled 444 consecutive AF patients who underwent PVI from May 2017 to September 2018. We investigated the difference of relationship between serum hs-TnI, inflammation markers at 48 hours after PVI and early or late recurrence of AF (ERAF, <3 months and LRAF, during 1 year after PVI in patients with AF) between radiofrequency ablation (RFA) group and cryoballoon ablation (CBA) group. Results RFA and CBA were performed in 328 and 116 patients, respectively. There were no significant differences in patient characteristics between RFA group and CBA group. Serum hs-TnI in RFA group was significantly lower than in CBA group (1.93 ng/ml±3.28 vs 5.08 ng/ml±4.29, p<0.001), while hs-CRP was significantly higher in RFA group than CB group (1.97±2.38 mg/dl vs 1.10±0.84 mg/dl, p<0.001). The incidence of ERAF was similar between the two groups (RFA group: 26.8% and CBA group: 21.6%, p=0.262). There was no significant difference of hs-TnI and hs-CRP between patients with ERAF and without ERAF (table). In 213 patients who were followed during 1 year (PVIs were performed from May 2017 to January 2018, RFA 149 and CBA 64 patients), there was no significant association between hs-TnI, hs-CRP and incidence of LRAF (table). TnI and CRP between RFA and CBA RFA (n=328) CBA (n=116) P value hs-TnI 1.93±3.28 5.08±4.29 <0.001 hs-CRP 1.97±2.38 1.10±0.84 <0.001 3 months follow-up RFA (n=328) CBA (n=116) ERAF (+) ERAF (−) P value ERAF (+) ERAF (−) P value hs-TnI 1.68±1.90 2.02±3.66 0.410 5.03±3.17 5.10±4.56 0.943 hs-CRP 2.23±2.65 1.88±2.27 0.238 1.01±0.84 1.13±0.85 0.524 1 year follow-up RFA (n=149) CBA (n=64) LRAF (+) LRAF (−) P value LRAF (+) LRAF(−) P value hs-TnI 1.61±1.77 1.87±2.69 0.570 4.71±2.14 5.60±5.69 0.664 hs-CRP 2.18±2.24 1.92±2.24 0.550 1.12±0.64 1.12±0.98 0.991 Conclusion CBA may cause more myocardial injury than RFA, on the contrary RFA may cause more inflammation than CBA. These markers did not affect ERAF and LRAF after PVI.


2018 ◽  
Vol 7 (1) ◽  
pp. 11 ◽  
Author(s):  
Shaojie Chen ◽  
Boris Schmidt ◽  
Stefano Bordignon ◽  
Fabrizio Bologna ◽  
Takahiko Nagase ◽  
...  

Catheter ablation is the most effective treatment option for patients suffering from symptomatic atrial fibrillation. Electrical isolation of the pulmonary veins is the procedural cornerstone. Point-by-point radiofrequency current energy ablation in combination with a 3D electro-anatomical mapping system is the established approach to ablation. In contrast, cryoballoon ablation uses a single-shot approach to facilitate pulmonary vein isolation. However, fixed cryoballoon diameters (28 mm or 23 mm) and non-balloon compliance can lead to technical difficulties in isolating variable pulmonary vein anatomies. This review focuses on key procedural aspects and illustrates practical techniques in cryoballoon pulmonary vein isolation to shorten the learning curve without compromising safety and efficacy. It has a special emphasis on inferior pulmonary veins.


EP Europace ◽  
2021 ◽  
Vol 23 (Supplement_3) ◽  
Author(s):  
RRT Tilz ◽  
RMS Meyer-Saraei ◽  
JV Vogler ◽  
TF Fink ◽  
VS Sciacca ◽  
...  

Abstract Funding Acknowledgements Type of funding sources: None. Background The arctic front cryoballon (AF-CB) provides effective and durable pulmonary vein isolation (PVI) associated with encouraging clinical outcome data. The POLARx cryoballoon incorporates unique features which may translate into improved efficacy and safety. Purpose To assess efficacy and safety of the novel POLARx cryoballoon in comparison to the fourth generation arctic front cryoballon (AF-CB4). Methods Twenty-five consecutive patients with paroxysmal or persistent atrial fibrillation (AF) were prospectively enrolled, underwent POLARx based PVI (POLARx group) and were compared to 25 consecutive patients treated with the fourth generation AF-CB (AF-CB4 group). Results A total of 100 (POLARx) and 97 (AF-CB4) pulmonary veins (PV) were identified and all PVs were successfully isolated utilizing the POLARx and AF-CB4, respectively. A significant difference regarding the mean minimal cryoballoon temperatures reached using the AF-CB4 and POLARx (-50 ± 6°C vs. -57 ± 7°C, p = 0.004) was observed. Real-time PVI was visualized in 81% of POLARx patients and 42% of AF-CB4 patients (p &lt; 0.001). Despite a certain learning curve utilizing the POLARx a trend towards shorter median procedure time (POLARx: 45 (39, 53) minutes vs. AF-CB4: 55 (50, 60) minutes (p = 0.062) was found. No differences were observed for periprocedural complications. Conclusions The novel POLARx showed similar safety and efficacy compared to the AF-CB4. A higher rate of real-time electrical PV recordings and significantly lower balloon temperatures were observed using the POLARx as compared to AF-CB4.


2021 ◽  
Author(s):  
Roland Richard Tilz ◽  
Roza Meyer-Saraei ◽  
Charlotte Eitel ◽  
Thomas Fink ◽  
Vanessa Sciacca ◽  
...  