scholarly journals P5751Long-term outcome of radiofrequency catheter ablation for redo procedures after pulmonary vein isolation with the cryoballoon technique (first versus second generation cryoballoon)

2018 ◽  
Vol 39 (suppl_1) ◽  
Author(s):  
K Kettering ◽  
F Gramley
EP Europace ◽  
2020 ◽  
Vol 22 (Supplement_1) ◽  
Author(s):  
K Kettering

Abstract Catheter ablation has become the first line of therapy in patients with symptomatic, recurrent, drug-refractory atrial fibrillation. Cryoablation has been shown to be a safe and effective technique for pulmonary vein isolation. However, there is a significant arrhythmia recurrence rate after cryoablation procedures and there are no established strategies for redo procedures in these patients. Therefore, we have summarized our experience with radiofrequency catheter ablation for redo procedures after pulmonary vein isolation with the cryoballoon technique (including an analysis of pulmonary vein conduction recovery patterns ater procedures performed with the first or second generation cryoballoon). Methods One hundred and twenty patients (paroxysmal AF: 78 patients, persistent AF: 42 patients) had to undergo a redo procedure after initially successful circumferential PV isolation with the cryoballoon technique. The redo ablation procedures were performed using a segmental approach or a circumferential ablation strategy depending on the intra-procedural findings. Results During the redo procedure, a mean number of 1.8 re-conducting PVs were detected (using a circular mapping catheter; group A: 2.1 re-conducting PVs, group B: 1.5 re-conducting PVs). There was a slightly higher incidence of chronic PV reconnections related to the left-sided PV ostia than to the right-sided PVs in both groups. Furthermore, sites of chronic PV reconnection were found more frequently in the inferior parts of the PV ostia than in the superior parts. In 53 patients in group A, a segmental approach was sufficient to eliminate the residual PV conduction because there were only a few recovered PV fibers (1-3 reconnected PVs; group A1). In the remaining 7 patients in group A, a circumferential ablation strategy was used because of a complete recovery of the PV-LA conduction of all four pulmonary veins (group A2). In group B, a segmental approach was sufficient in all patients because there was only a minor  reconnection of 1-2 PVs. All recovered PVs could be isolated sucessfully again. At 42-month follow-up, 78 % of all patients were free from an arrhythmia recurrence (94/120 patients; group A: 43/60 patients (71 %), group B: 51/60 patients (85 %)). There were no major complications in both groups. Conclusions In patients with an initial circumferential PVI using the cryoballoon technique, a repeat ablation procedure can be performed safely and effectively using radiofrequency catheter ablation. In most cases only a few re-conducting PV fibers were found and therefore, a segmental re-ablation approach seems to be sufficient in the majority of patients (especially in patients treated with the second generation cryoballoon).


EP Europace ◽  
2017 ◽  
Vol 20 (FI_3) ◽  
pp. f286-f287
Author(s):  
Christian-Hendrik Heeger ◽  
Andreas Metzner ◽  
Karl-Heinz Kuck ◽  
Feifan Ouyang

Heart Rhythm ◽  
2014 ◽  
Vol 11 (4) ◽  
pp. 549-556 ◽  
Author(s):  
Alex J.A. McLellan ◽  
Liang-han Ling ◽  
Diego Ruggiero ◽  
Michael C.G. Wong ◽  
Tomos E. Walters ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document