P3778Long-term outcome of non-pharmacologial treatment of atrial fibrillation in hypertrophic cardiomyopathy: a large single-centre experience

2019 ◽  
Vol 40 (Supplement_1) ◽  
Author(s):  
L Dinshaw ◽  
M Lemoine ◽  
J Hartmann ◽  
B Schaeffer ◽  
N Klatt ◽  
...  

Abstract Introduction Atrial fibrillation (AF) is common in hypertrophic cardiomyopathy (HCM) and is generally associated with a significant deterioration of clinical status. Non-pharmacological treatment such as surgical and catheter ablation has become an established therapy for symptomatic AF but in patients with HCM often having a chronically increased left atrial pressure and extensive atrial cardiomyopathy the long-term outcome is uncertain. Purpose The present study aimed to analyse the long-term outcome of AF ablation in HCM and the mechanism of recurrent atrial arrhythmias using high-density mapping systems. Methods A total of 65 patients (age 64.5±9.9 years, 42 (64.6%) male) with HCM undergoing AF ablation for symptomatic AF were included in our study. The ablation strategy for catheter ablation included pulmonary vein isolation in all patients and biatrial ablation of complex fractionated electrograms with additional ablation lines if appropriate. In patients with suspected atrial tachycardia (AT) high-density activation and substrate mapping were performed. A surgical ablation at the time of an operative myectomy for left ventricular outflow tract obstruction was performed in 8 (12.3%) patients. The outcome was analysed using clinical assessment, Holter ECG and continuous rhythm monitoring of cardiac implantable electric devices. Results Paroxysmal AF was present in 27 (41.6%), persistent AF in 37 (56.9%) and primary AT in 1 (1.5%) patients. The mean left atrial diameter was 54.1±12.5 ml. In 11 (16.9%) patients with AT high-density mapping was used to characterize the mechanism of the ongoing tachycardia. After 1.9±1.2 ablation procedures and a follow-up of 48.5±37.2 months, ablation success was demonstrated in 58.9% of patients. The success rate for paroxysmal and persistent AF was 70.0% and 55.8%, respectively (p=0.023). Of those patients with AT high-density mapping guided ablation was successful in 44.4% of patients. The LA diameter of patients with a successful ablation was smaller (52.2 vs. 58.1 mm; p=0.003). Conclusion Non-pharmacological treatment of AF in HCM is effective during long-term follow-up. Paroxysmal AF and a smaller LA diameter are favourable for successful ablation. In patients with complex AT the use of high-density mapping can guide ablation resulting in further ablation success in a reasonable number of patients.

2009 ◽  
Vol 20 (11) ◽  
pp. 1211-1216 ◽  
Author(s):  
LI-WEI LO ◽  
YENN-JIANG LIN ◽  
HSUAN-MING TSAO ◽  
SHIH-LIN CHANG ◽  
AMEYA R. UDYAVAR ◽  
...  

2020 ◽  
Vol 75 (4) ◽  
pp. 352-359
Author(s):  
Takafumi Oka ◽  
Koji Tanaka ◽  
Yuichi Ninomiya ◽  
Yuko Hirao ◽  
Nobuaki Tanaka ◽  
...  

Circulation ◽  
2015 ◽  
Vol 132 (suppl_3) ◽  
Author(s):  
Sanghamitra Mohanty ◽  
Prasant Mohanty ◽  
Luigi Di Biase ◽  
Chintan Trivedi ◽  
Rong Bai ◽  
...  

Background: Left atrial (LA) scarring, a consequence of cardiac fibrosis is a powerful predictor of procedure-outcome in atrial fibrillation (AF) patients undergoing catheter ablation. We sought to compare the long-term outcome in patients with paroxysmal AF and severe LA scarring/fibrosis identified by 3D mapping undergoing ablation of the pulmonary veins (PVAI) only or PVAI and the entire scar areas (scar homogenization) or PVAI plus ablation of the non-PV triggers. Methods: One-hundred seventy seven consecutive patients with paroxysmal atrial fibrillation and severe left atrial scarring were included in this study. LA scarring was diagnosed by 3D voltage mapping. The degree of scar was described as severe when >60% of the LA area was involved. Non-PV triggers were defined as ectopic triggers originating from sites other than pulmonary veins such as interatrial septum, superior vena cava, left atrial appendage, ligament of Marshall, crista terminalis and coronary sinus. Patients underwent ablation of the pulmonary vein antrum (PVAI) only (n=45, group 1), PVAI extended to the entire scar areas (scar homogenization [n=66, group 2]) or PVAI plus ablation of non-PV triggers (n=66, group 3). Choice of ablation strategy was determined by the operator. Patients were followed up for arrhythmia recurrence with event recorders, ECG and Holter monitoring. Results: Baseline characteristics were not different between the groups (age 63±9 vs 58±10 vs. 60±11 years, p=0.23; male 71%, vs. 72% vs. 73% p= 0.91). After a single procedure, all patients were followed-up for a minimum of two years. The long-term success rate at the end of the follow up was 19% (12 pts) in group 1, 21% (14 pts) in group 2, and 61% (40 pts) in group 3. Kaplan-Meier log-rank test indicated that the cumulative probability of AF-free survival was significantly higher in group 3 (overall log-rank p <0.001, pairwise comparison 1 vs. 3 and 2 vs. 3 was significant at p<0.01). Conclusions: In patients with paroxysmal atrial fibrillation and severe left atrial scarring, PVAI plus ablation of non-PV triggers is associated with significantly better long-term outcome than PVAI alone or when PVAI is combined with scar homogenization.


EP Europace ◽  
2021 ◽  
Vol 23 (Supplement_3) ◽  
Author(s):  
P Silverio Antonio ◽  
G Lima Da Silva ◽  
T Rodrigues ◽  
N Cunha ◽  
S Couto Pereira ◽  
...  

Abstract Funding Acknowledgements Type of funding sources: None. Introduction and objective Radiofrequency catheter ablation (RCA) for ventricular tachycardia (VT) in patients with ischemic heart disease (IHD) is associated with a reduced risk of VT storm and implantable cardioverter defibrillator (ICD) shocks. We aim to report the long-term outcome after a single RCA procedure for VT in patients with IHD using a high-density substrate-based approach. Methods We conducted a prospective, observational, single-centre and single-arm study involving patients with IHD, referred for RCA procedure for VT using high-density mapping catheters. Substrate mapping was performed in all patients. Procedural endpoints were VT noninducibility and local abnormal ventricular activities (LAVAs) elimination. The primary end point was survival free from appropriate ICD shocks and secondary end points included VT storm and all-cause mortality. Results Sixty-four consecutive patients were included (68 ± 9 years, 95% male, mean ejection fraction 33 ± 11% , 39% VT storms, and 69% appropriate ICD shocks). LAVAs were identified in all patients and VT inducibility was found in 83%. LAVAs elimination and noninducibility were achieved in 93.8% and 60%, respectively. After a mean follow-up of 25 ± 18 months, 90% and 85% of patients are free from appropriate ICD shocks at 1 and 2 years, respectively. The proportion of patients experiencing VT storm decreased from 39% to 1.6%. Overall survival was 89% and 84% at 1 and 2 years, respectively. Conclusions RCA of VT in IHD using a high-density mapping substrate-based approach resulted in a long-term steady freedom of ICD shocks and VT storm. Abstract Figure. Appropriate shock & all cause mortality


2020 ◽  
Author(s):  
Fares-Alexander Alken ◽  
Shaojie Chen ◽  
Mustafa Masjedi ◽  
Helmut Pürerfellner ◽  
Philippe Maury ◽  
...  

Aim: Ultra-high-density mapping (HDM) is increasingly used for guidance of catheter ablation in cardiac arrhythmias. While initial results are promising, a systematic evaluation of long-term outcome has not been performed so far. Methods: A systematic review and meta-analysis was conducted on studies investigating long-term outcome after Rhythmia HDM-guided atrial fibrillation (AF) or atrial tachycardia catheter ablation. Results: Beyond multiple studies providing novel insights into arrhythmia mechanisms, follow-up data from 17 studies analyzing Rhythmia HDM-guided ablation (1768 patients, 49% with previous ablation) were investigated. Cumulative acute success was 100/90.2%, while 12 months long-term pooled success displayed at 71.6/71.2% (AF/atrial tachycardia). Prospective data are limited, showing similar outcome between HDM-guided and conventional AF ablation. Conclusion: Acute results of HDM-guided catheter ablation are promising, while long-term success is challenged by complex arrhythmogenic substrates. Prospective randomized trials investigating different HDM-guided ablation strategies are warranted and underway.


EP Europace ◽  
2003 ◽  
Vol 4 (Supplement_2) ◽  
pp. B130-B130
Author(s):  
H. Mlcochova ◽  
R. Cihak ◽  
J. Kautzner ◽  
J. Bytesnik ◽  
V. Vancura ◽  
...  

Circulation ◽  
2015 ◽  
Vol 132 (suppl_3) ◽  
Author(s):  
Xue Zhao ◽  
Jianqiang Hu ◽  
Yan Huang ◽  
Yawei Xu ◽  
Yanzhou Zhang ◽  
...  

Objectives: The aim of this study was to determine the mechanisms and effectiveness of pulmonary antrum radial-linear (PAR) ablation in comparison with pulmonary vein isolation (PVI) in patients with paroxysmal atrial fibrillation (AF) after a long-term follow-up. Background: The one-year follow up data suggested that PAR ablation appeared to have a better outcome over the conventional PVI for paroxysmal AF. Methods: The enrollment occurred between March, 2011, and August, 2011, with the last follow-up in May, 2014. A total of 133 patients with documented paroxysmal AF were enrolled from 5 centers and randomized to PAR group or PVI group. Event ECG recorder and Holter monitoring were conductedduring the follow-up for all patients. Results: The average procedure time was 151±23 min in PAR group and 178±43 min in PVI group ( P <0.001). The average fluoroscopy time was 21±7 min in PAR group and 27±11 min in PVI group ( P= 0.002). AF triggering foci were eliminated in 59 patients (89.4%) in PAR group, whereas, only 4 patients (6.0%) in PVI group (P<0.001).At median 36 (37-35) months of follow-up after single ablation procedure, 43 of 66 patients in PAR group (65%) and 28 of 67 patients in PVI group (42%) had no recurrence of AF off antiarrhythmic drug (AAD) (P=0.007); and 47 of 66 patients in PAR group (71%) and 32 of 67 patients in PVI group (48%) had no recurrence of AF with AAD (P=0.006). At the last follow-up, the burden of AF was significantly lower in PAR group than in PVI group (0.9% ± 2.3% vs 4.9% ± 9.9%;90th percentile, 5.5% vs 19.6%; P=0.008). No major adverse event (death, stroke, PV stenosis) was observed in all the patients except one case of pericardial tamponade. Conclusions: PAR ablation is a simple, safe, and effective strategy for the treatment of paroxysmal AF with better long-term outcome than PVI. PAR ablation might exhibit the beneficial effect on AF management through multiple mechanisms. Registration: ChiCTR-TRC-11001191


Circulation ◽  
2015 ◽  
Vol 132 (suppl_3) ◽  
Author(s):  
Erica S Zado ◽  
Pasquale Santangeli ◽  
Francis E Marchlinski

Introduction: Endo-epicardial catheter ablation of ventricular tachycardia (VT) in patients (pts) with nonischemic cardiomyopathy (NICM) has been reported to have satisfactory results at the short- and mid-term follow-up. We sought to determine the outcomes at the long-term follow-up of endo-epicardial ablation of VT in NICM. Hypothesis: Catheter ablation provides satisfactory long term outcome Methods: We prospectively enrolled 128 pts (age 59±13 years, 116 [91%] males) with NICM who underwent endo-epicardial radiofrequency catheter ablation at our Institution. After substrate mapping, all critical sites for the clinical or induced VT(s), identified with activation, entrainment or pace-mapping, together with late, split and fractionated potentials were targeted with focal and/or linear ablation. The procedural endpoint was noninducibility of sustained monomorphic VT. Pts were followed with ICD interrogation. Results: A total of 108 (73%) pts had idiopathic dilated NICM. The remaining 20 (14%) pts had hypertrophic CM (n=11), suspected inflammatory CM (n=6), or valvular CM (n=3). The mean LV ejection fraction was 33±15%. After a mean follow-up of 19 months (max 97 months), a total of 36 (28%) pts died and 17 (13%) underwent heart transplant. Cumulative survival free from any recurrent VT was 53% (68/128 patients) (Figure A). In the remaining 60 (47%) patients with VT recurrences, catheter ablation still resulted in a significant beneficial clinical impact on VT burden, with 25/60 (42%) having only isolated (1-2) VT episodes over follow-up, and a striking reduction of VT storm in the remaining pts (Figure B). Conclusions: In patients with NICM and VT, endo-epicardial substrate-based ablation is effective in achieving long-term freedom from any VT in 53% of patients, with a substantial improvement in VT burden in many of the remaining patients.


2012 ◽  
Vol 24 (3) ◽  
pp. 250-258 ◽  
Author(s):  
HUNG-YU CHANG ◽  
LI-WEI LO ◽  
YENN-JIANG LIN ◽  
SHIH-LIN CHANG ◽  
YU-FENG HU ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document