scholarly journals Catheter ablation for atrial fibrillation in very young patients

EP Europace ◽  
2021 ◽  
Vol 23 (Supplement_3) ◽  
Author(s):  
K Yalin ◽  
B Ikitimur ◽  
T Aksu ◽  
AU Soysal ◽  
E Lyan ◽  
...  

Abstract Funding Acknowledgements Type of funding sources: None. Introduction Pulmonary vein automaticity is an established trigger of paroxysmal atrial fibrillation (PAF) making pulmonary vein isolation (PVI)  the cornerstone for catheter ablation. However, data on triggers of AF and catheter ablation strategy in very young (<30 years old) patients are sparse. Methods and results: Sixteen young patients (mean age 25.2 ± 4.9 years; 75% men) with recurrent drug refractory PAF underwent EP study and ablation at 3 EP centers. None of the patients had structural heart disease or family history of AF. EP study revealed degeneration of induced supraventricular tachycardia (SVT) into AF in 5 patients (n = 5, 31.2%). Induced SVTs were left lateral concealed accessory pathway mediated orthodromic AVRT in two patients, typical AVNRT in two patients, and left superior PV tachycardia in one patient respectively. In patients with induced SVTs, SVT ablation without PVI was performed as an index procedure. Remaining patients underwent second generation cryoballoon (CB-2) based PVI (n = 11, 68.7%). There were no major complications related to ablation procedures. Follow-up was based on outpatient visits including 24-h Holter-ECG at 3, 6 and, 12 months post ablation, or additional Holter-ECG was ordered in case of symptoms suggesting recurrence. Recurrence was defined as any atrial tachyarrhythmia (ATA) episode >30s following a 3-month blanking period. After a median follow-up of 18.3 ± 6.2 months, 13 of 16 (81.2%) patients were free of ATA recurrence. None of the patients belonging to SVT ablation only group experienced ATA recurrence. Three patients with previous CB-2 PVI recurred, one had typical atrial flutter and underwent CTI ablation, remaining 2 patients had AF recurrence and medically followed. Conclusion In a considerable fraction of young adult patients with history of PAF SVTs may be responsible and SVT ablation without PVI may be sufficient as an index procedure. Catheter ablation AF seems to be safe and effective in this population.

2019 ◽  
Vol 29 (5) ◽  
pp. 643-648 ◽  
Author(s):  
Jindong Chen ◽  
Hao Wang ◽  
Mengmeng Zhou ◽  
Liang Zhao

AbstractBackground:To assess the effectiveness of radiofrequency catheter ablation for lone atrial fibrillation in young adults.Methods:This single-centre, retrospective, observational study enrolled 75 consecutive patients (86.7% men) under 35 (median, 30) years old with lone atrial fibrillation (68% paroxysmal, 26.7% persistent, and 5.3% long-standing persistent) without other cardiopulmonary diseases who underwent catheter ablation between April 2009 and May 2017. Procedural endpoints were circumferential pulmonary vein ablation for atrial fibrillation with pulmonary vein trigger, and target ablation or bidirectional block of lines and disappearance of complex fractionated atrial electrograms for atrial fibrillation with clear and unclear non-pulmonary vein triggers, respectively.Results:Main study outcome was rate of survival free from atrial tachyarrhythmia recurrence, which at median 61 (range, 5–102) months follow-up was 62.7% (64.7 and 58.3% for paroxysmal and non-paroxysmal atrial fibrillation, respectively) after single ablation, and 69.3% (68.6 and 70.8% for paroxysmal and non-paroxysmal atrial fibrillation, respectively) after mean 1.2 ablations (two and three ablations in 11 and 2 patients, respectively). In multivariate analysis, non-pulmonary vein trigger was a significant independent predictor of recurrent atrial tachyarrhythmia (OR, 10.60 [95%CI, 2.25–49.96]; p = 0.003). There were no major periprocedural adverse events.Conclusions:In patients under 35 years old with lone atrial fibrillation, radiofrequency catheter ablation appeared effective particularly for atrial fibrillation with pulmonary vein trigger and regardless of left atrial size or atrial fibrillation duration or type. Atrial tachyarrhythmia recurrence after multiple ablations warrants further study.


2010 ◽  
Vol 67 (1) ◽  
pp. 48-54 ◽  
Author(s):  
Nebojsa Mujovic ◽  
Miodrag Grujic ◽  
Stevan Mrdja ◽  
Aleksandar Kocijancic ◽  
Tatjana Potpara ◽  
...  

Background/Aim. The occurrence of atrial fibrillation (AF) in the presence of an accessory pathway (AP) that conducts rapidly is potentially lethal because the rapid ventricular response may lead to ventricular fibrillation (VF). The aim of the study was to determine long-term efficacy of AP catheter-ablation using radiofrequency (RF) current in secondary prevention of VF in WPW patients. Methods. Study included a total of 192 symptomatic WPW patients who underwent RF catheter-ablation of AP in our institution from 1994 to 2007 and were available for clinical follow-up for more than 3 months after procedure. Results. Before ablation, VF was recorded in total of 27 patients (14.1%). In 14 of patients (51.9%) VF was the first clinical manifestation of WPW syndrome. A total of 35 VF episodes were identified in 27 patients. The occurrence of VF was preceded by physical activity or emotional stress in 17.1% of cases, by alcohol abuse in 2.9% and by inappropriate intravenous drug administration in 28.6%. In addition, no clear precipitating factor was identified in 40% of VF cases, while informations about activities preceding 11.4% of VF episodes were not available. The follow-up of 5.7 ? 3.3 years was obtained in all of 27 VF patients. Of the 20 patients who underwent successful AP ablation, all were alive, without syncope or ventricular tachyarrhythmias during long-term follow-up. In 4 of 7 unsuccessfully treated patients, recurrence of supraventricular tachycardia and/or preexcited atrial fibrillation were recorded; one of these patients suddenly died of VF, 6 years after procedure. Conclusion. In significant proportion of WPW patients, VF was the first clinical manifestation of WPW syndrome, often precipitated by physical activity, emotional stress or inappropriate drug administration. Successful elimination of AP by percutaneous RF catheter-ablation is highly effective in secondary prevention of life-threatening tachyarrhythmias in patients with ventricular preexcitation.


Circulation ◽  
2020 ◽  
Vol 142 (Suppl_3) ◽  
Author(s):  
Nobuaki Tanaka ◽  
KOICHI INOUE ◽  
Atsushi Kobori ◽  
Kazuaki Kaitani ◽  
Takeshi Morimoto ◽  
...  

Background: Heart failure (HF) is the leading cause of death in patients with atrial fibrillation (AF). Radiofrequency catheter ablation (RFCA) of AF is effective for maintaining sinus rhythm though its impact on heart failure still remains controversial. Purpose: We sought to elucidate whether AF recurrence following RFCA was associated with subsequent HF hospitalizations. Methods: We conducted a large-scale, prospective, multicenter, observational study. A total of 4931 consecutive patients who underwent an initial RFCA for AF with longer than 1-year of follow-up in 26 centers were enrolled (average age, 64±10 years; non-paroxysmal AF, 35.7%). The median follow-up duration was 2.9 years. The primary endpoint was an HF hospitalization more than 1-year after the index RFCA. We compared the patients without AF recurrences (group A) to those with AF recurrences within 1-year post RFCA (group B). Results: The 1-year cumulative incidence of AF recurrences after a single procedure was 30.7% (group A=3418, group B=1513 patients). Group B had a lower body mass index (group A vs. group B,24.1±3.6 vs. 23.8±3.4 kg/m 2 , p=0.014), longer history of AF (1.9 vs. 3.1 years, p<0.0001), higher prevalence of non-paroxysmal AF (32.1% vs. 33.9%, p<0.0001), and valvular heart disease (5.9% vs. 7.8%, p=0.013). They also had a lower ejection fraction (63.7±9.4% vs. 62.8±9.6%, p=0.0043) and larger left atrial dimeter (39.7±6.6 vs. 40.6±7.0 mm, p<0.0001) on echocardiography. Hospitalizations for HF were observed in 57 patients (1.14%) more than 1-year after the RFCA and were significantly higher in group B than group A (group A vs. group B, 0.91% vs 1.72%, log-rank p=0.019). Conclusions: Among AF patients receiving RFCA, those with AF recurrences were at a greater risk of subsequent heart failure hospitalizations than those without AF recurrences. Recognition that AF recurrence following RFCA is a risk factor for a subsequent HF-related hospitalization is appropriate in clinical practice.


EP Europace ◽  
2021 ◽  
Vol 23 (Supplement_3) ◽  
Author(s):  
P Futyma ◽  
L Zarebski ◽  
A Wrzos ◽  
M Futyma ◽  
P Kulakowski

Abstract Funding Acknowledgements Type of funding sources: None. Background Pulmonary vein isolation (PVI) is a cornerstone for catheter ablation (CA) of atrial fibrillation (AF), however, long-term efficacy of PVI is frequently below expectations. PVI is invasive, expensive and may be associated with devastating complications. It has been postulated that vagally-mediated AF can be treated by attenuation of parasympathetic drive to the heart using cardioneuroablation by means of radiofrequency CA (RFCA) of the right anterior ganglionated plexus (RAGP), however, data in literature and guidelines are lacking. Purpose To examine the efficacy of RFCA targeting RAGP without PVI in management of vagal AF. Methods We included consecutive 9 male patients with vagal AF who underwent RFCA of RAGP without PVI. RAGP was targeted anatomically from the right atrium (RA) at the postero-septal area below superior vena cava (SVC) and from the left atrium (LA) if needed. The aim was to achieve &gt;30% increase in heart rate (HR) . The follow up consisted of regular visits and Holter ECG conducted every 3 months. Results A total number of 9 patients (age 52 ± 13) with vagally-mediated AF underwent RFCA of RAGP (mean RAGP RF time 147 ± 85, max power 34 ± 8W). The mean procedure time was 60 ± 29min. HR increase &gt;30% was achieved in 8 (89%) patients (pre-RF vs post-RF: 58 ± 8bpm vs 87 ± 12bpm, p = 0.00002) . Transseptal  to reach RAGP also from the LA was needed in 2 (22%) patients. There were no major complications during the procedures. The follow up lasted 6 ± 2 months. Antiarrhythmic drugs were discontinued in 8 (89%) patients. There was 1 (11%) AF recurrence in the patient in whom targeted HR acceleration during RFCA was not achieved. B-blockers were administered in  6 (67%) patients due to increased HR and such treatment was well tolerated by all. Conclusions Catheter ablation of RAGP without performing PVI is feasible and can be effective in majority of patients with vagally-mediated AF. Increased HR after such cardioneuroablation can be well controlled using b-blockers and is usually associated with mild symptoms. The role of cardioneuroablation for treatment of vagally-mediated AF needs to be determined in prospective trials. Abstract Figure. Cardioneuroablation in vagal AF


Circulation ◽  
2008 ◽  
Vol 118 (suppl_18) ◽  
Author(s):  
kiyotake Ishikawa ◽  
Yukihiko Yoshida ◽  
Sumio Morita ◽  
Kenji Furusawa ◽  
Noriyoshi Kanemura ◽  
...  

Background: Left atrium (LA) dilation plays an important role in development and persistence of atrial fibrillation (AF). Some cases show structural reverse remodeling of LA after catheter ablation of AF. The aim of this study was to assess the clinical significance of LA reverse remodeling. Method and Results: Echocardiographic data before and after ablation was obtained in 173 cases who underwent pulmonary vein isolation from January 2006 to April 2008 (74.0% men, 61.0±11 years old; paroxysmal AF 114, persistent AF 34, permanent AF 25). Mean atrial diameter before ablation was 39.0±6.1mm (paroxysmal 37.7±5.6mm, persistent 40.7±5.3mm, and permanent 43.0±6.8mm) and LA reverse remodeling was defined as 10% decrement of LA transverse diameter. Half of the cases were taking anti-arrhythmic drugs after ablation, and AF recurrence occurred in 16.8% (29/173) during mean follow up period of 8.5±6.3 months. Reverse remodeling of LA was seen in 34.1% (59/173) and AF recurrence rate in this group was 11.9% (7/59), whereas 19.3% (22/114) without reverse remodeling (P=0.29). However, limited in patients with LA diameter over 40mm (44.5%; 77/173), 3.2% (1/31) of AF recurrence was seen in those with reverse remodeling, while 21.7% (10/46) without reverse remodeling (P=0.04). LA reverse remodeling was observed significantly frequent in patients without history of hypertension(41.5% without hypertension vs 25.6% with hypertension, P=0.036). Conclusion: LA reverse remodeling after catheter ablation of AF in dilated LA patient is a simple and useful predictor for non-recurrence of AF. Hypertension could be a disturbance for LA reverse remodeling.


EP Europace ◽  
2020 ◽  
Vol 22 (Supplement_1) ◽  
Author(s):  
C Kettering

Abstract Background Catheter ablation has become the first line of therapy in patients with symptomatic, recurrent, drug-refractory atrial fibrillation. Circumferential pulmonary vein ablation is still the standard approach in these patients. However, the results are not very favourable and more complex ablation strategies are the subject of current controversy. Therefore, we have evaluated the effect of an additional linear lesion at the roof of the left atrium on the long-term outcome. Methods A total of 220 patients (114 men, 106 women; mean age 69 years (SD ± 14 years)) with symptomatic persistent atrial fibrillation underwent a circumferential pulmonary vein ablation procedure in combination with an additional linear lesion at the roof of the left atrium (group A). After discharge, patients were scheduled for repeated visits at the arrhythmia clinic at 1, 3, 6, 12, 24, 36, 48, 60, 72, 84, 96 and 102 months after the ablation procedure. The long-term follow-up data was compared to 220 patients who underwent circumferential pulmonary vein ablation without an additional linear lesion at the roof of the left atrium (group B). Results The ablation procedure could be performed as planned in all patients. Fifty-one out of 220 patients (23.2 %) in group A and 53 out of 220 patients (24.1 %) in group B experienced an arrhythmia recurrence within the first 3 months after ablation requiring an electrical cardioversion. At 102-month follow-up, analysis of a 168-hour ECG recording revealed no evidence for an arrhythmia recurrence in 125/220 patients (56.8 %) in group A and in 103/220 patients (46.8 %) in group B. In 66/220 patients (30.0 %) in group A and 59/220 patients (26.8 %) in group B, only short episodes of paroxysmal atrial fibrillation were documented. In 29 patients (13.2 %) in group A, a recurrence of persistent atrial fibrillation (&gt; 48 hours) was revealed by the long-term recordings (group B: 58 patients (26.4 %)). The lower arrhythmia recurrence rate in group A was partially due to a lower incidence of atypical atrial flutter after catheter ablation. The rate of repeat ablation procedures was significantly lower in group A than in group B. There were no major complications. Conclusions Catheter ablation of persistent atrial fibrillation comprising a circumferential pulmonary vein ablation and an additional linear lesion at the roof of the left atrium provides more favourable results than circumferential pulmonary vein ablation alone. The effect is more pronounced during long-term than during short-term follow-up.


EP Europace ◽  
2020 ◽  
Vol 22 (9) ◽  
pp. 1337-1344
Author(s):  
Matthias Daniel Zink ◽  
Winnie Chua ◽  
Stef Zeemering ◽  
Luigi di Biase ◽  
Bayes de Luna Antoni ◽  
...  

Abstract Aims Freedom from atrial fibrillation (AF) at 1 year can be achieved in 50–70% of patients undergoing catheter ablation. Recurrent AF early after ablation most commonly terminates spontaneously without further interventional treatment but is associated with later recurrent AF. The aim of this investigation is to identify clinical and procedural factors associated with recurrence of AF early after ablation. Methods and results We retrospectively analysed data for recurrence of AF within the first 3 months after catheter ablation from the randomized controlled AXAFA–AFNET 5 trial, which demonstrated that continuous anticoagulation with apixaban is as safe and as effective compared to vitamin K antagonists in 678 patients undergoing first AF ablation. The primary outcome of first recurrent AF within 90 days was observed in 163 (28%) patients, in which 78 (48%) patients experienced an event within the first 14 days post-ablation. After multivariable adjustment, a history of stroke/transient ischaemic attack [hazard ratio (HR) 1.54, 95% confidence interval (CI) 0.93–2.6; P = 0.11], coronary artery disease (HR 1.85, 95% CI 1.20–2.86; P = 0.005), cardioversion during ablation (HR 1.78, 95% CI 1.26–2.49; P = 0.001), and an age:sex interaction for older women (HR 1.01, 95% CI 1.00–1.01; P = 0.04) were associated with recurrent AF. The P-wave duration at follow-up was significantly longer for patients with AF recurrence (129 ± 31 ms vs. 122 ± 22 ms in patients without AF, P = 0.03). Conclusion Half of all early AF recurrences within the first 3 months post-ablation occurred within the first 14 days post-ablation. Vascular disease and cardioversion during the procedure are strong predictors of recurrent AF. P-wave duration at follow-up was longer in patients with recurrent AF. Trial registration Clinicaltrials.gov identifier NCT02227550


QJM ◽  
2020 ◽  
Vol 113 (Supplement_1) ◽  
Author(s):  
O H M A Riad ◽  
T Wong ◽  
A N Ali ◽  
M T Ibrahim ◽  
M A Abdelhamid ◽  
...  

Abstract Background Pulmonary vein isolation (PVI) has become the mainstay of catheter ablation of atrial fibrillation (AF). There are two commonly used methods to isolate the pulmonary veins, either point-by-point delivery of circumferential lesion sets around ipsilateral pulmonary veins using radiofrequency energy, or the application of the cryoballoon to the pulmonary vein antrum with occlusion of the vein ostium. The cryoballoon has proven to be a reliable alternative to radiofrequency ablation in acute and long-term freedom from AF. We describe our results using both modalities. Aim and Objectives to compare the safety and efficacy of cryoballoon (CB) ablation and radiofrequency (RF) ablation in treatment of paroxysmal atrial fibrillation. Patients and Methods Forty-four consecutive patients having paroxysmal AF underwent PVI using the second generation cryoballoon were compared to a retrospective cohort of 69 patients who had radiofrequency induced PVI, either by conventional RF catheter (n = 32), or a contact-force sensing-catheter (n = 37). The study took place at Ain Shams university hospitals and Royal Brompton & Harefield NHS trust. Patient data, procedural data and follow up data- at 3, 6 and 12 months- were collected and analysed. Recurrence was defined as documented AF or atrial arrhythmias with duration exceeding 30 seconds, either by 12 lead ECG or an ambulatory monitoring device. Results A total of 113 patients were studied. The mean age was 53.84 ± 15.01 for the CB group and 55.78 ± 14.84 for the RF group and females representing 40.9% vs 34.8% respectively. The mean procedural times in minutes were significantly less in the CB group (94.37 ± 39.32 vs 184.57 ± 88.19, p &lt; 0.0001), while the median fluoroscopy times were similar [30 (11.04 - 40) vs 37.25 (14.2 - 70), p = 0.172]. Procedural complications were comparable between the two groups (p = 0.06) with 1 patient (2.3%) having long term phrenic nerve paresis. At 1 year follow up, after an initial 90-day blanking period, recurrence rate of CB was similar to RF (27.3% vs 30.4% respectively, p = 0.719), the Kaplan Meier estimates of AF- free survival for a period of 1 year were comparable between both groups (log rank test, p = 0.606). Conclusion Cryoballoon is a feasible method for pulmonary vein isolation with similar success rates to radiofrequency ablation. Cryoballoon ablation is safe with shorter duration of the procedure.