scholarly journals Assessing the Suitability of Next-Generation Viral Outgrowth Assays to Measure Human Immunodeficiency Virus 1 Latent Reservoir Size

Author(s):  
Mars Stone ◽  
Daniel I S Rosenbloom ◽  
Peter Bacchetti ◽  
Xutao Deng ◽  
Melanie Dimapasoc ◽  
...  

Abstract Background Evaluations of human immunodeficiency virus (HIV) curative interventions require reliable and efficient quantification of replication-competent latent reservoirs. The “classic” quantitative viral outgrowth assay (QVOA) has been regarded as the reference standard, although prohibitively resource and labor intensive. We compared 6 “next-generation” viral outgrowth assays, using polymerase chain reaction or ultrasensitive p24 to assess their suitability as scalable proxies for QVOA. Methods Next-generation QVOAs were compared with classic QVOA using single leukapheresis-derived samples from 5 antiretroviral therapy–suppressed HIV-infected participants and 1 HIV-uninfected control; each laboratory tested blinded batches of 3 frozen and 1 fresh sample. Markov chain Monte Carlo methods estimated extra-Poisson variation at aliquot, batch, and laboratory levels. Models also estimated the effect of testing frozen versus fresh samples. Results Next-generation QVOAs had similar estimates of variation to QVOA. Assays with ultrasensitive readout reported higher infectious units per million values than classic QVOA. Within-batch testing had 2.5-fold extra-Poisson variation (95% credible interval [CI], 2.1–3.5-fold) for next-generation assays. Between-laboratory variation increased extra-Poisson variation to 3.4-fold (95% CI, 2.6–5.4-fold). Frozen storage did not substantially alter infectious units per million values (−18%; 95% CI, −52% to 39%). Conclusions The data offer cautious support for use of next-generation QVOAs as proxies for more laborious QVOA, while providing greater sensitivities and dynamic ranges. Measurement of latent reservoirs in eradication strategies would benefit from high throughput and scalable assays.

2015 ◽  
Vol 96 (3) ◽  
pp. 414-417
Author(s):  
T N Savchuk ◽  
Z K Burkitbaev ◽  
S A Abdrakhmanova ◽  
S V Skorikova ◽  
N S Kuz’min

Aim. To evaluate the effectiveness of NAT-screening (nucleic acid amplification technologies) for infections in blood donors in Kazakhstan. Methods. Statistical data of blood donors screening examinations in the Republic of Kazakhstan in 2012-2014 were evaluated. Results. In 2014, the number of examined donors increased by 3.4% compared with 2012. The number of deferrals due to positive screening results for serological markers decreased by 10.9%, while the share of such donors decreased by 13.8% [p <0.01; odds ratio (OR) - 0.86, 95% confidence interval (CI 95%) - 0.83-0.88); χ2=136.76]. In 2014, 100% of donations were screened using NAT-testing (312,510 donors). Most of the NAT-screening in Kazakhstan is performed using closed automated systems. In 2012, 1 Blood Center conducted a polymerase chain reaction screening by open circuit polymerase chain reaction systems, in 5 blood centers polymerase chain reaction was performed with manual sample preparation. In 2014, the number of deferrals due to positive NAT-testing results has increased by 44.3%, the share of such donors - by 38.7% (p <0.01; OR=1.39, 95% CI=1.15-1.67); χ2=11.82). Seronegative NAT-positive samples were discovered according to the results of discriminant test, including human immunodeficiency virus - 2 (0.8%) samples, hepatitis B virus -182 (73.4%), hepatitis C virus - 60 (24.2%), negative result - 4 (1.6%). Conclusion. The introduction of screening NAT-testing of donated blood prevented transfusion of blood infected with: human immunodeficiency virus - 1 in 150,000 donations, hepatitis B virus - 1 in 1.650 donations, hepatitis C virus - 1 in 5,000 donations.


Sign in / Sign up

Export Citation Format

Share Document