Monitoring urinary testosterone and epitestosterone levels, and their ratio, in Korean chemical castration subjects using liquid chromatography–tandem mass spectrometry

2019 ◽  
Vol 44 (2) ◽  
pp. 192-199 ◽  
Author(s):  
Juhyun Sim ◽  
Byungsuk Cho ◽  
Meejung Park ◽  
Jongsook Rhee ◽  
Sangwhan In ◽  
...  

Abstract In Europe, chemical castration has been adopted as a treatment for paraphilia since the 1930s. Among the various chemical castration agents, luteinizing hormone-releasing hormone (LHRH) agonists are now used widely because of their effectiveness and safety. In South Korea, a legislation of chemical castration to control the sexual impulses of sexual offenders was enforced in July 2011. Most of these subjects are treated with leuprorelin acetate, an LHRH agonist, for chemical castration. Despite this, there are few studies that address the long-term influence of LHRH agonists on testosterone (T) and epitestosterone (E) levels in chemical castration subjects. In order to analyze the urinary levels of T in chemical castration subjects, whose T levels are extremely low, we developed and validated an analytical method for the detection of both T and E in human urine using a liquid chromatography-tandem mass spectrometry (LC–MS/MS) system. The urine samples were hydrolyzed, extracted, and analyzed by LC–MS/MS with electrospray ionization in the positive-ion mode. The limits of detection were 0.02 ng/mL and the limits of quantitation were 0.05 ng/mL, which provided great sensitivity. The established method was applied to urine samples from chemical castration subjects and healthy male volunteers. The chemical castration subjects showed significantly lower urinary T levels than the control subjects. In addition, the urinary E levels were also lower in the chemical castration subjects; however, the T/E ratios were constant and did not show a notable decrease because of the simultaneous decrease in both urinary T and E. The urinary T levels and T/E ratio did not exceed the doping control criteria for exogenous T ingestion for any subject. This study shows the trend of urinary T and E levels in long-term treated chemical castration subjects by establishing a highly sensitive LC–MS/MS method, that provides useful information for monitoring chemical castration.

2014 ◽  
Vol 2014 ◽  
pp. 1-6 ◽  
Author(s):  
Caroline E. West ◽  
Blaine N. Rhodes

A viable, quick, and reliable method for determining urinary creatinine by liquid chromatography/tandem mass spectrometry (LC/MS/MS) was developed and used to evaluate spot urine samples collected for the Washington Environmental Biomonitoring Survey (WEBS): part of the Washington State Department of Health, Public Health Laboratories (PHL). 50 µL of urine was mixed with a 1 : 1 acetonitrile/water solution containing deuterated creatinine as the internal standard and then analyzed by LC/MS/MS. Utilizing electrospray ionization (ESI) in positive mode, the transition ions for creatinine and creatinine-d3were determined to be 114.0 to 44.1 (quantifier), 114.0 to 86.1 (qualifier), and 117.0 to 47.1 (creatinine-d3). The retention time for creatinine was 0.85 minutes. The linear calibration range was 20–4000 mg/L, with a limit of detection at 1.77 mg/L and a limit of quantitation at 5.91 mg/L. LC/MS/MS and the colorimetric Jaffé reaction were associated significantly (Pearsonr=0.9898andR2=0.9797,ρ≤0.0001). The LC/MS/MS method developed at the PHL to determine creatinine in the spot urine samples had shorter retention times, and was more sensitive, reliable, reproducible, and safer than other LC/MS/MS or commercial methods such as the Jaffé reaction or modified versions thereof.


Sign in / Sign up

Export Citation Format

Share Document