The Detection of Changes in Heparin Activity in the Rabbit: A Comparison of Anti-Xa Activity, Thrombelastography®, Activated Partial Thromboplastin Time, and Activated Coagulation Time

2002 ◽  
Vol 95 (6) ◽  
pp. 1503-1506 ◽  
Author(s):  
Vance G. Nielsen
1991 ◽  
Vol 66 (02) ◽  
pp. 213-217 ◽  
Author(s):  
Arthur P Bode ◽  
William J Castellani ◽  
Edna D Hodges ◽  
Susan Yelverton

SummaryThe effect of lysed platelets on the activated coagulation time (ACT) was studied in heparinized whole blood during titration with protamine. Frozen-thawed washed platelet suspension, or a chromatography fraction thereof, or autologous frozen-thawed platelet-rich plasma was added in various dilutions to freshly drawn blood anticoagulated with 3,000 USP units/1 heparin. After a 10 min incubation, the amount of protamine needed to restore the ACT to baseline ("protamine titration dose") was determined. We found that the protamine titration dose decreased in proportion to the amount of lysed platelet material added; expressed as a percentage of the total number of platelets present, each unit increase in lysed platelets produced a 1.7% ±0.8 (SD) reduction in the protamine dose needed to normalize the ACT. A heparin activity assay showed that this effect was not due to antiheparin activity of lysed platelets such as platelet factor 4 (PF4). Our data indicate that the procoagulant activity of platelet membranes reduced the sensitivity of the ACT to heparin. These findings suggest that membranous platelet microparticles may cause an inaccurate calculation, based on the ACT, of a protamine dose to reverse heparin anticoagulation in cardiopulmonary bypass procedures.


Blood ◽  
2004 ◽  
Vol 104 (12) ◽  
pp. 3631-3634 ◽  
Author(s):  
Armando Tripodi ◽  
Veena Chantarangkul ◽  
Ida Martinelli ◽  
Paolo Bucciarelli ◽  
Pier Mannuccio Mannucci

Hypercoagulability due to high coagulation factors XI, VIII, IX, II, and fibrinogen is recognized as a risk factor of venous thromboembolism (VTE). These factors are cumulatively explored by the activated partial thromboplastin time (APTT). To test the hypothesis that a short APTT increases the risk of VTE, a case-control study was carried out in 605 patients referred for thrombophilia testing after documented VTE and in 1290 controls. Median APTT ratio (coagulation time of test-to-reference plasma) values were 0.97 (range: 0.75-1.41) for patients and 1.00 (range: 0.72-1.33) for controls (P < .001). In patients who had an APTT ratio smaller than the fifth percentile of the distribution in controls, the odds ratio (OR) for VTE was 2.4 (95% confidence interval [CI]: 1.7-3.6) and was independent of inherited thrombophilic abnormalities. Further statistical analyses in 193 patients and 259 controls for whom factor VIII (FVIII) levels were available showed a decrease of the OR from 2.7 (95% CI: 1.4-5.3) to 2.1 (95% CI: 1.0-4.2), indicating that the risk was only partially mediated by high FVIII levels. In conclusion, hypercoagulability detected by a shortened APTT is independently associated with VTE. This inexpensive and simple test should be considered in the evaluation of the risk of VTE.


2018 ◽  
Vol 35 (7) ◽  
pp. 679-686 ◽  
Author(s):  
Clément Delmas ◽  
Aemilia Jacquemin ◽  
Fanny Vardon-Bounes ◽  
Bernard Georges ◽  
Felipe Guerrero ◽  
...  

Purpose: Extra Corporeal Membrane Oxygenation (ECMO) is used in cases of severe respiratory and/or circulatory failure over periods of several days to several weeks. Its circuitry requires a closely monitored anticoagulation therapy that is empirically supported by activated clotting time (ACT)—a method often associated with large inter- and intraindividual variability. We aimed to compare the measurement of heparin activity with ACT and the direct measurement of the heparin activity (anti-Xa) in a large ECMO population. Methods: All patients treated by venoarterial or venovenous ECMO in our intensive care unit between January 2014 and December 2015 were prospectively included. A concomitant measurement of the anti-Xa activity and ACT was performed on the same sample collected twice a day (morning–evening) for unfractionated heparin adaptation with an ACT target range of 180 to 220 seconds. Results: One hundred and nine patients (men 69.7%, median age 54 years) treated with ECMO (70.6% venoarterial) were included. Spearman analysis found no correlation between anti-Xa and ACT (ρ < 0.4) from day 1 and worsened over time. Kappa analysis showed no agreement between the respective target ranges of ACT and anti-Xa. Conclusions: We demonstrate that concomitant measurement of ACT and anti-Xa activity is irrelevant in ECMO patients. Since ACT is poorly correlated with heparin dosage, anti-Xa activity appears to be a more suitable assay for anticoagulation monitoring.


1990 ◽  
Vol 63 (01) ◽  
pp. 016-023 ◽  
Author(s):  
A M H P van den Bessekaar ◽  
J Meeuwisse-Braun ◽  
R M Bertina

SummaryFive different APTT reagents, two amidolytic anti-ITa assays, one amidoiytic anti-Xa assay, and one coagulometric anti-Xa/ anti-IIa assay were used to assess the effect of heparin in patients treated for venous thromboembolic disease. Good correlations were observed between lug-transformed APYE> determined with the various reagents (correlation coefficients: 0.92-0.96).Nevertheless there were important differences in the slopes of the lines of relationship between the APTT reagents.Good correlations were observed between the anti-Xa and anti-IIa assay results (correlation coefficients: 0.92-0.97). However, the amidolytic anti-Xa activity was significantly higher (p <0.001) than the two amidolytic anti-IIa activities. Less good correlations were observed between the log-transformed APTTs and the anti-Xa or anti-IIa activities (correlation coefficients: 0.64-0.78). The correlations were improved by transforming the APTT into APTT-ratio, i.e. the ratio of the patient’s APTT to the same patient’s APTT after removal of heparin from the plasma sample by means of ECTEOLA-cellulose treatment. The correlation coefficients of log (AFTT-ratio) with anti-Xa or anti-IIa ranged from 0.76 to 0.87.For both APTT and amidolytic heparin assay, the response to in vitro heparin was different from the response to ex vivo heparin.Therefore, equivalent therapeutic ranges should be assessed by using ex vivo samples rather than in vitro heparin. Because of the response differences between the APTT reagents, it is not adequate to define a therapeutic range for heparin therapy without specification of the reagent.


1994 ◽  
Vol 72 (05) ◽  
pp. 685-692 ◽  
Author(s):  
Michael T Nurmohamed ◽  
René J Berckmans ◽  
Willy M Morriën-Salomons ◽  
Fenny Berends ◽  
Daan W Hommes ◽  
...  

SummaryBackground. Recombinant hirudin (RH) is a new anticoagulant for prophylaxis and treatment of venous and arterial thrombosis. To which extent the activated partial thromboplastin time (APTT) is suitable for monitoring of RH has not been properly evaluated. Recently, a capillary whole blood device was developed for bed-side monitoring of the APTT and it was demonstrated that this device was suitable to monitor heparin therapy. However, monitoring of RH was not evaluated.Study Objectives. To evaluate in vitro and ex vivo the responsiveness and reproducibility for hirudin monitoring of the whole blood monitor and of plasma APTT assays, which were performed with several reagents and two conventional coagulometers.Results. Large interindividual differences in hirudin responsiveness were noted in both the in vitro and the ex vivo experiments. The relationship between the APTT, expressed as clotting time or ratio of initial and prolonged APTT, and the hirudin concentration was nonlinear. A 1.5-fold increase of the clotting times was obtained at 150-200 ng/ml plasma. However, only a 2-fold increase was obtained at hirudin levels varying from 300 ng to more than 750 ng RH/ml plasma regardless of the assays. The relationship linearized upon logarithmic conversion of the ratio and the hirudin concentration. Disregarding the interindividual differences, and presuming full linearity of the relationship, all combinations were equally responsive to hirudin.Conclusions. All assays were equally responsive to hirudin. Levels up to 300 ng/ml plasma can be reliably estimated with each assay. The manual device may be preferable in situations where rapid availability of test results is necessary.


1979 ◽  
Vol 42 (05) ◽  
pp. 1355-1367 ◽  
Author(s):  
C V Prowse ◽  
A Chirnside ◽  
R A Elton

SummaryVarious factor IX concentrates have been examined in a number of in vitro tests of thrombogenicity. The results suggest that some tests are superfluous as in concentrates with activity in any of these tests activation is revealed by a combination of the non-activated partial thromboplastin time, the thrombin (or Xa) generation time and factor VIII inhibitor bypassing activity tests. Assay of individual coagulant enzymes revealed that most concentrates contained more factor IXa than Xa. However only a small number of concentrates, chiefly those that had been purposefully activated, contained appreciable amounts of either enzyme.


Sign in / Sign up

Export Citation Format

Share Document