scholarly journals Use of a Mathematical Model to Predict Oxygen Transfer Rates in Hollow Fiber Membrane Oxygenators

ASAIO Journal ◽  
1994 ◽  
Vol 40 (4) ◽  
pp. 990-996 ◽  
Author(s):  
Steven N. Vaslef ◽  
Lyle F. Mockros ◽  
Robert W. Anderson ◽  
Ronald J. Leonard
ASAIO Journal ◽  
1994 ◽  
Vol 40 (4) ◽  
pp. 990-996 ◽  
Author(s):  
Steven N. Vaslef ◽  
Lyle F. Mockros ◽  
Robert W. Anderson ◽  
Ronald J. Leonard

2020 ◽  
Vol 2020 ◽  
pp. 1-6
Author(s):  
David M. Rubin ◽  
Neil T. Stacey ◽  
Tonderayi Matambo ◽  
Claudia Do Vale ◽  
Martin J. Sussman ◽  
...  

The COVID-19 pandemic has highlighted resource constraints in respiratory support. The oxygen transfer characteristics of a specific hollow fiber membrane dialyser was investigated with a view to repurposing the device as a low-cost, readily available blood oxygenator. Oxygen transfer in a low-flux hollow fiber dialyser with a polysulfone membrane was studied by passing first water and then blood through the dialyser in countercurrent to high-purity oxygen. Oxygen transfer rates of about 15% of the nominal 250 ml (STP)/min of a typical adult oxygen consumption rate were achieved for blood flow rates of 500 ml/min. Using two such dialysis devices in parallel could provide up to 30% of the nominal oxygen consumption. Specific hollow fiber dialysis devices operating with suitable pumps in a veno-venous access configuration could provide a cost-effective and readily available supplementation of respiratory support in the face of severe resource constraints.


1996 ◽  
Vol 19 (5) ◽  
pp. 291-293 ◽  
Author(s):  
D. Keh ◽  
M. Gerlach ◽  
I. Kürer ◽  
K.J. Falke ◽  
H. Gerlach

Bleeding during extracorporeal circulation (ECC) is often induced and/or aggravated by thrombocytopenia due to platelet-trapping in hollow fiber membrane oxygenators (HFMO). Nitric oxide (NO) has platelet anti-aggregating and dis-aggregating properties. In a paired system we tested whether gaseous NO, added to the gas compartment of one of two parallel running heparin-bonded HFMO attenuated platelet-trapping. Platelet consumption was markedly reduced in the NO-treated HFMO. These data strongly indicate that the application of gaseous NO could prove a new therapeutical approach to reduce bleeding during ECC, serving as a new way of preventing platelet loss, thus reducing the need for high systemic heparinization.


Perfusion ◽  
2006 ◽  
Vol 21 (6) ◽  
pp. 381-390 ◽  
Author(s):  
Akif Ündar ◽  
Bingyang Ji ◽  
Branka Lukic ◽  
Conrad M Zapanta ◽  
Allen R Kunselman ◽  
...  

Purpose: The objectives of this investigation were (1) to compare two hollow-fiber membrane oxygenators (Capiox Baby RX versus Lilliput 1-D901) in terms of pressure drops and surplus hemodynamic energy (SHE) during normothermic and hypothermic cardiopulmonary bypass (CPB) in a simulated neonatal model; and (2) to evaluate pulsatile and non-pulsatile perfusion modes for each oxygenator in terms of SHE levels. Methods: In a simulated patient, CPB was initiated at a constant pump flow rate of 500 mL/min. The circuit was primed with fresh bovine blood. After 5 min of normothermic CPB, the pseudo-patient was cooled down to 25°C for 10 min followed by 30 min of hypothermic CPB. The pseudo-patient then underwent 10 min of rewarming and 5 min of normothermic CPB. At each experimental site (pre- and post-oxygenator and pre-aortic cannula), SHE was calculated using the following formula {SHE (ergs/cm3) = 1332 [((ffpdt)/(ffdt))-mean arterial pressure]} (f = pump flow and p = pressure). A linear mixed-effects model that accounts for the correlation among repeated measurements was fit to the data to assess differences in SHE between oxygenators, pumps, and sites. Tukey’s multiple comparison procedure was used to adjust p-values for post-hoc pairwise comparisons. Results: The pressure drops in the Capiox group compared to the Lilliput group were significantly lower during hypothermic non-pulsatile (21.3∓0.5 versus 50.7∓0.9 mmHg, p B < 0.001) and pulsatile (22∓0.0 versus 53.3∓0.5 mmHg, p < 0.001) perfusion, respectively. Surplus hemodynamic energy levels were significantly higher in the pulsatile group compared to the non-pulsatile group, with Capiox (1655∓92 versus 10 008∓1370 ergs/cm3, p < 0.001) or Lilliput (1506∓112 versus 7531∓483 ergs/cm3, p < 0.001) oxygenators. During normothermic CPB, both oxygenators had patterns similar to those observed under hypothermic conditions. Conclusions: The Capiox oxygenator had a significantly lower pressure drop in both pulsatile and non-pulsatile perfusion modes. For each oxygenator, the SHE levels were significantly higher in the pulsatile mode.


2020 ◽  
Vol 20 (1) ◽  
pp. 78-85 ◽  
Author(s):  
Anxin Liu ◽  
Zhiquan Sun ◽  
Qier Liu ◽  
Ning Zhu ◽  
Shigang Wang

The advancement of cardiac surgery benefits from the continual technological progress of cardiopulmonary bypass (CPB). Every improvement in the CPB technology requires further clinical and laboratory tests to prove its safety and effectiveness before it can be widely used in clinical practice. In order to reduce the priming volume and eliminate a separate arterial filter in the CPB circuit, several manufacturers developed novel hollow-fiber membrane oxygenators with integrated arterial filters (IAF). Clinical and experimental studies demonstrated that an oxygenator with IAF could reduce total priming volume, blood donor exposure and gaseous microemboli delivery to the patient. It can be easily set up and managed, simplifying the CPB circuit without sacrificing safety. An oxygenator with IAF is expected to be more beneficial to the patients with low body weight and when using a minimized extracorporeal circulation system. The aim of this review manuscript was to discuss briefly the concept of integration, the current oxygenators with IAF, and the in-vitro / in-vivo performance of the oxygenators with IAF.


Sign in / Sign up

Export Citation Format

Share Document