Dislocation of the Distal Radioulnar Joint Associated with an Intraarticular Fracture of the Ulnar Head: Report of Two Cases

1998 ◽  
Vol 12 (1) ◽  
pp. 68-70 ◽  
Author(s):  
Yukihisa Tamura ◽  
Goro Inoue
2017 ◽  
Vol 42 (4) ◽  
pp. 415-421 ◽  
Author(s):  
B. D. Adams ◽  
J. L. Gaffey

A variety of surgical techniques are used to treat the arthritic distal radioulnar joint, which is influenced by aetiology and previous procedures. Four types of ulnar head arthroplasty exist: total ulnar head, partial ulnar head, unlinked total distal radioulnar joint, and linked distal radioulnar joint. Although long-term outcome studies are sparse, short-term clinical and biomechanical studies have shown encouraging results, leading to expanded indications. Based on our experience and a literature review, patients are advised that pain is improved but minor pain is common after strenuous activity. Ulnar neck resorption is common, however, implant loosening is rare. Sigmoid notch erosion is concerning, but appears to stabilize and not affect outcome. A partial ulnar head replacement that retains bony architecture and soft tissue restraints may have benefit over a total ulnar head in appropriate patients. If appropriate selection criteria are met, ulnar head replacement typically produces reliable results, with low revision.


2018 ◽  
Vol 07 (05) ◽  
pp. 375-381 ◽  
Author(s):  
Peter Tang ◽  
Keiji Fujio ◽  
Robert Strauch ◽  
Melvin Rosenwasser ◽  
Taiichi Matsumoto

Background Transosseous repair of foveal detachment of the triangular fibrocartilage complex (TFCC) is effective for distal radioulnar joint stabilization. However, studies of the optimal foveal and TFCC suture positions are scant. Purpose The purpose of this study was to clarify the optimal TFCC suture position and bone tunnels for transosseous foveal repair. Materials and Methods Seven cadavers were utilized. The TFCC was incised at the foveal insertion and sutured at six locations (TFCCs 1–6) using inelastic sutures. Six osseous tunnels were created in the fovea (foveae 1–6). Fovea 2 is located at the center of the circle formed by the ulnar head overlooking the distal end of the ulna (theoretical center of rotation); fovea 5 is located 2 mm ulnar to fovea 2. TFCC 5 is at the ulnar apex of the TFCC disc; TFCC 4 is 2 mm dorsal to TFCC 5. TFCC 1 to 6 sutures were then placed through each of the six osseous tunnels, resulting in 36 combinations, which were individually tested. The forearm was placed in five positions between supination and pronation, and the degree of suture displacement was measured. The position with the least displacement indicated the isometric point of the TFCC and fovea. Results The mean distance of suture displacement was 2.4 ± 1.6 mm. Fovea 2, combined with any TFCC location, (0.7 ± 0.6 mm) and fovea group 5, combined with TFCC 4 location (0.8 ± 0.8) or with TFCC 5 location (0.9 ± 0.6) had statistically shorter suture displacements than any other fovea groups. Conclusion For TFCC transosseous repair, osseous tunnel position was more important than TFCC suture location.


2021 ◽  
pp. 175319342110484
Author(s):  
Lea Estermann ◽  
Lisa Reissner ◽  
Andrea B. Rosskopf ◽  
Andreas Schweizer ◽  
Ladislav Nagy

This study aimed to analyse the clinical and radiological outcomes after ulnar head replacement and to compare partial and total ulnar head implants. Twenty-two patients with 23 implants were available with a mean follow-up time of 7 years (range 1.3 to 17) after distal radioulnar joint arthroplasty. At the final follow-up, patients had a low level of pain at rest and during effort, a median Disabilities of the Arm, Shoulder, and Hand (DASH) score of 12 and Patient-Rated Wrist Evaluation score of 12 with partial ulnar head implants, and scores of 20 and 22 in total ulnar head implants, respectively. While the range of motion in patients with partial ulnar head implants was slightly reduced in comparison with the preoperative condition and to the patients with total ulnar head implants, there was a tendency to a higher grip strength and rotational torque. Both types of prosthesis showed sigmoid notch resorptions and resorptions around the neck. We conclude that the results after partial ulnar head replacement do not significantly differ from the total ulnar head implants in many aspects. Level of evidence: III


Hand Surgery ◽  
2006 ◽  
Vol 11 (01n02) ◽  
pp. 15-19 ◽  
Author(s):  
K. N. Srikanth ◽  
S. A. Shahane ◽  
J. H. Stilwell

The pain of distal radioulnar arthrosis in rheumatoid patients is often due to disease largely confined to the radioulnar rather than the ulnocarpal articulation. This is a retrospective study of 14 patients (14 wrists) who underwent selective shaving of the radial articulation of the ulnar head leaving the ulnocarpal articulation intact. The ulnar head is reduced to the circumference of its shaft and a dorsal retinacular flap is interposed between it and the distal radius. Average age of the patients and follow-up were 63.5 years and 31 months, respectively. All patients had rheumatoid arthritis. Pain improved in 14 out of 15 wrists. Overall results were 67% good to excellent and 33% fair based on the modified Mayo's wrist score. This novel procedure for DRUJ arthrosis produces predictable pain relief in low demand rheumatoid patient.


2020 ◽  
Vol 45 (9) ◽  
pp. 923-930 ◽  
Author(s):  
Janni Kjærgaard Thillemann ◽  
Sepp De Raedt ◽  
Peter Bo Jørgensen ◽  
Lone Rømer ◽  
Torben Bæk Hansen ◽  
...  

Distal radioulnar joint instability is difficult to grade by clinical examination and interobserver reliability is low. This study used a new and precise radiostereometry method for measurement of distal radioulnar joint translation. Eight human donor arms were positioned in a custom-made fixture and a standardized piano key test was done with pressure on the ulnar head. Examination was done before and after dividing the styloid and foveal insertions of the triangular fibrocartilage complex. In the intact wrists, the piano key test induced a mean 1.36 mm translation of the ulnar head, which increased statistically significantly to 1.96 mm after a lesion of the styloid ligament insertion and to 2.3 mm after combined lesions of the styloid and foveal ligament insertions. This experimental cadaver study demonstrates a radiological method for precise quantification of distal radioulnar joint stability after different grades of triangular fibrocartilage complex injury.


2019 ◽  
Vol 24 (04) ◽  
pp. 447-451 ◽  
Author(s):  
Asami Abe ◽  
Hajime IshikawaKim

Background: The objective of this retrospective study was to evaluate the outcomes of ulnar stump stabilization after ulna head resection using the FCU tendon by investigating the rate of postoperative extensor tendon rupture and click on forearm rotation. Methods: Wrist synovectomy (distal radioulnar joint (DRUJ), radiocarpal and midcarpal joints) and ulnar head resection combined with ulnar stump stabilizing procedure were performed in 58 wrists of 53 patients with RA in our hospital. Before operation, the dorsal subluxation ratio (DSR) of the ulnar head was measured with a multi-slice computed tomography (CT) images. The stabilization of ulnar stump after head resection was performed by the value of the DSR or the instability before the operation. Results: There was neither extensor tendon rupture nor click on forearm rotation in all the patients. Smooth forearm rotation was achieved by ulnar head resection and stabilizing procedure for the ulnar stump. The active range of forearm supination and pronation increased significantly from 68° ± 23° (mean ± SD) to 80° ± 10°, and from 69° ± 17° to 74° ± 13°. The grip power increased from 117 ± 62 mmHg to 185 ± 55 mmHg. In the assessment using 3DCT, the preoperative DSR of 54% improved to 8% on the whole (n = 58). In the wrists with extensor tendon rupture (n = 36), the preoperative DSR of 58% improved to 12%. In the wrists without tendon rupture (n = 22), the preoperative DSR of 46% improved to 2%. Conclusions: The operative technique of ulnar stump stabilization using the FCU tendon was one of the suitable procedure to prevent complications after ulnar head resection.


Ultrasound ◽  
2021 ◽  
pp. 1742271X2110383
Author(s):  
Hiroshi Yuine ◽  
Yuichi Yoshii ◽  
Koichi Iwai ◽  
Tomoo Ishii ◽  
Hideki Shiraishi

Introduction In this study, we evaluated the differences and measurement accuracy in the force–displacement relationship of the distal radioulnar joint (DRUJ) between patients with triangular fibrocartilage complex (TFCC) injury and healthy controls using force-monitor ultrasonography. Methods This study included 11 TFCC injury patients and 22 healthy controls. We evaluated differences in the force–displacement relationship of the DRUJ in these patients using force-monitor ultrasonography. Cyclic compression was applied to the dorsal surface of the ulnar head. Distance between the dorsal surface of the distal radius and ulnar head at the DRUJ level was measured in the initial and pressed-down positions. Changes in radioulnar displacement, applied force, and displacement-to-force ratio were measured. Furthermore, we compared the parameters between the affected and unaffected wrists and between TFCC injury patients and controls. Results The radioulnar displacement and displacement-to-force ratio were significantly larger in the affected wrists than in the unaffected wrists ( P =  0.003 and P =  0.02). The affected/unaffected side ratio of radioulnar displacement and displacement-to-force ratio were significantly larger in the TFCC injury patients than in the controls ( P =  0.003 and P =  0.02). The area under the curve was 0.82 for the affected/unaffected ratio of the radioulnar displacement. The optimal cutoff value indicated by the receiver-operating characteristic curve for the affected/unaffected ratio of the radioulnar displacement was 1.71; the sensitivity and specificity were 82% and 86%, respectively. Conclusions Assessing the DRUJ instability with force-monitor ultrasonography may help identify TFCC-injured wrists.


2001 ◽  
Vol 26 (1) ◽  
pp. 41-44 ◽  
Author(s):  
L. R. SCHEKER ◽  
A. SEVERO

This prospective study describes the outcome of ulnar shortening performed on 32 wrists with early osteoarthritis of the distal radiounlar joint (DRUJ) in an attempt to change the contact area between the ulnar head and the radial sigmoid notch. By changing the contact area, we attempted to relieve pain, while maintaining the function of the DRUJ. The mean age of the patients was 34 years, and the mean follow-up was three years and two months. The wrists were graded by the patients’ self-assessment of satisfaction and by a clinical wrist rating that assessed pain, functional status, range of motion, and grip strength. In terms of self-assessment, 16/32 patients were very satisfied, with complete pain relief. Of the 32 patients, 26 said that they would have surgery again if circumstances were similar. The postoperative wrist ratings were 7/32 excellent, 11/32 good, 9/32 fair, 5/32 poor. The most frequent postoperative complaint was plate irritation.


Sign in / Sign up

Export Citation Format

Share Document