806 Virtual Fluoroscopy Improves Lumbar Pedicle Screw Placement Accuracy

Neurosurgery ◽  
2000 ◽  
Vol 47 (2) ◽  
pp. 530-530 ◽  
Author(s):  
Kevin T. Foley ◽  
Ramesh L. Sahjpaul ◽  
Gerald R. Rodts
2021 ◽  
Vol 12 ◽  
pp. 518
Author(s):  
Mohamed M. Arnaout ◽  
Magdy O. ElSheikh ◽  
Mansour A. Makia

Background: Transpedicular screws are extensively utilized in lumbar spine surgery. The placement of these screws is typically guided by anatomical landmarks and intraoperative fluoroscopy. Here, we utilized 2-week postoperative computed tomography (CT) studies to confirm the accuracy/inaccuracy of lumbar pedicle screw placement in 145 patients and correlated these findings with clinical outcomes. Methods: Over 6 months, we prospectively evaluated the location of 612 pedicle screws placed in 145 patients undergoing instrumented lumbar fusions addressing diverse pathology with instability. Routine anteroposterior and lateral plain radiographs were obtained 48 h after the surgery, while CT scans were obtained at 2 postoperative weeks (i.e., ideally these should have been performed intraoperatively or within 24–48 h of surgery). Results: Of the 612 screws, minor misplacement of screws (≤2 mm) was seen in 104 patients, moderate misplacement in 34 patients (2–4 mm), and severe misplacement in 7 patients (>4 mm). Notably, all the latter 7 (4.8% of the 145) patients required repeated operative intervention. Conclusion: Transpedicular screw insertion in the lumbar spine carries the risks of pedicle medial/lateral violation that is best confirmed on CT rather than X-rays/fluoroscopy alone. Here, we additional found 7 patients (4.8%) who with severe medial/lateral pedicle breach who warranting repeated operative intervention. In the future, CT studies should be performed intraoperatively or within 24–48 h of surgery to confirm the location of pedicle screws and rule in our out medial or lateral pedicle breaches.


2018 ◽  
Vol 46 (6) ◽  
pp. 2386-2397 ◽  
Author(s):  
Paerhati Rexiti ◽  
Yakufu Abulizi ◽  
Aikeremujiang Muheremu ◽  
Shuiquan Wang ◽  
Maierdan Maimaiti ◽  
...  

Objective To study the clinical application of lumbar isthmus parameters in guiding pedicle screw placement. Methods Lumbar isthmus parameters were measured in normal lumbar x-rays and cadaveric specimens from a Chinese Han population. Distance between the medial pedicle border and lateral isthmus border was recorded as a ‘D’ value and was compared between X-rays and cadavers. Orthopaedic surgeons estimated different distances (2–6 mm) and angles (5–20°), and bias ratios between estimated and real values were compared. Orthopaedic residents placed pedicle screws on cadaveric specimens before and after application of the ‘D’ value, and screw placement accuracy was compared. Results Except for L4 vertebrae, significant differences in the ‘D’ value were found between 25 cadaveric specimens and x-ray films from 120 patients. Distances and angles estimated by 40 surgeons were significantly different from all real values, except 2 mm distance. Accuracy of pedicle screw placement by six orthopaedic residents was significantly improved by applying the ‘D’ value. Conclusions Surgeon estimates of distance were more accurate than angle estimates. Addition of a ‘D’ value to conventional parameters may significantly improve pedicle screw placement accuracy in lumbar spine surgery.


Author(s):  
Tomohisa Inoue ◽  
Keiji Wada ◽  
Ayako Tominaga ◽  
Ryo Tamaki ◽  
Tomoya Hirota ◽  
...  

2010 ◽  
Vol 13 (4) ◽  
pp. 509-515 ◽  
Author(s):  
Cary Idler ◽  
Kevin W. Rolfe ◽  
Josef E. Gorek

Object This study was conducted to assess the in vivo safety and accuracy of percutaneous lumbar pedicle screw placement using the owl's-eye view of the pedicle axis and a new guidance technology system that facilitates orientation of the C-arm into the appropriate fluoroscopic view and the pedicle cannulation tool in the corresponding trajectory. Methods A total of 326 percutaneous pedicle screws were placed from L-3 to S-1 in 85 consecutive adult patients. Placement was performed using simple coaxial imaging of the pedicle with the owl's-eye fluoroscopic view. NeuroVision, a new guidance system using accelerometer technology, helped align the C-arm trajectory into the owl's-eye view and the cannulation tool in the same trajectory. Postoperative fine-cut CT scans were acquired to assess screw position. Medical records were reviewed for complications. Results Five of 326 screws breached a pedicle cortex—all breaches were less than 2 mm—for an accuracy rate of 98.47%. Five screws violated an adjacent facet joint. All were at the S-1 superior facet and included in a fusion. No screw violated an adjacent mobile facet or disc space. There were no cases of new or worsening neurological symptoms or deficits for an overall clinical accuracy of 100%. Conclusions The owl's-eye technique of coaxial pedicle imaging with the C-arm fluoroscopy, facilitated by NeuroVision, is a safe and accurate means by which to place percutaneous pedicle screws for degenerative conditions of the lumbar spine. This is the largest series reported to use the oblique or owl's-eye projection for percutaneous pedicle screw insertion. The accuracy of percutaneous screw insertion with this technique meets or exceeds that of other reported clinical series or techniques.


2015 ◽  
Vol 24 (5) ◽  
pp. 990-1004 ◽  
Author(s):  
Ahmed A. Aoude ◽  
Maryse Fortin ◽  
Rainer Figueiredo ◽  
Peter Jarzem ◽  
Jean Ouellet ◽  
...  

2015 ◽  
Vol 12 (4) ◽  
pp. 701-709
Author(s):  
Jeong-Yoon Park ◽  
Kyung-Hyun Kim ◽  
Sung-Uk Kuh ◽  
Dong-Kyu Chin ◽  
Keun-Su Kim ◽  
...  

2015 ◽  
Vol 7 (3) ◽  
pp. 213-221 ◽  
Author(s):  
Kevin Phan ◽  
Jarred Hogan ◽  
Monish Maharaj ◽  
Ralph J Mobbs

Sign in / Sign up

Export Citation Format

Share Document