In Older Patients, Reverse Total Shoulder Arthroplasty May Provide Better Outcomes Than Hemiarthroplasty

2021 ◽  
Vol 27 (4) ◽  
pp. 42-43
Arthroplasty ◽  
2021 ◽  
Vol 3 (1) ◽  
Author(s):  
Klaus Hanisch ◽  
Michael Boelstoft Holte ◽  
Inge Hvass ◽  
Niels Wedderkopp

Abstract Background Reverse total shoulder arthroplasty was originally designed for older patients with rotator cuff arthropathy and produces good results. The main objective of this retrospective study was to compare the patients younger than 65 years vs. the older patients in terms of the complications of reverse total shoulder arthroplasty and the functional recovery. Methods From January 2014 to January 2020, 566 patients who underwent the reverse total shoulder arthroplasty were divided into two groups (group A, ≥ 65 years, n = 506; group B, < 65 years, n = 60). The patients reported the quality of life using the patient-reported Western Ontario Osteoarthritis of the Shoulder index. The Constant score was obtained preoperatively and 3 months postoperatively. The complications and reoperations were compared. Statistical significance was set at P < 0.05. Results Clinically relevant improvements were found in group A and B. There was a multivariate statistically-significant but not clinically relevant difference in the change over time between group A and B. The mean 12-month Western Ontario Osteoarthritis of the Shoulder indexes were 58 in group B and 71 in group A. The mean Constant scores were 44 in group B vs. 43 in group A. Compared to group A, group B had a non-significant odds ratio of 1.9, which did not reach the clinically relevant Western Ontario Osteoarthritis of the Shoulder index of group A. Conclusion In patients younger than 65 years of age, RTSA seems to be a safe procedure in short term follow-up. After 1 year, we found no increased risk of complications, revision, or inferior outcomes compared to patients older than 65 years of age. Consequently, after one-year, RTSA provided clinically relevant improvements in the patients’ quality of life and shoulder strength regardless of age.


2021 ◽  
pp. 175857322110193
Author(s):  
Arjun K Reddy ◽  
Jake X Checketts ◽  
B Joshua Stephens ◽  
J Michael Anderson ◽  
Craig M Cooper ◽  
...  

Background Thus, the purpose of the present study was to (1) characterize common postoperative complications and (2) quantify the rates of revision in patients undergoing hemiarthroplasty to reverse total shoulder arthroplasty revisional surgery. We hypothesize that hardware loosenings will be the most common complication to occur in the sample, with the humeral component being the most common loosening. Methods This systematic review adhered to PRISMA reporting guideline. For our inclusion criteria, we included any study that contained intraoperative and/or postoperative complication data, and revision rates on patients who had undergone revision reverse total shoulder arthroplasty due to a failed hemiarthroplasty. Complications include neurologic injury, deep surgical site infections, hardware loosening/prosthetic instability, and postoperative fractures (acromion, glenoid, and humeral fractures). Results The study contained 22 studies that assessed complications from shoulders that had revision reverse total shoulder arthroplasty from a hemiarthroplasty, with a total sample of 925 shoulders. We found that the most common complication to occur was hardware loosenings (5.3%), and of the hardware loosenings, humeral loosenings (3.8%) were the most common. The revision rate was found to be 10.7%. Conclusion This systematic review found that revision reverse total shoulder arthroplasty for failed hemiarthroplasty has a high overall complication and reintervention rates, specifically for hardware loosening and revision rates.


2021 ◽  
pp. 175857322110329
Author(s):  
Therese E Parr ◽  
Jennifer K Anderson ◽  
Alan M. Marionneaux ◽  
John M Tokish ◽  
Stefan J Tolan ◽  
...  

Background In a reverse total shoulder arthroplasty, the altered glenohumeral joint center of rotation subjects the glenoid baseplate to increased shear forces and potential loosening. Methods This study examined glenoid baseplate micromotion and initial fixation strength with the application of direct shear force in a Sawbone model. The reverse total shoulder arthroplasty systems examined were the DJO Reverse® Shoulder Prosthesis, the Exactech Equinoxe® Reverse System, and the Tornier AequalisTM Reverse Shoulder Prosthesis. Specimens were cyclically tested with increasing shear loads until 150 µm of displacement between the implant and glenoid was achieved, and subsequently until failure, classified as either 1 cm of implant/glenoid displacement or fracture. Results The average load withstood for the 150 µm threshold for DJO, Tornier, and Exactech was 460 ± 88 N, 525 ± 100 N, and 585 ± 160 N, respectively. The average total load at device failure for DJO, Tornier, and Exactech was 980 ± 260 N, 1260 ± 120 N, and 1350 ± 230 N, respectively. Discussion The Exactech implant design trended toward requiring more load to induce micromotion at each threshold and to induce device failure, most commonly seen as inferior screw pull out. This study proposes design features that may enhance fixation and suggests little risk of initial micromotion or failure during initial post-operative recovery.


Sign in / Sign up

Export Citation Format

Share Document