RELIABILITY AND VALIDITY OF A SMARTPHONE HEART RATE APPLICATION FOR THE ASSESSMENT OF RESTING AND ELEVATED HEART RATE.

2014 ◽  
Vol 25 (4) ◽  
pp. 125
Author(s):  
Katy Mitchell ◽  
Megan Graff ◽  
James Simmons ◽  
Corbin Hedt
2016 ◽  
Vol 34 (5) ◽  
pp. 813-821 ◽  
Author(s):  
Paolo Palatini ◽  
Enrico Agabiti Rosei ◽  
Edoardo Casiglia ◽  
John Chalmers ◽  
Roberto Ferrari ◽  
...  

2020 ◽  
Author(s):  
Jiangang Sun ◽  
Yang Liu

BACKGROUND An increasing number of wrist-worn wearables are being examined in the context of health care. However, studies of their use during physical education (PE) lessons remain scarce. OBJECTIVE We aim to examine the reliability and validity of the Fizzo Smart Bracelet (Fizzo) in measuring heart rate (HR) in the laboratory and during PE lessons. METHODS In Study 1, 11 healthy subjects (median age 22.0 years, IQR 3.75 years) twice completed a test that involved running on a treadmill at 6 km/h for 12 minutes and 12 km/h for 5 minutes. During the test, participants wore two Fizzo devices, one each on their left and right wrists, to measure their HR. At the same time, the Polar Team2 Pro (Polar), which is worn on the chest, was used as the standard. In Study 2, we went to 10 schools and measured the HR of 24 students (median age 14.0 years, IQR 2.0 years) during PE lessons. During the PE lessons, each student wore a Polar device on their chest and a Fizzo on their right wrist to measure HR data. At the end of the PE lessons, the students and their teachers completed a questionnaire where they assessed the feasibility of Fizzo. The measurements taken by the left wrist Fizzo and the right wrist Fizzo were compared to estimate reliability, while the Fizzo measurements were compared to the Polar measurements to estimate validity. To measure reliability, intraclass correlation coefficients (ICC), mean difference (MD), standard error of measurement (SEM), and mean absolute percentage errors (MAPE) were used. To measure validity, ICC, limits of agreement (LOA), and MAPE were calculated and Bland-Altman plots were constructed. Percentage values were used to estimate the feasibility of Fizzo. RESULTS The Fizzo showed excellent reliability and validity in the laboratory and moderate validity in a PE lesson setting. In Study 1, reliability was excellent (ICC>0.97; MD<0.7; SEM<0.56; MAPE<1.45%). The validity as determined by comparing the left wrist Fizzo and right wrist Fizzo was excellent (ICC>0.98; MAPE<1.85%). Bland-Altman plots showed a strong correlation between left wrist Fizzo measurements (bias=0.48, LOA=–3.94 to 4.89 beats per minute) and right wrist Fizzo measurements (bias=0.56, LOA=–4.60 to 5.72 beats per minute). In Study 2, the validity of the Fizzo was lower compared to that found in Study 1 but still moderate (ICC>0.70; MAPE<9.0%). The Fizzo showed broader LOA in the Bland-Altman plots during the PE lessons (bias=–2.60, LOA=–38.89 to 33.69 beats per minute). Most participants considered the Fizzo very comfortable and easy to put on. All teachers thought the Fizzo was helpful. CONCLUSIONS When participants ran on a treadmill in the laboratory, both left and right wrist Fizzo measurements were accurate. The validity of the Fizzo was lower in PE lessons but still reached a moderate level. The Fizzo is feasible for use during PE lessons.


2017 ◽  
Author(s):  
Victoria Mazoteras Pardo ◽  
Marta E Losa Iglesias ◽  
José López Chicharro ◽  
Ricardo Becerro de Bengoa Vallejo

BACKGROUND Self-measurement of blood pressure is a priority strategy for managing blood pressure. OBJECTIVE The aim of this study was to evaluate the reliability and validity of blood pressure and heart rate following the European Society of Hypertension’s international validation protocol, as measured with the QardioArm, a fully automatic, noninvasive wireless blood pressure monitor and mobile app. METHODS A total of 100 healthy volunteers older than 25 years from the general population of Ciudad Real, Spain, participated in a test-retest validation study with two measurement sessions separated by 5 to 7 days. In each measurement session, seven systolic blood pressure, diastolic blood pressure, and heart rate assessments were taken, alternating between the two devices. The test device was the QardioArm and the previously validated criterion device was the Omron M3. Sessions took place at a single study site with an evaluation room that was maintained at an appropriate temperature and kept free from noises and distractions. RESULTS The QardioArm displayed very consistent readings both within and across sessions (intraclass correlation coefficients=0.80-0.95, standard errors of measurement=2.5-5.4). The QardioArm measurements corresponded closely to those from the criterion device (r>.96) and mean values for the two devices were nearly identical. The QardioArm easily passed all validation standards set by the European Society of Hypertension International Protocol. CONCLUSIONS The QardioArm mobile app has validity and it can be used free of major measurement error.


2018 ◽  
Vol 131 (12) ◽  
pp. 1473-1481 ◽  
Author(s):  
Phillip H. Lam ◽  
Neha Gupta ◽  
Daniel J. Dooley ◽  
Steven Singh ◽  
Prakash Deedwania ◽  
...  

2021 ◽  
Vol 14 (1) ◽  
pp. 18-26
Author(s):  
Martyna Waliczek ◽  
Piotr Rozentryt

Higher resting heart rate was shown to correlate with worse prognosis both in general population and in various disease groups. Scientific societies dealing with patients with hypertension propose assessment of resting heart rate as a standard risk factor. In patients with uncomplicated hypertension and elevated resting heart rate they propose use of cardioselective β1-adrenolytics. This decision should be preceded by careful examination of potential modified reasons. In the paper we express several concerns regarding standard provision of heart rate lowering drugs in particular clinical situations. The algorithm showing proposed steps in assessment of elevated heart rate is provided.


Author(s):  
Lindsey Aurora ◽  
Paul Nona ◽  
Karthikeyan Ananthasubramaniam

1956 ◽  
Vol 184 (2) ◽  
pp. 275-281 ◽  
Author(s):  
Eugene W. Brickner ◽  
E. Grant Dowds ◽  
Bruce Willitts ◽  
Ewald E. Selkurt

The influence of hypercapnia on mesenteric blood flow was studied in dogs subjected to progressive increments in CO2 content of inspired air produced by rebreathing from a large spirometer. Oxygen content was maintained above 21 volumes %. Although some animals showed an initial tendency for mesenteric blood flow to decrease and arterial pressure to increase in the range 0–5 volumes % of CO2, the usual hemodynamic change in the range 5–16 volumes % was an increase in mesenteric blood flow resulting from decrease in intestinal vascular resistance, accompanied by a decline in arterial pressure. Portal venous pressure was progressively elevated. Heart rate slowed in association with an increase in pulse pressure. The observations suggest that in higher ranges of hypercapnia, CO2 has a direct dilating action on the mesenteric vasculature.