scholarly journals Sound Quality Ratings of Amplified Speech and Music Using a Direct Drive Hearing Aid

2020 ◽  
Vol Publish Ahead of Print ◽  
Author(s):  
Jonathan Vaisberg ◽  
Paula Folkeard ◽  
Suzanne Levy ◽  
Drew Dundas ◽  
Sumit Agrawal ◽  
...  
2020 ◽  
Vol 63 (12) ◽  
pp. 4300-4313
Author(s):  
Emily M. H. Lundberg ◽  
Song Hui Chon ◽  
James M. Kates ◽  
Melinda C. Anderson ◽  
Kathryn H. Arehart

Purpose The overall goal of the current study was to determine whether noise type plays a role in perceptual quality ratings. We compared quality ratings using various noise types and signal-to-noise ratio (SNR) ranges using hearing aid simulations to consider the effects of hearing aid processing features. Method Ten older adults with bilateral mild to moderately severe sensorineural hearing loss rated the sound quality of sentences processed through a hearing aid simulation and presented in the presence of five different noise types (six-talker babble, three-talker conversation, street traffic, kitchen, and fast-food restaurant) at four SNRs (3, 8, 12, and 20 dB). Results Everyday noise types differentially affected sound quality ratings even when presented at the same SNR: Kitchen and three-talker noises were rated significantly higher than restaurant, traffic, and multitalker babble, which were not different from each other. The effects of noise type were most pronounced at poorer SNRs. Conclusions The findings of this study showed that noise types differentially affected sound quality ratings. The differences we observed were consistent with the acoustic characteristics of the noise types. Noise types having lower envelope fluctuations yielded lower quality ratings than noise types characterized by sporadic high-intensity events at the same SNR.


2021 ◽  
Vol 25 ◽  
pp. 233121652199761
Author(s):  
Yuan Chen ◽  
Lena L. N. Wong ◽  
Volker Kuehnel ◽  
Jinyu Qian ◽  
Solveig Christina Voss ◽  
...  

The aim of this study was to evaluate the efficacy of dual compression for Mandarin-speaking hearing aid users. Dual compression combines fast and slow compressors operating simultaneously across all frequency channels. The study participants were 31 hearing aid users with symmetrical moderate-to-severe hearing loss, with a mean age of 67 years. A new pair of 20-channel behind-the-ear hearing aids (i.e., Phonak Bolero B90-P) was used during the testing. The results revealed a significant improvement in speech reception thresholds in noise when switching from fast-acting compression to dual compression. The sound quality ratings revealed that most listeners preferred dual compression to fast-acting compression for listening effort, listening comfort, speech clarity, and overall sound quality at +4 dB signal-to-noise ratio. These results are consistent with predictions based on the theoretical understanding of dual and fast-acting compression. However, whether these results can be generalized to other languages or other dual compression systems should be verified by future studies.


2020 ◽  
Vol 31 (08) ◽  
pp. 590-598
Author(s):  
Li Xu ◽  
Solveig C. Voss ◽  
Jing Yang ◽  
Xianhui Wang ◽  
Qian Lu ◽  
...  

Abstract Background Mandarin Chinese has a rich repertoire of high-frequency speech sounds. This may pose a remarkable challenge to hearing-impaired listeners who speak Mandarin Chinese because of their high-frequency sloping hearing loss. An adaptive nonlinear frequency compression (adaptive NLFC) algorithm has been implemented in contemporary hearing aids to alleviate the problem. Purpose The present study examined the performance of speech perception and sound-quality rating in Mandarin-speaking hearing-impaired listeners using hearing aids fitted with adaptive NLFC (i.e., SoundRecover2 or SR2) at different parameter settings. Research Design Hearing-impaired listeners' phoneme detection thresholds, speech reception thresholds, and sound-quality ratings were collected with various SR2 settings. Study Sample The participants included 15 Mandarin-speaking adults aged 32 to 84 years old who had symmetric sloping severe-to-profound sensorineural hearing loss. Intervention The participants were fitted bilaterally with Phonak Naida V90-SP hearing aids. Data Collection and Analysis The outcome measures included phoneme detection threshold using the Mandarin Phonak Phoneme Perception test, speech reception threshold using the Mandarin hearing in noise test (M-HINT), and sound-quality ratings on human speech in quiet and noise, bird chirps, and music in quiet. For each test, five experimental settings were applied and compared: SR2-off, SR2-weak, SR2-default, SR2-strong 1, and SR2-strong 2. Results The results showed that listeners performed significantly better with SR2-strong 1 and SR2-strong 2 settings than with SR2-off or SR2-weak settings for speech reception threshold and phoneme detection threshold. However, no significant improvement was observed in sound-quality ratings among different settings. Conclusions These preliminary findings suggested that the adaptive NLFC algorithm provides perceptual benefit to Mandarin-speaking people with severe-to-profound hearing loss.


2012 ◽  
Vol 23 (08) ◽  
pp. 606-615 ◽  
Author(s):  
HaiHong Liu ◽  
Hua Zhang ◽  
Ruth A. Bentler ◽  
Demin Han ◽  
Luo Zhang

Background: Transient noise can be disruptive for people wearing hearing aids. Ideally, the transient noise should be detected and controlled by the signal processor without disrupting speech and other intended input signals. A technology for detecting and controlling transient noises in hearing aids was evaluated in this study. Purpose: The purpose of this study was to evaluate the effectiveness of a transient noise reduction strategy on various transient noises and to determine whether the strategy has a negative impact on sound quality of intended speech inputs. Research Design: This was a quasi-experimental study. The study involved 24 hearing aid users. Each participant was asked to rate the parameters of speech clarity, transient noise loudness, and overall impression for speech stimuli under the algorithm-on and algorithm-off conditions. During the evaluation, three types of stimuli were used: transient noises, speech, and background noises. The transient noises included “knife on a ceramic board,” “mug on a tabletop,” “office door slamming,” “car door slamming,” and “pen tapping on countertop.” The speech sentences used for the test were presented by a male speaker in Mandarin. The background noises included “party noise” and “traffic noise.” All of these sounds were combined into five listening situations: (1) speech only, (2) transient noise only, (3) speech and transient noise, (4) background noise and transient noise, and (5) speech and background noise and transient noise. Results: There was no significant difference on the ratings of speech clarity between the algorithm-on and algorithm-off (t-test, p = 0.103). Further analysis revealed that speech clarity was significant better at 70 dB SLP than 55 dB SPL (p < 0.001). For transient noise loudness: under the algorithm-off condition, the percentages of subjects rating the transient noise to be somewhat soft, appropriate, somewhat loud, and too loud were 0.2, 47.1, 29.6, and 23.1%, respectively. The corresponding percentages under the algorithm-on were 3.0, 72.6, 22.9, and 1.4%, respectively. A significant difference on the ratings of the transient noise loudness was found between the algorithm-on and algorithm-off (t-test, p < 0.001). For overall impression for speech stimuli: under the algorithm-off condition, the percentage of subjects rating the algorithm to be not helpful at all, somewhat helpful, helpful, and very helpful for speech stimuli were 36.5, 20.8, 33.9, and 8.9%, respectively. Under the algorithm-on condition, the corresponding percentages were 35.0, 19.3, 30.7, and 15.0%, respectively. Statistical analysis revealed there was a significant difference on the ratings of overall impression on speech stimuli. The ratings under the algorithm-on condition were significantly more helpful for speech understanding than the ratings under algorithm-off (t-test, p < 0.001). Conclusions: The transient noise reduction strategy appropriately controlled the loudness for most of the transient noises and did not affect the sound quality, which could be beneficial to hearing aid wearers.


2017 ◽  
Vol 28 (09) ◽  
pp. 810-822 ◽  
Author(s):  
Benjamin J. Kirby ◽  
Judy G. Kopun ◽  
Meredith Spratford ◽  
Clairissa M. Mollak ◽  
Marc A. Brennan ◽  
...  

AbstractSloping hearing loss imposes limits on audibility for high-frequency sounds in many hearing aid users. Signal processing algorithms that shift high-frequency sounds to lower frequencies have been introduced in hearing aids to address this challenge by improving audibility of high-frequency sounds.This study examined speech perception performance, listening effort, and subjective sound quality ratings with conventional hearing aid processing and a new frequency-lowering signal processing strategy called frequency composition (FC) in adults and children.Participants wore the study hearing aids in two signal processing conditions (conventional processing versus FC) at an initial laboratory visit and subsequently at home during two approximately six-week long trials, with the order of conditions counterbalanced across individuals in a double-blind paradigm.Children (N = 12, 7 females, mean age in years = 12.0, SD = 3.0) and adults (N = 12, 6 females, mean age in years = 56.2, SD = 17.6) with bilateral sensorineural hearing loss who were full-time hearing aid users.Individual performance with each type of processing was assessed using speech perception tasks, a measure of listening effort, and subjective sound quality surveys at an initial visit. At the conclusion of each subsequent at-home trial, participants were retested in the laboratory. Linear mixed effects analyses were completed for each outcome measure with signal processing condition, age group, visit (prehome versus posthome trial), and measures of aided audibility as predictors.Overall, there were few significant differences in speech perception, listening effort, or subjective sound quality between FC and conventional processing, effects of listener age, or longitudinal changes in performance. Listeners preferred FC to conventional processing on one of six subjective sound quality metrics. Better speech perception performance was consistently related to higher aided audibility.These results indicate that when high-frequency speech sounds are made audible with conventional processing, speech recognition ability and listening effort are similar between conventional processing and FC. Despite the lack of benefit to speech perception, some listeners still preferred FC, suggesting that qualitative measures should be considered when evaluating candidacy for this signal processing strategy.


2021 ◽  
Vol 17 (2) ◽  
pp. 198-205
Author(s):  
Leehwa Park ◽  
Soo Hee Oh

Purpose: Recent bimodal studies identified a lack of bimodal evaluation and fitting protocols to improve bimodal benefits. The purpose of this study is to measure bimodal benefits in speech and sound quality recognition and identify bimodal fitting issues with adult cochlear implant listeners to establish bimodal fitting guidelines and evaluation protocol.Methods: A total of 20 adult cochlear implant users were participated in this study. The experimental procedures included basic evaluation, hearing aid evaluation, and bimodal benefits evaluation. In order to evaluate bimodal benefits, speech and sound quality recognition tests were performed. Matrix sentences in quiet and noise (5 and 10 dB sound pressure level), consonant-vowel-consonant words, and story comprehension tasks were provided. Participants judged sound qualities for six sound quality dimensions and a tester performed real ear measurements to verify hearing aid gains.Results: Results showed that bimodal listeners had some bimodal benefits in the sentence and monosyllabic word recognition in quiet. The benefits of sound quality judgments were also observed for six sound quality dimensions. Bimodal cochlear implant listeners of this study demonstrated less real-ear insertion gains than target gains across test frequencies.Conclusion: Speech and sound quality recognition tests are useful tools to measure bimodal benefits. Additional care for bimodal listeners is needed to optimize bimodal fitting and improve the quality of bimodal hearing aid fitting services.


2020 ◽  
Author(s):  
Solveig Christina Voss ◽  
M Kathleen Pichora-Fuller ◽  
Ieda Ishida ◽  
April Emily Pereira ◽  
Julia Seiter ◽  
...  

Background:Conventional directional hearing aid microphone technology would obstruct listening intentions in walking situations when the talker and listener walk side by side. The purpose of the current study was to evaluate hearing aids that use a motion sensor to address listening needs during walking. Methods:Participants were 22 older adults with moderate-to-severe hearing loss and experience using hearing aids. Each participant completed two walks in randomized order, one walk with each of two hearing aid programs: 1) a conventional classifier that activated an adaptive, multiband beamformer in loud environments and 2) a classifier that additionally utilized motion-based beamformer steering. Participants walked along a pre-defined track and completed tasks assessing speech understanding and environmental awareness. Results:Most participants preferred the motion-based beamformer steering for speech understanding, environmental awareness, overall listening, and sound quality (p&lt;0.05). Additionally, measures of speech understanding (p&lt;0.01) and localization of sound stimuli (p&lt;0.05) were significantly better with the motion-based beamformer steering than with the conventional classifier.Conclusion:The results suggest that hearing aid users benefit from classifiers that use motion sensor input to adapt the signal processing according to the user’s activity. The real-world setup of this study had limitations but also high ecological validity.


1996 ◽  
Vol 100 (4) ◽  
pp. 2817-2817
Author(s):  
Eva Chiu ◽  
Donald G. Jamieson ◽  
Vijay Parsa ◽  
Leonard Cornelisse

Sign in / Sign up

Export Citation Format

Share Document