Comparison of Methods to Measure Heart Size Using Noncontrast-Enhanced Computed Tomography

2008 ◽  
Vol 32 (6) ◽  
pp. 934-941 ◽  
Author(s):  
Kurt R. Daniel ◽  
Alain G. Bertoni ◽  
Jingzhong Ding ◽  
Sara Johnston ◽  
Matthew J. Budoff ◽  
...  
Author(s):  
Eric T. Hostnik ◽  
Valerie J. Parker ◽  
John M. Cullen

ABSTRACT A 9 mo old female intact golden retriever presented for evaluation of chronic lethargy and decreased appetite. The serum biochemistry profile revealed increased liver enzymes consistent with a mixed hepatocellular and cholestatic pattern. A multiphase computed tomography angiography was performed to evaluate for a portosystemic shunt. Numerous hyperattenuating nodules were identified throughout the liver on the noncontrast-enhanced series. Histologic evaluation of percutaneous needle biopsy samples of a liver nodule showed a rare form of hepatitis called lobular dissecting hepatitis. Lobular dissecting hepatitis should be considered as a differential in young dogs with precontrast hyperattenuating hepatic nodules on noncontrast-enhanced computed tomography.


2016 ◽  
Vol 19 (1) ◽  
pp. 028
Author(s):  
Shengjun Wu ◽  
Peng Teng ◽  
Yiming Ni ◽  
Renyuan Li

Coronary sinus aneurysm (CSA) is an extremely rare entity. Herein, we present an unusual case of an 18-year-old symptomatic female patient with a giant CSA. Secondary vena cava aneurysms were also manifested. The final diagnosis was confirmed by enhanced computed tomography (CT) and cardiac catheterization. As far as we know, it is the first case that such a giant CSA coexists with secondary vena cava aneurysms. Considering the complexity of postoperative reconstruction, we believe that heart transplantation may be the optimal way for treatment. The patient received anticoagulant due to the superior vena cava (SVC) thrombosis while waiting for a donor.


2011 ◽  
Vol 46 (9) ◽  
pp. 586-593 ◽  
Author(s):  
Scott M. Thompson ◽  
Juan C. Ramirez-Giraldo ◽  
Bruce Knudsen ◽  
Joseph P. Grande ◽  
Jodie A. Christner ◽  
...  

Author(s):  
Frederik Pauwels ◽  
Angela Hartmann ◽  
John Al-Alawneh ◽  
Paul Wightman ◽  
Jimmy Saunders

2021 ◽  
Vol 22 (Supplement_1) ◽  
Author(s):  
P Poskaite ◽  
M Pamminger ◽  
C Kranewitter ◽  
C Kremser ◽  
M Reindl ◽  
...  

Abstract Funding Acknowledgements Type of funding sources: None. Background The natural history of thoracic aortic aneurysm (TAA) is one of progressive expansion. Asymptomatic patients who do not meet criteria for repair require conservative management including ongoing aneurysm surveillance, mostly carried out by contrast-enhanced computed tomography angiography (CTA). Purpose To prospectively compare image quality and reliability of a prototype non-contrast, self-navigated 3D whole-heart magnetic resonance angiography (MRA) with contrast-enhanced computed tomography angiography (CTA) for sizing of thoracic aortic aneurysm (TAA). Methods Self-navigated 3D whole-heart 1.5 T MRA was performed in 20 patients (aged 67 ± 8.6 years, 75% male) for sizing of TAA; a subgroup of 18 (90%) patients underwent additional contrast-enhanced CTA on the same day. Subjective image quality was scored according to a 4-point Likert scale and ratings between observers were compared by Cohen’s Kappa statistics. Continuous MRA and CTA measurements were analyzed with regression and Bland-Altman analysis. Results Overall subjective image quality as rated by two observers was 1 [interquartile range (IQR) 1-2] for self-navigated MRA and 1.5 [IQR 1-2] for CTA (p = 0.717). For MRA a perfect inter-observer agreement was found for presence of artefacts and subjective image sharpness (κ=1). Subjective signal inhomogeneity correlated highly with objectively quantified inhomogeneity of the blood pool signal (r = 0.78-0.824, all p <0.0001). Maximum diameters of TAA as measured by self-navigated MRA and CTA showed excellent correlation (r = 0.997, p < 0.0001) without significant inter-method bias (bias -0.0278, lower and upper limit of agreement -0.74 and 0.68, p = 0.749). Inter- and intraobserver correlation of aortic aneurysm as measured by MRA was excellent (r = 0.963 and 0.967, respectively) without significant bias (all p ≤ 0.05). Conclusion Self-navigated 3D whole-heart MRA enables reliable contrast- and radiation free aortic dilation surveillance without significant difference to standardized CTA while providing predictable acquisition time and by offering excellent image quality. Abstract Figure.


Sign in / Sign up

Export Citation Format

Share Document