scholarly journals Comparison of SARS-CoV-2 viral load in saliva samples in symptomatic and asymptomatic cases

Author(s):  
Anuja Bhatta ◽  
Rebecca Henkhaus ◽  
Heather L. Fehling

AbstractSARS-CoV-2 infections can be symptomatic as well as asymptomatic. In this study, we analyzed 460,814 saliva samples collected from July 2020 to January 2021 for a SARS-CoV-2-specific gene target using the FDA EUA test, CRL Rapid Response™, based on reverse transcription polymerase chain reaction (RT-PCR). We measured SARS-CoV-2 viral loads using cycle threshold (Ct) values. A total of 17,813 samples tested positive for COVID-19 using self-collected saliva samples. The Ct values ranged from 11 to 40, 91.3% distributed between 22 to 38 Ct. We then compared Ct values for symptomatic and asymptomatic cases for all positive saliva samples. A total of 8,706 cases were symptomatic with an average Ct value of 29.24, and 9,107 cases were asymptomatic with an average Ct value of 30.99. Hence, SARS-CoV-2 viral loads (Ct) in saliva samples for both symptomatic and asymptomatic cases are similar.

Author(s):  
Rajeev Kumar Jain ◽  
Nagaraj Perumal ◽  
Rakesh Shrivastava ◽  
Kamlesh Kumar Ahirwar ◽  
Jaya Lalwani ◽  
...  

Introduction: The whole world is facing an ongoing global health emergency of COVID-19 disease caused by the Severe Acute Respiratory Syndrome Coronavirus-2 (SARS-CoV-2). Real-Time Reverse Transcription-Polymerase Chain Reaction (RT-PCR) is a gold standard in the detection of SARS-CoV-2 infection. Presently, many single tube multiple gene target RT-PCR kits have been developed and are commercially available for Coronavirus Disease 2019 (COVID-19) diagnosis. Aim: To evaluate the performance of seven COVID-19 RT-PCR kits (DiagSure, Meril, VIRALDTECT II, TruPCR, Q-line, Allplex and TaqPath) which are commercially available for COVID-19 RT-PCR diagnosis. Materials and Methods: This observational study was conductedat the State Virology Laboratory (SVL), Gandhi Medical College, Bhopal, Madhya Pradesh, India. Seven commercially available kits have been evaluated on the basis of: (i) number of SARS-CoV-2 specific gene target; (ii) human housekeeping genes as internal control; (iii) RT-PCR run time; and (iv) kit performances to correctly detect SARS-CoV-2 positive and negative RNA samples. A total of 50 RNA samples (left over RNA) were included, master mix preparation, template addition and RT-PCR test has been performed according to kits literature. At the end of PCR run, mean and standard deviation of obtained cut-off of all kits were calculated using Microsoft Excel. Results: All seven RT-PCR kits performed satisfactory regarding the reproducibility and they could correctly identify 30 positive and 20 negative RNA samples. RNA samples (group C) having low viral loads with a high Cycle threshold (Ct) value (>30) were also detected by all these seven kits. Obtained Ct values of each group was in parallel range in comparison with the initial testing Ct values. Kits were found to be superior which contains primers and probes for three SARS-CoV-2 specific gene targets, have human housekeeping gene as internal control and taking less time to complete RT-PCR. Conclusion: All seven COVID-19 RT-PCR kits included in this study demonstrated satisfactory performance and can be used for the routine molecular diagnosis of COVID-19 disease.


2006 ◽  
Vol 175 (4S) ◽  
pp. 485-486
Author(s):  
Sabarinath B. Nair ◽  
Christodoulos Pipinikas ◽  
Roger Kirby ◽  
Nick Carter ◽  
Christiane Fenske

1990 ◽  
Vol 258 (5) ◽  
pp. F1470-F1474 ◽  
Author(s):  
T. Moriyama ◽  
H. R. Murphy ◽  
B. M. Martin ◽  
A. Garcia-Perez

We have developed a procedure to detect specific mRNAs in single renal nephron segments. This approach combines microdissection, reverse transcription (RT) of the target mRNA, and amplification of the resulting cDNA using the polymerase chain reaction (PCR). After microdissection, the sample is placed in a tube where it is permeabilized and where all reactions are performed directly without the need for isolation of the RNA. Our model target was the mRNA for aldose reductase. This enzyme catalyzes the conversion of glucose to sorbitol. Its expression is modulated by changes in extracellular osmolality in the renal medulla. RT-PCR of inner medullary collecting duct (1 mm) and glomeruli (6-10) yielded a product of the predicted length (670 base pairs) defined by the PCR primers. Its identity was confirmed by a specific oligonucleotide probe that differed from the primers. RT-PCR of proximal tubules (1 mm) resulted in no aldose reductase-specific amplification product. RT-PCR is generally applicable for measuring specific gene expression in single nephron segments or small numbers of cultured cells. Utility, limitations, and refinements of this approach are discussed.


2003 ◽  
Vol 15 (2) ◽  
pp. 99 ◽  
Author(s):  
Paisan Tienthai ◽  
Naoko Kimura ◽  
Paraskevi Heldin ◽  
Eimei Sato ◽  
Heriberto Rodriguez-Martinez

Hyaluronan (HA) has been related to fertilization and embryo development in the pig. Furthermore, HA is present in pig oviduct fluid and the lining epithelium, particularly of the pre-ovulatory sperm reservoir. Because the mechanisms that regulate HA synthesis have not yet been clarified, semiquantitative reverse transcription-polymerase chain reaction (RT-PCR) was conducted to assess the expression of mRNAs of two HA-synthesizing enzymes (has2 and has3) in the oviduct epithelium (uterotubal junction, isthmus, ampullary–isthmic junction and ampulla segments) of non-inseminated (control) and inseminated (treatment) sows at pre-, peri- and post-ovulatory oestrus. Only has3 mRNA was detected; it was present in all tubal segments of both control and treatment samples. The level of has3 expression did not vary significantly between non-inseminated and inseminated specimens, but there was a tendency (NS) for increased mean values during the peri- and post-ovulatory stages compared with pre-ovulation. It is concluded that has3 is expressed by the porcine endosalpinx epithelium and the levels of expression do not vary during the critical periods of sperm transport and fertilization, despite fluctuating levels of HA in the tubal fluid at corresponding periods.


BMJ ◽  
2021 ◽  
pp. n1637 ◽  
Author(s):  
Marta García-Fiñana ◽  
David M Hughes ◽  
Christopher P Cheyne ◽  
Girvan Burnside ◽  
Mark Stockbridge ◽  
...  

Abstract Objective To assess the performance of the SARS-CoV-2 antigen rapid lateral flow test (LFT) versus polymerase chain reaction testing in the asymptomatic general population attending testing centres. Design Observational cohort study. Setting Community LFT pilot at covid-19 testing sites in Liverpool, UK. Participants 5869 asymptomatic adults (≥18 years) voluntarily attending one of 48 testing sites during 6-29 November 2020. Interventions Participants were tested using both an Innova LFT and a quantitative reverse-transcriptase polymerase chain reaction (RT-qPCR) test based on supervised self-administered swabbing at testing sites. Main outcome measures Sensitivity, specificity, and predictive values of LFT compared with RT-qPCR in an epidemic steady state of covid-19 among adults with no classic symptoms of the disease. Results Of 5869 test results, 22 (0.4%) LFT results and 343 (5.8%) RT-qPCR results were void (that is, when the control line fails to appear within 30 minutes). Excluding the void results, the LFT versus RT-qPCR showed a sensitivity of 40.0% (95% confidence interval 28.5% to 52.4%; 28/70), specificity of 99.9% (99.8% to 99.99%; 5431/5434), positive predictive value of 90.3% (74.2% to 98.0%; 28/31), and negative predictive value of 99.2% (99.0% to 99.4%; 5431/5473). When the void samples were assumed to be negative, a sensitivity was observed for LFT of 37.8% (26.8% to 49.9%; 28/74), specificity of 99.6% (99.4% to 99.8%; 5431/5452), positive predictive value of 84.8% (68.1% to 94.9%; 28/33), and negative predictive value of 93.4% (92.7% to 94.0%; 5431/5814). The sensitivity in participants with an RT-qPCR cycle threshold (Ct) of <18.3 (approximate viral loads >10 6 RNA copies/mL) was 90.9% (58.7% to 99.8%; 10/11), a Ct of <24.4 (>10 4 RNA copies/mL) was 69.4% (51.9% to 83.7%; 25/36), and a Ct of >24.4 (<10 4 RNA copies/mL) was 9.7% (1.9% to 23.7%; 3/34). LFT is likely to detect at least three fifths and at most 998 in every 1000 people with a positive RT-qPCR test result with high viral load. Conclusions The Innova LFT can be useful for identifying infections among adults who report no symptoms of covid-19, particularly those with high viral load who are more likely to infect others. The number of asymptomatic adults with lower Ct (indicating higher viral load) missed by LFT, although small, should be considered when using single LFT in high consequence settings. Clear and accurate communication with the public about how to interpret test results is important, given the chance of missing some cases, even at high viral loads. Further research is needed to understand how infectiousness is reflected in the viral antigen shedding detected by LFT versus the viral loads approximated by RT-qPCR.


2016 ◽  
Vol 4 (2) ◽  
pp. 264-270 ◽  
Author(s):  
Aml Soliman ◽  
Asmaa Abdel Aal ◽  
Reham Afify ◽  
Noha Ibrahim

AIM: Aim was to detect Brain and Acute Leukemia, Cytoplasmic (BAALC) and ETS-related gene (ERG) expression in patients with acute myeloid leukemia (AML) as well as to study their biologic and prognostic impact on the disease outcome and survival.PATIENTS AND METHODS: The current study was carried out on 44 patients with denovo acute myeloid leukemia, as well as 44 age and sex matched controls. The quantitative real-time reverse transcription-polymerase chain reaction (RT-PCR) assay was performed for estimation of BAALC and ERG expression.RESULTS: The current study was carried out on 44 patients with denovo acute myeloid leukemia, as well as 44 age and sex matched controls. The quantitative real-time reverse transcription-polymerase chain reaction (RT-PCR) assay was performed for estimation of BAALC and ERG expression. BAALC was expressed in 36 (81.82%) of AML cases versus 10 (22.72%) of the control group which was highly statistically significant (P < 0.001). While ERG was positive in 39(88.64%) of cases and 8(18.18 %) of controls and that was also highly statistically significant (P < 0.001).CONCLUSION: Further researches still needed to clarify the role of BAALC and ERG in the pathogenesis of leukemia and their importance as targets for treatment of AML.


Sign in / Sign up

Export Citation Format

Share Document