scholarly journals Antenna polarimetric calibration using multi-mode TRL calibration method and its extension

Author(s):  
Hsin-Chia Lu ◽  
Tah-Hsiung Chu
2021 ◽  
Vol 88 (s1) ◽  
pp. s34-s36
Author(s):  
Lars Grüter ◽  
Richard Nauber ◽  
Jürgen Czarske

Abstract Strong acoustical aberrations such as induced by multi-mode waveguides or the human skull can significantly reduce the quality of or prevent effective ultrasoundbased imaging. We propose a novel non-invasive calibration method that utilizes two independent acoustical accesses and a time reversal virtual array (TRVA) for adaptive wavefront correction. Numerical characterization and a model experiment utilizing this method show an improvement of the lateral resolution and the peak to background ratio by up to 35% and 10% respectively.


2018 ◽  
Vol 10 (12) ◽  
pp. 2060 ◽  
Author(s):  
Yoon Jung ◽  
Sang-Eun Park

In the diverse applications of polarimetric Synthetic Aperture Radar (SAR) systems, it is a crucial to conduct polarimetric calibration, which aims to remove the radar system distortion effects prior to utilizing polarimetric SAR observations. The objective of this study is to evaluate the performance of different polarimetric calibration methods. Two widely used methods, the Van Zyl and Quegan methods, and one recently proposed method, such as the Villa method, have been selected among various calibration methods in literature. The selected methods have basic differences in their assumptions that are applied to the polarimetric system model. In order to evaluate the calibration performances under different system parameters and ground characteristics, comparative analysis of the calibration results were conducted on synthetic polarimetric SAR data and ALOS PALSAR quad-pol mode data. Based on the experimental results, the advantages and limitations of different methods were clarified, and a simple hybrid calibration method is presented to further improve the polarimetric calibration performance.


Author(s):  
E. D. Salmon ◽  
J. C. Waters ◽  
C. Waterman-Storer

We have developed a multi-mode digital imaging system which acquires images with a cooled CCD camera (Figure 1). A multiple band pass dichromatic mirror and robotically controlled filter wheels provide wavelength selection for epi-fluorescence. Shutters select illumination either by epi-fluorescence or by transmitted light for phase contrast or DIC. Many of our experiments involve investigations of spindle assembly dynamics and chromosome movements in live cells or unfixed reconstituted preparations in vitro in which photodamage and phototoxicity are major concerns. As a consequence, a major factor in the design was optical efficiency: achieving the highest image quality with the least number of illumination photons. This principle applies to both epi-fluorescence and transmitted light imaging modes. In living cells and extracts, microtubules are visualized using X-rhodamine labeled tubulin. Photoactivation of C2CF-fluorescein labeled tubulin is used to locally mark microtubules in studies of microtubule dynamics and translocation. Chromosomes are labeled with DAPI or Hoechst DNA intercalating dyes.


Sign in / Sign up

Export Citation Format

Share Document