scholarly journals Mechanomyography Based Closed-Loop Functional Electrical Stimulation Cycling System

Author(s):  
Billy Woods ◽  
Mahendran Subramanian ◽  
Ali Shafti ◽  
A. Aldo Faisal
2005 ◽  
Vol 17 (01) ◽  
pp. 19-26 ◽  
Author(s):  
CHENG-LIANG LIU ◽  
CHUNG-HUANG YU ◽  
SHIH-CHING CHEN ◽  
CHANG-HUNG CHEN

Functional electrical stimulation (FES) is a method for restoring the functional movements of paraplegic or patients with spinal cord injuries. However, the selection of parameters that control the restoration of standing up and sitting functions has not been extensively investigated. This work provides a method for choosing the four main items involved in evaluating the strategies for sit-stand-sit movements with the aid of a modified walker. The control method uses the arm-supported force and the angles of the legs as feedback signals to change the intensity of the electrical stimulation of the leg muscles. The control parameters, Ki and Kp, are vary for different control strategies. Four items are collected through questionnaires and used for evaluation. They are the maximum reactions of the two hands, the average reaction of the two hands, largest absolute angular velocity of the knee joints, and the sit-stand-sit duration time. The experimental data are normalized to facilitate comparison. Weighting factors are obtained and analyzed from questionnaires answered by experts and are added to evaluation process for manipulation. The results show that the best strategy is the closed-loop control with parameters Ki=0.5 and Kp=0.


Author(s):  
Yuu HASEGAWA ◽  
Tomoya KITAMURA ◽  
Hiroto MIZOGUCHI ◽  
Naoto MIZUKAMI ◽  
Sho SAKAINO ◽  
...  

2014 ◽  
Vol 2014 ◽  
pp. 1-8 ◽  
Author(s):  
John F. Tan ◽  
Kei Masani ◽  
Albert H. Vette ◽  
José Zariffa ◽  
Mark Robinson ◽  
...  

The restoration of arm-free standing in individuals with paraplegia can be facilitated via functional electrical stimulation (FES). In developing adequate control strategies for FES systems, it remains challenging to test the performance of a particular control scheme on human subjects. In this study, we propose a testing platform for developing effective control strategies for a closed-loop FES system for standing. The Inverted Pendulum Standing Apparatus (IPSA) is a mechanical inverted pendulum, whose angular position is determined by the subject’s ankle joint angle as controlled by the FES system while having the subject’s body fixed in a standing frame. This approach provides a setup that is safe, prevents falling, and enables a research and design team to rigorously test various closed-loop controlled FES systems applied to the ankle joints. To demonstrate the feasibility of using the IPSA, we conducted a case series that employed the device for studying FES closed-loop controllers for regulating ankle joint kinematics during standing. The utilized FES system stimulated, in able-bodied volunteers, the plantarflexors as they prevent toppling during standing. Four different conditions were compared, and we were able to show unique performance of each condition using the IPSA. We concluded that the IPSA is a useful tool for developing and testing closed-loop controlled FES systems for regulating ankle joint position during standing.


Author(s):  
Jetsada Arnin ◽  
Traisak Yamsa-ard ◽  
Preechapawan Triponyuwasin ◽  
Yodchanan Wongsawat

The purpose of this study was to develop a functional electrical stimulation (FES) system based on the motor driving concept for use by spinal cord injury patients participating in the FES Cycling competition at the Cybathlon 2016. The proposed FES system consists of a low-power control system, a precise processor unit, and a 4-channel stimulation unit. Self-adhesive carbon conductive electrodes were utilized for stimulation. A 26-year-old SCI patient was qualified to participate in the competition. The pilot patient underwent training for 16 months, which included experience with FES stimulation, performing FES cycling, and reducing spasticity, to practice using the FES system. In addition, using surface electromyography (EMG) during cycling, the muscle activation pattern for generating the stimulation profile was applied and resulted in good performance. The best FES cycling performance the pilot achieved was 1000 meters translation with the cycling system during twelve minutes of using the FES system. The pilot achieved an 1000 meters translation mobility within an average of 16 minutes of cycling. Nevertheless, the system must be further investigated regarding muscle fatigue and other factors that may affect the stimulation conditions.


Sign in / Sign up

Export Citation Format

Share Document