Study on Reactive Power Compensation Effect on the Reliability of Power Supply Systems Operation at “Bulmarket DM” Ltd

Author(s):  
Hristian Panchev ◽  
Roberto Panchev ◽  
Vladimir Chikov ◽  
Rumen Kirov
2020 ◽  
Vol 174 ◽  
pp. 03026
Author(s):  
Fedor Nepsha ◽  
Vyacheslav Voronin ◽  
Roman Belyaevsky ◽  
Vladimir Efremenko ◽  
Kirill Varnavskiy

In this article, the authors discuss the use of FACTS devices in coal mine power systems. The problems of reactive power compensation and the disadvantages of regulatory and technical documentation regarding the use of modern reactive power compensation devices are considered. The main types of FACTS devices that can be used in coal mines are identified. The scientific publications in the field of application of FACTS devices in power supply systems of industrial enterprises are analyzed. The cost indicators of FACTS devices are considered and conclusions are drawn on the theoretical technical and economic efficiency of using FACTS devices in mine conditions.


2017 ◽  
Vol 4 ◽  
pp. 39-42
Author(s):  
Valery Avanesov ◽  
Musa Didanov ◽  
Alexandr Scherenko

2022 ◽  
Vol 1 (15) ◽  
pp. 22-28
Author(s):  
Igor' Golovanov ◽  
Alena Alekseeva ◽  
Vladimir Proskuryakov ◽  
Roman Samchuk

Electrical circuits of reactive power compensation on the basis of thyristor control circuits in the power supply system of oil refineries are considered. The main advantages, advantages over traditional reactive power compensation systems and directions of introduction into the power supply system of modern production are formulated.


Author(s):  
E. I. Gracheva ◽  
A. N. Gorlov ◽  
Z. M. Shakurova

The article examines the main features of the layout of electrical equipment for shop networks of internal power supply with the definition of indicators for a group of shop customers connected to a single power center, affecting the choice of the structure of schemes for shop network sites. The parameters characterizing the circuit topology are revealed. A study is presented of the influence of the load factor of workshop transformers on their reactive power factor, it is proved by calculation by technical and economic criteria the feasibility of replacing a workshop transformer with two with a lower total power. The calculation of energy savings in the in-plant power supply systems. The type of dependences tgφ of transformers ТМ and ТСЗ with various rated powers in the function of loading transformers is established. The most significant factors of the growth of idle power losses during operation are presented. With determination of losses of active and reactive power and electricity in transformers and losses of active power in a high voltage distribution network A feasibility study was carried out on the options for internal power supply schemes with two transformers of lower power installed instead of one, and the feasibility of such a replacement to increase the efficiency of the equipment was proved and the estimated payback period for the investment capital was determined. A comparative analysis of the studied power supply schemes of industrial enterprises with the identification of their advantages and disadvantages.


2015 ◽  
pp. 29-33
Author(s):  
V. A. Kopyrin ◽  
V. A. Iordan ◽  
O. V. Smirnov

The authors provide a method for compensation of the reactive power inside a well. In the environment Matlab/ Simylink a model was developed of the site of the electrical centrifugal pump unit power supply from the transformer substation. A comparison is made of the proposed method of downhole reactive power compensation with the existing method.


2019 ◽  
Vol 110 ◽  
pp. 01010
Author(s):  
Vasiliy Cheremisin ◽  
Andrey Nikonov

The article presents a method for selecting the parameters of the current-voltage characteristics of adjustable reactive power compensation devices used at sectioning stations of railway sections electrified by alternating current with a voltage of 27.5 kV. This technique is based on the experience of operating two types of devices in the traction power supply system. Power control of these devices is implemented by the voltage level at the switching point. Selection of the setpoint voltage and slope characteristics was done. The developed method allows increasing the efficiency of devices by eliminating the voltage losses on the active component of traction loads. That will reduce the loss of electricity in the system of traction power supply. Changing the parameters of the characteristics will increase the relationship between the reactive power consumed in the zone and the voltage measured by the devices. Following the results of the formation of the methodology, an example of the choice of characteristics for a real compensation device is presented.


2019 ◽  
Vol 146 ◽  
pp. 714-718
Author(s):  
Claus-Peter Käsemann ◽  
Igor Goldstein ◽  
Christian Jacob ◽  
Michael Rott ◽  
Michael Schandrul

Sign in / Sign up

Export Citation Format

Share Document